Hi me and my partner have just moved into a new house and the boiler was working fine last night on our first night however I have woken up this morning to the unit being completely off not even showing the stand by display or the blue light, I have adjusted the thermostat and turned the unit...
Hi A Vokera Compact 28 With a low pressure problem.
If the CH standing pressure is set any higher than 0.2 bar, at full temp the PRV operates and Blows down until 3 bar
and then when it cools locks out on low pressure.
The Boilers 6 years old and due service in august Last service sheet says...
Hi guys went and piped up a compact CDI today, first day doing one of these and was impressed with it. Was having a nosy around it because i'll be back there Monday to finish off the install. There was a block with 2 blue wires coming out of it that was hanging loose and i couldn't see another...
Just before Xmas the boiler locked its self out (red light). Loosing pressure recharging a few times a day.Reset boiler as per instructions. Done it again. Reset called landlord sent engineer out. He reset system and said nothing wrong. Ring if it goes over 3 bar.......
Air in rads bled...
Hi guys,
Had a landlords cert this morning for a empty rental property, biasi riva compact he 28. The combustion reading where Co ppm: 1170, co2% 8.8, ratio : 0.0132.
Will be doing a full strip down service and adjusting the min max gas pressure at valve. Would this be enough to bring...
Hello all, new member and I am hoping someone can help me.
Would anyone have a wiring diagram for a Heatline S30 printed circuit board. I have a failed boiler and having checked the pcb all 240v circuits appear OK, but the low voltage has no output from the transformer. The manufacturers site is...
I've fitted a few of these now and had a few call backs with leaks. Anyone else had problems with these and which magnetic filter is the most reliable.......
Can anyone tell me if you can run all 5 pipes behind for upward piping on this model?
From the MI's it doesnt show the gas, just F&R H&C
Also does it have the key type filling link?
:santa3:
Hi,
I have the above boiler which is around 4 years old. Recently it has started giving me a number of problems and unsure if they are all related.
I now have these problems:
1. Despite the heating regulating dial being on very low the water is scalding out of the tap. However on...
Hi all,
called to look at a Vokera compact Se (2005)where there was water constantly filling from the domestic hot water over pressurising the boiler. Checked expansion vessel and ok. I can't see any divertor valve, so am I right in thinking that there is a leak in the heat exchanger between the...
Hi
all attended boiler flashing red/green call vokera stated faulty thermistor , replaced turned on no led at all. turned power of checked internal fuse ok turned power back on nothing off again left 30 sec tuned on fired up green light. landlord called tenant said gone off no led light so...
I have re-ordered a NK one compact soft close seat as the old one had broken (for NK compact WC set - free standing), the new seat is a slightly updated model with different hinges and fixing pins.
I need to get the old fixing pins out of the toilet itself but when I unscrew them there is...
Alreet ladies. After one tissue to the neXt. Went to compact 35he
Ratio 0.0082
CO 408
Co2 5
Burner 10.2
Inlet 10.2
Was diagnosed by service guy. I just fitted Venturi and then carried out checks, she were rough!
Clean side fine. So all I can think is that the gas valve been fully opened...
I have a problem with Vokera Compact 25he combi boiler. I'm registered gas engineer. When I came there first time I noticed that the boiler can't start because of air pressure switch. I checked that and it is ok. Replaced fan, cleaned vonturi then, so the boiler started ok on hot water and...
hi im new to the site and don't do many boiler repairs just mainly installs, would like some advice on a problem I was asked to look at for a family friend, the boiler works fine on heating but when hot water is running after about 5 min the boiler goes out for a minute or so then re lights, any...
I'm fairly puzzled by this one chaps, it's the compact with the secondary heat exchanger that the fan blows through. It seems that condensate is running down passed the fan in in to the bottom of the burner chamber.. initial brief investigation seems to be pretty clear combustion air path and...
I'm having problems with this boiler. The diverter valve won't move at all. I have fitted a new div valve today, no change....
I have also changed the flow switch (on top of water valve). I have checked as best I can the capillary tubes and the pump seems strong.
I just can't get the flipping...
alright guys am not for one fitting viessman, I have had this in my unit for 8-10 months brand spanking new boiler (5 YEARS) the box is not the best but still holds the boiler fine, Nothing missing full boiler I am looking to get rid of it cheap as it sat in the garage doing nothing and I just...