burner

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

burner

  1. Inverness

    Advice on replacing with a new riello burner

    im looking to replace this burner but is this easily done with a new modern riello burner or would you recommend replace with like to like? I hate these shutter manual fan.. I would prefer to replace with the new riello burner if possible but the firebird boiler has a latch case that can't be...
  2. Meady

    Connecting log burner to heating/hot water

    A mate of mine has bought a bungalow which is a complete strip back and start again job. He wants to get a log burner that he can tie into the hot water/heating, but keep a gas boiler for when the fire isn't on. Is this possible, and if it is what system/set up and controls are needed. This...
  3. Garroth

    GlowWorm Boiler Burner Never Switches Off

    Hi, whenever my Gloworm 18r is on even if I leave it on non-stop for 6 hours the flame symbol for the burner never switches off and the radiator icon never stops flashing implying the rads are calling for more heat, even though they're all red hot and have been for hours, is this a fault or just...
  4. M

    Worcester Greenstar 24RI - Burner Seal Replacment

    Got some quotes for a service, one person has said if I haven't had the burner seal replaced for past 5 years, it should be done (& service price goes up by £55). Boiler installed in 2015 - never had the 'seal' replaced? Is it a necessary requirement just as a matter of course?
  5. G

    Is my gas burner an FSD problem or a thermocouple problem?

    I am troubleshooting a gas hob where one burner is reluctant to light. When it is lit and I blow the flame out the FSD on that burner cuts off immediately, whereas the others take 5-10 seconds as normal. I have tested the thermoucouple for continuity and also some sort of mV output (when held...
  6. F

    Wood Burner back boiler with gravity rad system.

    Hi All...thx for the help in advance. I have recently installed a wood burner with back boiler heating system. Set up with gravity rad and header tank in loft. I have a recirculation pump installed that I have connected to the rad system that I turn on and off manually. I wanted to know how...
  7. J

    URGENT Riello 40 burner not firing

    Evening, My son's Riello 40 burner keeps going into reset. Oil is definitely there, fan is working, 240v at control box, tried about 10 times without success. Looking for advice as they have a 2 Yr old and need to get the heating going. MTIA
  8. J

    Trianco Eurostar 50 - 60 (S) oil burner riello motor problem

    I'm looking for some advice on a frustrating problem I'm having with my old Eurostar 50-60s oil boiler please? Although it's old, most parts needed to operate it are now new. The symptoms indicated a broken/seized burner motor or oil pump. I wrongly assumed the motor so I ordered a new one only...
  9. K

    One burner on gas hob not working

    How would you classify this for a LL cert?
  10. S

    Trianco burner locking out

    I have a customers trianco burner that starts from cold ok for a few minutes (say 3minutes) then locks out then will not stay on. Boiler had not been serviced in a long time and oil filters were bunged up as was the nozzle. I decided to service it with hopes it was simple starving of fuel from...
  11. P

    Worcester greenstar compact 30Ri burner.

    My Worcester greenstar compact burner green light is only firing up for 5 seconds then cutting out. Anyone got any ideas before I call an engineer out. Incase it’s something simple.
  12. B

    Grant / Riello burner choice

    I have a Grant Vortex Blue 26kw external oil boiler, installed less than 12 months ago. It's had intermittent non-starting problems resulting in multiple warranty visits, part replacements and eventually burner replacement. The replaced burner I discovered was a 'yellow flame' one, apparently...
  13. J

    Heatslave 20/25 lockout not control unit or burner

    Hello!! I’ve got an old heatslave 20/25 running on kerosene. Came up with a lockout today. Tested everything I could. Symptoms, blower not starting. But… The burner runs and the boiler works if I bypass the “back to mainboard” loop for the blower motor live. To be specific, pin 4 pink wire from...
  14. Nicjones

    Riello 2.2 rgb oil burner won’t start

    Hello all Our riello burner intermittently won’t ignite. However for some reason when you tap gently the oil pump it lights every time. Any help appreciated. Thank you
  15. A

    Gloworm faulty boiler, flashing burner & reset lights & buzzing

    Gloworm FF50 both the reset and burner lights are flashing and just buzzing, not firing up. Currently no hot water or heating, everything was working ok earlier today, then just suddenly stopped.
  16. M

    Danesmoor 12-18 riello RDB burner can it use 35 sec low sulphur diesel

    I have just bought a Danesmoor greenstar12-18, fitted with Reillo RBD burner. Worcester notes should be used with C2 Kerosene, is it possible to run on 35 sec low sulphur diesel instead? Any advice is very much appreciated thank you.
  17. C

    Combi boiler into existing wood burner system

    My parents house has a wood burning stove that is also connected to the central heating ( they have radiators and used to have an old boiler which they took out and replaced with the wood burner ) so the wood burner can also heat water which can then be pumped round the rads and works fine when...
  18. N

    Overheat protection for a wood burner with back boiler install?

    Hey guys, I've searched the forum, but haven't found anything useful. I don't know the name of the thing I'm looking for, so I apologize in advance if this is something basic that I should have found in a search. So basically, my electrician is an old fella who doesn't know much about heating...
  19. L

    Drigging oil from burner

    Camray 5 (90A) (20 year old) oil boiler, had a noisy fan on the boiler so investigated, just a bit of dirt in the casing however, having removed the burner unit I replaced the Burner Nozzle no problem, old was very dirty and sooty. Found the boiler wouldn't fire up. SO rather than than mess...
  20. L

    Camray 5 leaking oil from Burner Nozzle

    Camray 5 (90A) (20 year old) oil boiler, had a noisy fan on the boiler so investigated, just a bit of dirt in the casing however, having removed the burner unit I replaced the Burner Nozzle no problem, old was very dirty and sooty. Found the boiler wouldn't fire up. SO rather than than mess...
Back
Top