Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

condensate

  1. B

    How should condensate drain connection be made at top of downpipe?

    [ASIDE: I did wonder if this was the best forum for this but figured as it was a boiler related issue that the gas engineers would be dealing with it as a matter of course. If I'm wrong can someone let me know and I'll shift it to a better place.] I have a condensing boiler installation...
  2. back2thefuture1

    Boiler condensate pipe fitted behind plasterboard

    Hi everyone I hope you can help. We were getting some work done and our builder attached the boiler condensate pipe to the sink waste pipe. This was all then covered with dot and dab. Shown in the picture, red arrow. So the only thing visible now is a round pipe from the wall. We are yet to fit...
  3. T

    22mm Condensate Pipe Elbows Failing

    Our boiler is in the loft and I encountered a leak in a roof above our side extension store room which has transpired to be from the boiler condensate pipe. It was cracked at an elbow so the plumber we use has replaced this and hopefully all will be well with that joint. This later prompted me...
  4. B

    Boiler condensate pipe leaking at joint

    Hello I have a condensate pipe that appears to be leaking at the joint. How do I fix the leak? Would something like plumbers putty around the joint work or does it need to be some other compound? Can I simply pull the pipe and joint out and then put the compound round it Thanks
  5. J

    boiler condensate question

    hi. anyone used one of these before.. need to connect a hose from a condense pump to a w/c pan connector..these are for connection to soil pipe so im wandering if the wall of the pan connector maybe too thin?..best option is change pan connector to one with a boss on it but the toilet is stuck...
  6. Michael Groves

    Condensate Pipe installation

    Engineer has installed several boilers for me. All the condensate pipes have been connected externally into soil stack or rain water downpipe. In each case he just drilled a hole in the pipe, and stuck the condensate in the side, smeared glue everywhere. No boss, or branch. Is this allowed, is...
  7. M

    Condensate external or drill through from garage

    I'm on a new build the boiler is in the garage. I have the option of drilling straight out with the condensate in to the stack. Or drilling through from the garage to the house to tee in to the kitchen sink waste. So it's either coring out and coming out with that black dot is.
  8. exedon2

    Condensate waste thought's,?

    Picture of boiler with a 15 year service record by same company Thoughts on condensate waste?
  9. M

    Condensate Neutralising

    Hi all, new to the forum. Ive come across a commercial plant room with around 500KW of boilers where the condensate terminates outside about 4 inches under the ground directly next to the wall of the building...... no drain, no soak away, no neutraliser. My understanding is the acidic content...
  10. Scott_D

    Condensate pump questions ??

    I think I have only ever fitted 1 in my life. Got a combi swap to do in January fitting a Vaillant ecofit 830 and will need one Whats the best pump for reliability and low noise level? My merchant sells grundfoss and saniflo condensate pumps or do I stump up the extra and fit the vaillant...
  11. R

    32mm minimum size for external condensate - rule came in when?

    Hi. Was looking for a house on sale the other day and just wanted something confirmed to me... Was there ever a time when a condensing boiler could have been legally fitted, and in accordance with MIs, with a 22mm overflow used as an external condensate pipe... and with that condensate pipe...
  12. T

    Condensate pipe and position.

    Hi guys. My plumbers a nice guy and shortly going to fit new boiler. My concern is no obvious way to connect condensing pipe. No down pipes on my property or drains. He's considering letting it go to ground between two houses. I m not sure.!!. Dont think he has any alternatives. Any ideas or...
  13. D

    URGENT Baxi 105he condensate trap

    Baxi 105he fault code blocked condensate trap? Removed terminals disconnected the pipes undid fixings removed trap and gave it a good clean out then refitted? Boiler still showing same fault code after a lot of head scratching I changed the terminals over from there original positions on the...
  14. M

    URGENT Need to reroute condensate line to interior - ASAP

    Attic gas HVAC condensate line dumps into home's rear gutter, damaging it and fascia board. I need a Pro to re-route condensate pipe inside house ASAP for imminent roof replacement. Please message me your earliest availability and rates.
  15. J

    Boiler condensate into dedicated stand pipe - is it safe?

    I have read a few posts on here discussing sharing a washing machine stand pipe for the boiler condensate pipe and the risks of washing machine waste water backing up into the boiler etc., but I recently seen something that I can't find any discussion on so thought to start one. It was a combi...
  16. B

    Too much condensate flowing?

    I have noticed recently that when I switch on the boiler to heat hot water, the amount of condensate flowing is much more noticeable than usual, in fact, noticeable by the noise of the water running. Usually, you barely hear the condensate flowing. On the other hand, when the Central Heating is...
  17. S

    Boiler condensate colour

    Hi All New to the forum and would like some advice regarding flue gas condensate colour please. Carried out a repair this afternoon and checked flue gas . c02 in line with manufactures instructions and clean on the c0 side of things . Upon completion emptied my analyser trap and noticed the...
  18. A

    Recurrent e133 (not condensate related)

    Apologies if this has been answered elsewhere, but my family and I are starting to crack. I'll start at the beginning, and maybe someone will see something that makes sense to them. We live in a council property, and a couple of years ago our boiler (a Promax 28 Combi) started flashing us the...
  19. Scott_D

    External condensate pipework.

    I can’t find anything in black and white for this. I usually go through the wall in 40mm waste and don’t insulate. Does 40mm now need to be insulated as well as 30mm?
  20. O

    Central heating pressure is discharging through condensate trap.

    Hi everyone, my sister's 5 year old Worcester Greenstar CDi Classic boiler is losing pressure rapidly[down from 1.5bar to zero overnight]. I checked everything I can think of including all visible pipework, radiators and pressure relief valve outlet and couldn't find a thing out of the ordinary...