waste pipe | Page 3

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

waste pipe

  1. A

    NIBE f205 waste water constantly flowing down the waste pipe

    Out Heating system is losing water constantly. I believe it's overflowing from somewhere and is flowing into the waste water funnel and from there straight into the waste pipe. Apart from receiving a very large water bill it's preventing the system from reaching the 50 degrees idol temperature...
  2. N

    Kitchen waste pipe replacement costs

    Hi, a plumber has been out to my rental property as my tenant reported a blockage causing water to flow back from the washing machine into the dish washer. Both were disconnected and their drainage hoses cleared out but the plumber advises that there is more of a blockage further down the waste...
  3. P

    Leaking sink waste pipe replacement?

    Hi, the waste pipe under the sink is leaking at the push fit connection. Is there an easy way to seal, or should I replace with a compression fitting? Leak in yellow circle in grey pipe. Thanks
  4. P

    Fall rate in waste pipe

    Hope someone can help, currently have a new build property (was Kier now Tilia) 18 months old and it looks like there is no fall rate between the cloakroom toilet and the vertical waste pipe. I have checked with a spirit level and the pipe is level. Feel free to advise on whether there should...
  5. S

    Shower tray waste pipe fitting

    I am really struggling with how to do the waste pipework from a shower tray and would appreciate any advice on the best approach to take. The tray will be sitting in a three sided recess which really complicates things. A further complication is that the soil pipe is very close by and so there...
  6. R

    Waste pipe blockage because of drop?

    Hi, I'm not a plumber so I need some info/advice... I recently renovated a bungalow, which has all gone well and isn't the problem, but since moving in our drains block. The first time severn Trent came out and unblocked them, but said they shouldn't really be doing it as its on our driveway...
  7. S

    waste pipe - minimum distance from stack?

    Im installing a wall hung toilet frame and just working out where everything needs to be positioned etc. I want to move the frame/toilet over to the right as far as possible but can anyone tell me if there is a minimum distance that should be used for a straight run before going into the...
  8. X

    URGENT New flush and waste pipe issues

    I have just bought a new flush for my cistern as the old had broken however upon fitting, the new flush outlet is the same width as the pipe leading to the toilet and im struggling finding a way of connecting them. Can I just have someone tell me there is some sort of fitting or adapter I can...
  9. D

    22mm speedfit to waste pipe???

    I'm installing a waste pump in wet zone area(ground floor concrete) Waste pump has 22mm feeds which I would normally connect to soil pipe with boss strap. However the soil pipe is clay embedded in concrete with a 90° pan connector going straight into the ground. I've seen the pan conns with...
  10. dilligaf

    What size bottle trap for bathroom basin with a O/D 36mm waste pipe?

    Can anyone tell me what size bottle trap for the basin in the bathroom for a 36mm O/D waste pipe? Most bottle traps seem to be listed as 32mm or 40mm?
  11. J

    Solvent Weld vs compression waste pipe

    Does anyone have a preference to use solvent weld or compression fittings for waste pipes?
  12. 0

    Is my neighbours soil/waste pipe allowed to be over my driveway

    Hi, Im hoping someone could give me some advice please. I'm new to this site so please forgive me if I'm posting incorrectly or in the wrong place. I am looking for advice on my neighbours bathroom waste pipe. I'll try to explain this as best as I can. Our neighbours house is set forward from...
  13. C

    Advice on correct sized spigot to connect washing machine to waste pipe.

    Hi All, I recently moved house and the waste pipe in my new home is significantly smaller than my last. It measures 25mm. I am having trouble decifering which sized spigot to get and I'm also having trouble finding anything smaller than 35mm (which bought and is too big).Pics attached. Advice is...
  14. S

    50mm Waste pipe hole size

    What hole size would you recommend drilling for 50mm waste pipe that needs to go through a joist? Joist is 200 deep so a 55mm hole is already a bit over the recommended size for that joist.
  15. H

    Waste pipe size?

    Hello, I am looking to move some waste pipes in my house as I will be relocating a washing machine. My question is what size waste pipe do I have. I have measured with a gauge and get 56.08mm on the outer diameter. My understanding was the common sizes are 32, 40 and 50mm, I am aware there...
  16. M

    Dehumidifier in to waste pipe

    Is it acceptable to plumb the waste from a dehumidifier into to a waste pipe. It has a 9mm pipe with it for the waste. I was thinking of putting this on to an appliance connector waste Fitting then screwing onto a hepVo trap. A washing machine upstand maybe unadvisable incase it isn't used for a...
  17. M

    Long waste pipe run aav and or antivac trap

    I have a long waste pipe run that is out side of the recommended distance of 4 meters for 50mm pipe. It only has one appliance on it. But because of the length of the run I want to stop self syphonage of the trap. Is there any benefit of fitting a trap with and anti vac adapter or anti vac...
  18. S

    What are my options replacing toilet with waste pipe in floor?

    A few years ago I had to replace my old, 1960's downstairs loo as it had a crack in it. I was told that, because the waste pipe went down into a hole in the concrete floor and because of the distance of that hole from the back wall (20cm), I'd need a loo with a concealed cistern in a large...
  19. M

    Slightly moving waste pipe connection into soil pipe

    Parents have had a steel beam put into their hallway ceiling to adequately support landing and stairs. This means that the waste from a sink and shower will need to be reinstated slightly lower into the soil pipe, as the pipes will now run under rather than through the beams (the joists will be...
  20. S

    Blocked waste pipe - again

    posted up on here back in October about the waste pipe on a flat Ive got rented out being blocked.... That branch goes into a vertical stack, shared by the flat above and below. Back in october i had dyno rod take a look at it and they said the pipe was scaled up. They cleaned out the pipe...
Back