Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

cylinder

  1. J

    Suitability of Unvented Cylinder

    Hi I've read through dozens of threads on here about unvented systems but was wondering if someone might provide some advice on an upgrade we are planning as part of a bathroom refurb Current Setup: Gravity fed system with cold water tank in the loft and hot water tank in the hot press (1st...
  2. C

    Removing cylinder and installing combi boiler. Pipe work query

    I have a question regarding combi boiler installation. I’ve just completed an attic bathroom where the previous plumber had put in the first fix of qualpex down to the airing cupboard which is standard practice. I’ve come a later stage to finish the bathroom but I now find that in the airiing...
  3. pufferfish91

    Unvented Cylinder Gushing Water from Relief Valve?

    Hi folks, I hope someone can help me. This morning we noticed water leaking under the hot water cylinder in hotpress room. On closer inspection, the water was just gushing on to the floor and it was only by chance we noticed it. We turned off the heating system and spent the morning emptying...
  4. O

    Unvented cylinder - usage question

    We have an unvented cylinder with a Horstmann Electronic 7 timer. The cylinder only serves a wet room which is very rarely used. The rest of the house is served by a Vaillant combi boiler. The timer on the cylinder is set to heat up water 3 times per 24 hours, which I think it is the default...
  5. G

    New Eco 7 Cylinder - spluttering/air in system?

    We've just had a new Economy 7 cylinder put in and after 3 or 4 days we still seems to get spluttering out of the taps as thought there is air in the system Basic setup as follows - apologies for poor terminology as i'm not a plumber! Cold water tank in loft of bungalow feeds into the hot water...
  6. W

    Water shut off cylinder

    Is it possible to replace inside part of the water shut off cylinder without replacing whole cylinder?
  7. R

    Advantage of unvented cylinder outweigh the disadvantages?

    I have come to my decision I might as well do my G3, even if only for maintenance jobs. Question I have is WHY we are fitting so many of these unvented cylinders i.e. 27 gallons /117l size or above (I'm not disputing the need for 10l unvented 'cylinders'). They 'need' annual servicing by a G3...
  8. R

    Do I need G3 to repair a 10l unvented cylinder?

    Hi. Potential customer has a leaking 10l Ariston Europrisma cylinder. Probably just a flange gasket or the magnesium anode needs replacing. While I feel this is easily the sort of task I can tackle as I am very good at mending things, I get the impression I'd need my G3 to install such a...
  9. P

    Cylinder noise / Balanced Colds / Pressure etc

    I wanted to start a new more dedicated thread as I am on about 3 just now in one way or another trying to get up to speed with my problem. The issue is that my Gledhill Stainless Lite indirect unvented cylinder makes loud noises when heating - this is a bit random, but that noise is loud enough...
  10. R

    Vented indirect cylinder venting issue

    A customer of mine lives in an old cottage that has been extended. They have three loft areas that are completely separated. The CWSC is in one higher loft space, the hot water cylinder and shower pump live in another lower loft. They are on different sides of the building. There is single 22mm...
  11. N

    Thermal Store cylinder

    So...got called to this earlier on, the install looks a bitnof a mess but looking past that the system seems like quite a simple setup though i am failing to find a schematic for this particular type of thermal store where we have 4 immersers which all on would be producing 12kw and an open...
  12. S

    Insulate a Unvented Cylinder

    Hi I have a warmflow unvented water cylinder (indirect 250) in a hotpress. It was installed two years ago, but never had any lagging put around it. Wanted to ask if that would have been for a reason why it wouldn't have, and also would insulation be a good idea to warp around the tank? Thanks
  13. I

    Draining ACV unvented Cylinder

    Hi Guys, has anyone come across the ACV cylinders, my client has SLE-160 in the loft and there is no drain off boss.. The cold inlet is on the top next to the hot outlet. I need to replace the immersion element located at the bottom of the tank. MI is not helpful. Possibly looking at...
  14. E

    HW cylinder leaking or condensation?

    Hi. I’ve just changed out a backup immersion heater on a copper vented cylinder. I’ve leak tested around all the connections to the cylinder using blue paper towel which tends to stain orange with moisture. After 24-48hrs of use not a trace of moisture. However after a week or two I’ve...
  15. S

    Can remove limescale from unvented direct cylinder (center store)

    I have an unvented direct cylinder from centerstore to use it only for hot water CenterStore direct unvented cylinder 120ltr | Wolseley - https://www.wolseley.co.uk/product/centerstore-direct-unvented-cylinder-120-ltr/ but with two immersion heaters. I had it the cylinder working fine for 4-5...
  16. M

    Primatic Cylinder help needed

    Hello everyone Before I succumb to this problem I’m reaching out for some help. There’s very little info on the web and I can’t get hold of a manual. The system is ancient but we’re not ready to renovate to a greener option for another 12 months so hoping to keep it going. Moved in with the...
  17. Jock Spanners

    Can I heat a vented cylinder with an empty coil?

    Evening All, I've dug myself into a hole due to being too busy and there being shortages of kit. Basically the Megaflow unvented cylinder I ordered last year has been delayed for three weeks and I cracked on changing the boiler thinking I could at least instal the boiler. So I'd put in a...
  18. J

    advice on timer control for Unvented Cylinder

    Would need some advice if I could replace Newlec Economy to OP Ecosave Timer control for “Unvented Cylinder Megaflo Water heater” As the current Newlec Economy timer control limits to heat up full tank of water during midnight only( one time a day. ) OP Ecosave Timer control allows to set...
  19. D

    Electric boiler and an unvented indirect hot water cylinder

    Hi, I have recently purchased a cottage with an LPG combi boiler (no mains gas in the area). I intend to replace this with an electric boiler and an unvented indirect hot water cylinder. The boiler will run four radiators and the hot water cylinder. The cottage has one bedroom. What size (kw)...
  20. J

    Rapid Recovery Cylinder Coils

    Is there a standard for the above?, ie primary flow rate, primary flow temperature, reheat time from X degC to Y degC, continuous flow rates at different temperatures and coil area. It would be very useful if, at the very least it specified the design primary flowrate and temperature, and the...