compact | Page 4

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

compact

  1. S

    Glow Worm Compact 60 boiler leak created whilst fitting a Magnatec

    I'm a fairly proficient DIYer and was fitting a ADEY Magnatec to my daughters central heating system, connecting it to the return flow beneath the boiler (recommended as the ideal position in the instructions). In order to install I needed to slightly modify the pipework to allow sufficient...
  2. Scott_D

    WB CDI compact and SI compact

    Is it the same boiler internally? Need to fit a boiler in a kitchen cupboard
  3. hammers4spanner

    Worcester compact

    What do you lot make of this boiler ? Fitted first one today not sure if the service panel was just flimsy pap or it was me not being use to it .The flue turret connections were very flimsy as well screwing the turret down sheared off the connection underneath very easy . They normally like this??
  4. T

    Vokera Compact A red light

    Hi, hoping someone can shed some light on this. After running a shower for more around 30 mins my four year old Vokera compact 29A locks out to a continuous red light (but only after switching off the shower, not during the shower). After a few hours and several attempts to reset at mains switch...
  5. Gasmk1

    vokera compact 35HE

    how stupid of a manufacturer to make a boiler with a condensate pipe made of metal that feeds from heat ex to condensate trap, have ordered new one which surprise surprise is made of plastic.
  6. C

    Vokera Compact 25 ignition failure (can anyone help a rookie)

    Hi Guys New to the boiler diagnostics, so go easy http://www.vokera.co.uk/wp-content/uploads/2014/02/Compact_A_User_and_Install_Manual-v1.pdf Carried out initial electrical safety test.. Earth resistance, Resistance to earth, Short circuit and polarity all ok. Put a hot water demand on the...
  7. L

    Worcester Compact - CDi or Si version?

    Looking for a really, really compact combi for a small 2 bed, 1 bathroom flat with very restricted kitchen space. Smallest decent one I can see is the Worcester Greenstar. By all means recommend alternatives, but 690x390x280 looks hard to better. I can't find any comparisons between the Si and...
  8. G

    vokera compact 25 he hot water problem

    Hi there I am having a problem with the hot water on the above boiler At first the hot water was running hot then cold hot then cold due to the boiler cutting off so I replaced the plate heat exchanger and the problem was solved. But now the water only runs lukewarm when the tap is run...
  9. S

    Vokera Compact 29HE Problems

    Before i wave the white flag, do we have experts on the dreaded Vokera Compact 29HE Combi Customer initially reported no heating or hot water I went to look at the boiler and it was dead, no pump or fan activity, then it just started working and did so until i left. Customer then reports the...
  10. J

    Vokera compact 24 has heating but cuts out on hot water

    Gotta go look at a vokera comact 24 this morning its an old stlye on with the twin pass hex. Heating works fine but when hot water it cuts out straight away. not come across this fault before. So was wondering if you guys had any ideas. thanks in advance
  11. A

    Worcester 32cdi compact combi boiler and Megaflow

    Hi there First post, so be gentle :90: We are renovating and extending our newly purchased house and it has a Worcester 32cdi compact combi boiler that is around 2 years old installed already. We are adding one bathroom (2 in total) and an additional toilet (2 in total) and we are putting in...
  12. L

    Compact combi boiler with back outlet flue ?

    Can anyone please tell me if a compact combi boiler exists with a back outlet flue ?. I have limited height externally under the gutter outside the bungalow wall to allow for a conventional top right angled flue Many thanks
  13. R

    Vokera compact 35 he problems.

    Can anyone help me with this. Was getting no heating and hot water. Spoke to Vokera and explained symptoms and they said clean Venturi which I did . The beige part at Venturi was broken which don't know if this is cause because boiler fired after a cleaned Venturi for about half an hour then...
  14. U

    Vokera Compact 29a pressure problems

    Hi. I have a Vokera Compact 29a which was installed new nearly 1 & half years ago. The last few months the pressure has been rising into the red and on occasion water leaking a little from left side when pressure too high. Have been bleeding radiators to reduce pressure and sometimes you hear...
  15. jaydebruyne

    Biasi Riva Compact M90E 24S

    I have to change the plate heat exchanger tomorrow and the MI's dont have any parts replacement help in the manual. Anyone got a parts replacement doc for this boiler??? Cheers
  16. J

    Vokera compact 25 ignition fault

    Hi guys. Just hoping someone could give me some ideas as to what could be causing problems with ignition on a compact 25 (g c no 47-364-01) The boiler seems to fail to ignite but is sparking and I can hear the gas ignite before going out and trying to spark again until it goes to lockout...
  17. spanner

    HEAT LIKE S24 Compact service HELP

    Hi guys posted this thread couple of days ago What's involved is a full service for this type of combi?, and it's not condensing just only "combi only"? Looking at the MI's only state how to remove cover and DHW, C/H fault mode! Was talking with the tech team at Vaillant on Monday and they've...
  18. spanner

    HEAT LINE S24 Compact losing pressure

    This is amazing. No leaks and losing pressure. charged up 0.8 bar yesterday. And down complete by the morning! And weren't doing so before and have no leaks in the system? Going back tomorrow to check the pressure as I've g it on dry test atm.
  19. spanner

    HEAT LINE S24 Compact extinguishing flame

    Got called yesterday over "boiler won't stay alight" Hasn't been serviced since fitted seven years,? Has to keep topping up with water every month? Looked all around at first and seems okay, Removed front cover to see a puddle of water below burner either from primary flow or back of grub key...
  20. spanner

    HEAT LIKE S24 Compact

    Got called yesterday over "boiler won't stay alight" Hasn't been serviced since fitted seven years,? Has to keep topping up with water every month? Looked all around at first and seems okay, Removed front cover to see a puddle of water below burner either from primary flow or back of grub key...