Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

condensate

  1. O

    Air break leak at condensate / washing machine waste connector

    Hello! DIY noob hear asking for advice on a leak from an air break. My undersink plumbing is a mess of pipes handling washing machine, dishwasher, and boiler condensate. When the washing machine runs, the air break overflows. The dishwasher is on too, the problem is worse. This used to happen...
  2. R

    Glowworm 30HXi condensate trap outflow speed

    Hi I inherited an LPG burning Glowworm 30HXi when I moved into my house some years ago. Great little boiler but had been neglected. I cleared a lot of debris out of the heat exchanger and chamber at base, on top of the condensate trap. I always flush several litres of water through the trap...
  3. A

    Condensate when the boiler is not running

    I’ve been having a few pressure drop issues with my heating system. One problem already diagnosed and sorted (thanks to this forum) was a leaking EV at the valve end (replaced) but I am still seeing a pressure drop (albeit slower than before 1.5 -1.4-1.3bar) and wanted to ask a question.... I...
  4. S

    How does a boiler sense the condensate pipe is blocked?

    How does a boiler sense the condensate pipe is blocked?. Boiler stopped working. I was told the condensate syphon was blocked and had to be cleared. I wondered how the boiler controls knew this?
  5. G

    Vaillant condensate into washing machine stand pipe

    hi, i have a 40mm boss connection at the top of a horizontal soil stack that runs in the room. I'm intending to put a washing machine stand pipe at the end of this. I also have a Vaillant ecotec pro 28 boiler next to where the washing machine will sit and was hoping to get the GSR to reroute...
  6. eagleeye

    condensate neutraliser

    I know that the condense from a boiler can only be terminated into a rainwater downpipe if its foul and rain combined but if its not and its easier and more tidy to run it into a separate rainwater downpipe is it OK to use a condensate neutraliser internally then run 32mm off of that to...
  7. L

    Condensate issues with Firebird boiler

    We have a Firebird oil boiler, 35kw and have recently started getting issues regarding condensate or lack of it. Long story as short as possible. Boiler running without any issues for 2 plus years, unusual smell from it turns out to be plastic condensate trap melted. Looked into problem and it's...
  8. MK03

    Condensate ph effects

    Hey guys and girls, Been a while since I posted in here, but I went on and bought the NVQ books and some tools and started doing the plumbing on the kitchens and bathrooms that I fitted, so learning more everyday. Plus the pro plumber I use has been very helpful showing me tricks and techniques...
  9. S

    Condensate pump and boiler off

    Hi, I have got a combi boiler with a condensate pump. I have found my boiler twice turned off electrically with the led display off. When I touched the pump the boiler turned on suddenly and the hot water started working again. Any ideas what could cause this? Thank you very much!
  10. A

    Veissman 101 boiler condensate.

    Hi all Is it normal for the flue outlet to be dripping water onto the outside drive and window sill when its running, i say no as the condensate should run back into the internal drain. Views much appreciated.
  11. J

    Can anyone help source a condensate trap

    Looking for Part Number 5106230. It's a condensate trap for a Potterton PowerMax boiler. Thanks
  12. M

    Boilers internal condensate trap

    Has anyone seen it become an issue where a boilers condensate pipe. Is tee'd in to a 40mm waste pipe that also takes say a sink waste. And the waste pipe pulling the trap out of the boiler as the sink discharges?
  13. M

    Vailliant pro 28 condensate

    Hey all. Can this be replaced without drawing and moving parts
  14. M

    Condensate trap on one year old boiler

    Any idea why the condensate trap on a one year old ideal boiler would have so much sediment in it as seen in the picture? On other one year old boilers of the same model on this estate the condensate trap is clear. In the one in the picture there is also sediment in the black pipe that connects...
  15. pmplum

    Condensate pump

    Hi Guys Looking for a condensate pump I can take the PRV into. Any recommendations ? Thanks
  16. A

    Steam condensate and Legionella...

    Can anyone advise on the chances of Legionella existing in the condensate pools from a Victorian steam engine, please? The pool temperatures range from cold to fresh steam condensate and they are very large, dirty and open to the atmosphere...
  17. S

    Re. "KOP"s recommendation for a condensate connector

    I can't put my finger on it now, but I saw a post where someone asked about connecting the condensate flexi from a boiler to fixed 19/21 overflow pipe. One reply was just to slide the flexi over the end of the fixed overflow but as I recall "KOP" recommended a McAlpine compression...
  18. K

    Condensate pipe termination

    Getting confused with how to route and terminate condensate pipes. My gas manual shows a diagram with the condensate pipe connected upstream of a washbasin trap. Baxi's manual does "not recommend", in caps, to connect upstream of the sink and its diagram shows the connection downstream of the...
  19. A

    Trying to pinpoint problem with boiler condensate pump

    Hi there, I am not a plumber, but wondered if any plumbers out there could help? My dad is also not a plumber by trade (although has plumbed plenty) and is a bit stuck with this one. Basically, there was a leak coming from underneath our floor-standing Worcester Greenstar CDi boiler, which...
  20. daWilko

    A Good Condensate Pump (?)

    Hi - the external condensate pump at home has died a death, leaving me with a little puddle. It seems quite an old one - labelled "Pro" - it's about shoe box size, holds maybe 2l. Tried cleaning it out, but alas no pressure from pump. If anyone has a recommended pump I'd be pleased to hear about...