worm | Page 9
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

worm

  1. P

    Glow worm Hideaway 100 floor mounted boiler wanted.

    HIDEAWAY 100 FS Boiler wanted Please
  2. U

    Glow worm Hideaway 100 floor mounted boiler wanted

    Has anyone got a Glow worm hideaway boiler 100 for sale The one we have is about twenty years old floor standing There is water leaking from the heat exchange and needs replacing either with spare parts or a complete new boiler.
  3. J

    Glow Worm Hideaway 60B FF fails to ignite Auto ignition

    Hi everyone, I have the said boiler and although it attempts to fire up, it doesn't! I have replaced the PCB to eliminate problems there and it still tries to fire. I have a gas supply but not checked the jet. The 2 LEDs flash 4 times and it tries again. Blocked jet?? Any ideas guys (and gals)?
  4. S

    Glow worm 18hxi overheating high limit cuts in but display reads 35o

    High limit cuts in with f5 but display reads 35oC Replaced flow/return thermistors but still the same flow temp gets to about 87oC Differentials about 9oC on hot water Any ideas?
  5. J

    Glow worm Betacom 30 c

    Anyone have any experience repair these boilers? No lights on display so changed interface board. Same issue so assumed it's was the PCB. Have now changed both the interface board and PCB and still nothing on display. Before anyone asks there is 230 V to the board
  6. M

    Glow worm boiler

    I have a 2 year old glow worm boiler which was installed in new build home. At the side of my house there is a plastic vent from the boiler and then further along the wall say 2 metres there is a copper pipe. A few months ago I noticed the pipe had a steady drip and the ground underneath was...
  7. F

    Glow worm Ultracom 30cxi Plate Heat ex

    Hi Everyone, I'm replacing a plate heat ex for a glow worm 30 cxi tomorrow, I've just had a look at the boiler now and at first glance it seems I'd have to take out the burner assembly etc to do the plate heat ex swap as it's located right at the back. Is there an obvious easier way that I...
  8. R

    Glow worm 30cxi pain!!!

    Went to the job Thursday and changed the sani block (ie diverter) on a 30cxi as the old one was losing heat into the central heating. When it was all striped down there was a lot of muck in the plate to plate cleaned that too. Got it all back together lots of hot water turned off the tap and the...
  9. S

    Glow Worm Ultracom 24HXI - Electrical Connections

    My plumber is away on holiday so cannot be consulted. He is fitting a Glow Worm Ultracom 24HXI for me when he returns. I want to chase in the cabling to the boiler before he starts. Please can someone advise where the electrical connections connect on this boiler. Top, bottom, left, right...
  10. S

    Vaillant and Glow worm flues

    Are the vertical terminals for glow worm and Vaillant the same / interchangeable? Does using one brand with the other constitute a breach of Mi's or regs?
  11. M

    Glow worm Betacom 30 free for spares

    Hi, I have a complete Glow worm Betacom 30 Condensing boiler, it is in fully working order but was removed due to a refurbishment. I need to clear some space and already have enough other boilers for spares. Any one interested or it will go to the tip. It must be collect from just outside...
  12. A

    glow worm 85 -100 need gas valve

    Thanks can any one help in sourcing this gas valve for this old boiler? Or if anyone can repair it...has a slight leak.I can mail picture if it helps Tha
  13. R

    glow worm leaky

    took a look at this boiler today (gw 30cxi) with the report of a drip coming out of it. its not that bad at the moment but upon running the heating for 20 mins the cold static pressure was at 1.1bar then reached 2.4 bar which i thought a bit high!! in the photo you can see the scale on the...
  14. T

    Glow worm betacom 30c dhw running hot then cold

    My booler is running hot then cold, it's been doing it for a wile but it's the old story I'll fix other peoples but not my own, well now it's stupid and needs doing. Dhw gets to a good temperature but then drops then picks up again i changed the hot water flow switch last year and the onset of...
  15. U

    Noisy glow worm ultimate 40FF boiler

    My boiler has recently started making this annoying noise. Seems to be in a working condition but to me it just looks like boiler about to break. https://youtu.be/sRR7BW8GZVk this is the link to the video I uploaded of my noisy boiler. Anyone got any idea what is faulty?? Any help would be...
  16. K

    Glow Worm 30 CXI F13

    Got called out yesterday to this one, asked over the phone if there was a fault code and F13 was showing, She said previous engineer had been out twice and pulled connections on the board, puts back together works for a short while but locks out with the F13 again. Picked up a new board on way...
  17. D

    glow worm 30cix

    Hi can some one tell me can I ditch the programmer and just use a thermostat to control this boiler.
  18. C

    G/Worm 30Ci filling loop is different to existing. Will it fit?

    I have been to fit a new dis-connector to a 30ci part number 2000802600. it doesn't look anything like the existing filling loop. The original dis-connector was 2000801908 but is now obsolete. Has anyone fitted the new loop to one of these boilers. Thanks for any advice. casaco
  19. Scott_D

    Anyone fitting Glow worm combis?

    Anyone fitting Glow worm combis? I need a cheaper alternative to put on a quote with a Vaillant 824 Was looking at the Flexicom and Ultracom-2 Good, bad or average? It can't be an Ideal as it's to replace an Isar It must have a 15mm gas connection or the new kitchen will need to be butchered
  20. R

    glow worm 24cxi on all the time

    Now its warmer i have just noticed that the boiler is on all the time even when the room stat is off. its only heating rads luke warm. when room stat is on rads go hot as it should do. Reading the manual it says that at 3 degrees the boiler will be on tick over and go off at 10 degrees (frost...
Back
Top