Hi all,
Recently moved into a new house and noticed the Greenstar boiler has low pressure on the dial.
Quick Google suggests using a key, valves, or fill loop to increase the pressure. Only problem being is I don't have either of those things.
Any help would be appreciated.
Cheers.
I need some help with a Worcester Junior 28i gas boiler and I'm hoping someone here may have came across this fault before ...
I have checked the following:
240v at supply connections
All internal push on connections are correctly fitted to the PCB board
The transformer is giving the correct...
Good afternoon everyone, I am hoping you may be able to help me. I have a Worcester Bosch 19/24CBI boiler and it keeps cycling. When trying to heat the hot water (same for heating) the boiler is off more than it is on and thus unless timed for a very long time never gets the desired outcome. In...
Hi,
I have the boiler as above which has been very good for the last 13 years or more and is still relatively going strong.
However, now, the secondary heat exchanger is kettling and the easiest option is to replace it.
Although Worcester Bosch do sell a cleaning kit, whatever route I take, I'll...
Condensing boiler installed by local Gas Safe plumber in 2014, not combi. Failed a couple of weeks ago with flashing blue light which googling suggests means no gas, blocked flue or blocked condensate pipe. There is gas, the flue is clear, and the condensate pipe goes into the under-sink waste...
Hi I have a Worcester MT10RF mechanical rf thermostat and it is broken dropped and all cogs dislodged leaving me confused how they put together. I have sat there for 3 hours straight working it out and still can't get it together even left with a orange peace that I have no clue were it goes...
Ive moved into a house with a worcester greenstar 35 HE plus boiler in the garage. The TR2 thermostat controller is hanging loose on the wall in the living room, and is faulty. I want the TR2 replaced with a controller i can set a timer on, either digital or mechanical, the TR2 has three wires...
I know there is a TB but I can’t seem to track it down.
If you analyse around a WB kebab and detect a low number of PPM is it AR or ID?
Assuming the case seal is intact and nothing detected around outer case?
To me it’s ID but on an ideal logic for example it’s acceptable as the gasket is porous
I presently have a Greenstar 24i junior installed, it's probably about 12 years old and getting cranky, the engineer suggested upgrading it to a 30 model sometime, but he just realised that the gas pipes would need changing (from 15mm to 22mm).
My question is, which model would you suggest...
Hi All,
I wonder if anyone could give me some advice regarding a Worcester 28cdi ii , I get hot water only at certain times when the central heating is on and even then the hot water is in short supply, there is a tank next to the boiler.
Is there a way of having hot water all time when needed...
Evening
Hopefully you're not sick of this type of question!
I've had a few quotes for a boiler upgrade (going from a regular boiler (~15 yrs old, on its last legs) to a combi) - all recommending different brand/model of boiler, and all company's are saying that their recommendation is the best...
HI All,
Weird problem with an FS30 CDI, The boiler does not come on when demand for heat (LR terminal) is on, but I can turn it on manually via the service menu. Heating controls all seem fine, but anyone seen an issue before where it doesn't seem to register the demand for heat and just stays...
Can anyone tell me if the greenstar 24i circulating pump modulates? i have been looking at param 2.1c which references settings 0 to 4, i know the factory default setting is 4 (constant high pressure) which to me implies that it would not modulate on this setting, does it need to be setting 0 to...
Hi All,
I have a Worcester Danesmoor 20/25 oil boiler which is causing me lots of heartache and grief. About 3 months ago it locked out and wouldn't fire up when reset so I called out the local (but recently retired) engineer to see what he thought. He thought it was the pump so he serviced the...
Heatslave 20/25 subtle humming from boiler new motor fitted fully serviced recently, it's the sort of sound you would get from a HV transformer that sort of hum deep and annoying, nothing to do with circulation pump it's still there with the circulation pump off. I guess it only leaves the oil...
Our boiler makes these very loud rumbling noises every 2-3 minutes. We're quite used to them now but they have become a lot more regular over the past year or so (it only used to happen once every half an hour or so) and they can be quite annoying. Our boiler is a Worcester Greenstar 24I Junior...
Hi all,
I'm due to change my first plate on a Worcester Greenstar next week (not looking forward to it).
I found this on Youtube. Is it really as easy as this guy says? And what about checking/replacing the O-rings?
Any tips most welcome.
Thanks
Jennie
Hi
I have an oil worcester bosch greenstar heatslave ii combi boiler. It's about 5 years old.
The problem I have is when the thermostat calls for the central heating to come on. Most of the time the boiler light will come on, the boiler might fire up for a couple of seconds then the light will...
Vaillant boiler was decommissioned last week due to faulty flue, parts no longer available.
Heating engineer suggests: Worcester Greenstar 8000 life 30kw system boiler with horizontal flue and Worcester
magnetic filter. This sounds ideal, but he can't source it due to shortages so has suggested...
A customer rang this morning, says they have a intermittent fault on the boiler P3. Its a Worcester CDI30 I think from a past visit. I did quote for a new boiler 10 months ago, but the old one is still hanging in there. I looked on line as I don't have the book with me. Any suggestions? He says...