filling | Page 9

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

filling

  1. C

    Slow filling cistern - Armitage Shank

    The cistern is filling very slowly, just a trickle. I have looked at various videos and read tips on how to clean the valve from debris but cannot take this one apart!
  2. M

    Swapping a filling loop

    If swapping a filling loop because the slotted bit on the cold feed is rounded off and is barley able to be turned. Is it ok just to swap the cold valve. As swapping the valve on the central heating return will mean draining down the system?
  3. D

    Loud vibrating noise when colder water tank is filling

    We recently had a repair done to a leak under our kitchen sink. Since then we are occasionally getting a loud vibrating noise, which seems to happen when the cold water tank is filling up in the loft. Last night the noise went on for a couple of minutes. I'm guessing it's to do with the cold...
  4. brum

    system not filling

    alright boys working on this hotel header tank filling with water ok but just running through and not filling to level basically telling me theres a leak cos system not filling have lifted flooring on ground floor but not traced leak must be a big leak only sections of flooring not lifted are...
  5. D

    Immersion Heater Problem, Not Filling Up As It Should

    Hi, I was wondering anyone could help me. I am having issues with my hot water system, my immersion heater does not seem to be filling up very quickly, literally just sounds like drips. This has been the case ever since I changed my main water stopcock downstairs, unsure if this is related...
  6. C

    Over-pressurising with filling loop disconected?

    This one is driving me mad. Water was dripping outside through the discharge pipe, so checked the boiler pressure guage and it was indicating 3.5 bar! Initially suspected the Pressure Reducing Valve. It was looking wet also. Pulled the cartridge out and it was in a bad shape internally. Fitted...
  7. J

    Filling solar pipe work

    Could a power flusher for central heating be used for filling solar pipe - work??
  8. P

    filling loop

    hi all is there a preference for filling loop to the flow or return or no difference ta
  9. C

    G/Worm 30Ci filling loop is different to existing. Will it fit?

    I have been to fit a new dis-connector to a 30ci part number 2000802600. it doesn't look anything like the existing filling loop. The original dis-connector was 2000801908 but is now obsolete. Has anyone fitted the new loop to one of these boilers. Thanks for any advice. casaco
  10. B

    Ideal Locgic Combi 30 - Leaking Filling Loop (whilst trying to repressurise)

    Hello - i am trying to repressurise the boiler as its now at zero pressure. When connecting the filling loop (which is quite short and has a braided pipe), I then turn the filling loop isolation valves to the open position, and water leaks from both taps (blue and black). There is no...
  11. C

    help my system isn't filling up

    hi, i've just carried out some minor work to my heating system and it wont fill up now . i don't understand it usually fills up well, yesterday and today i have been removing rads and cleaning them by hand . last night i accidentally ran the system but i forgot to open the filter so the pump ran...
  12. A

    Halstead Ace - Repressurising Problem - No Filling Sounds Whatsoever

    Hi, I have a Halstead Ace boiler and just a few days ago, I went to repressurise it as the pressure dial was on zero and we had not hot water or heating. Anyway, when I used to repressurise before, I would hear the water going through and I was hear the pressure up. Now, I don't even get any...
  13. L

    Filling system up wrong.

    Hi all, when you fill a system its to my little knowledge, that you start downstairs rads first. So is it best to close one side of each rad seperately, anyside if you don,t no which is the flow and return? Then bleed the rad and then open the chosen valve, then move to the next one and do the...
  14. M

    Previous Plumber left filling loop opened

    Hello AllI manage 6 apartments in the same building and recent repairs to the plumbing and boilers and subsequent replacement of a boiler I noticed that these were becoming a lot more frequent and Following my inspection of the apartments I seen that the filling loop was still connected to...
  15. B

    Vokera Compact Se constantly filling

    Hi all, called to look at a Vokera compact Se (2005)where there was water constantly filling from the domestic hot water over pressurising the boiler. Checked expansion vessel and ok. I can't see any divertor valve, so am I right in thinking that there is a leak in the heat exchanger between the...
  16. D

    Auto flush infrared cistermiser with solenoid valve constantly filling.

    Hi all, I'm new to the forums and relatively new to plumbing, and wondered if any of you experienced chaps could help me out... I went to a job today, where they had urinals that were constantly running out of the flush pipe and wasting water. The cistern fill pipe was fitted with an...
  17. K

    no filling loop

    Hi everyone Im draining down an unvented stystem on the first floor, but I can't see the filling loop anywhere, or where one would attach. Surely it needs to be pressurised to 1.4bar, but how???
  18. Deleted member 32524

    filling old flue hole

    Hi all. Thanks for looking. I have 2 questions 1 how to fill old flue hole that does not conform to regs. Problem is its 3 floors up. Can't be reached from window. How to fill from inside!!?? If even poss. 2 gas line has to go past electric maim isolation switch before consumer unit. Only...
  19. C

    softened water and filling a cast iron boiler with modern unvented

    is it ok or even a good idea to use softened water in a central heating system? this is partially related to another post. the heat exchanger is iron, but it feeds via an indirect coil an RM stelflow unvented. will using softened water cause corrosion?
  20. H

    Slow, dripping water filling water tank in loft... Please see below:

    Hi Guys, I'm experiencing a bit of an issue here: When turning the taps on for hot water, there isn't any current / flow of water coming in and I don't know why. It felt as if something / someone turned the tap off. As a result, this has effected the kitchen, washing machine, dish washer...

We recommend City Plumbing Supplies, BES, and Plumbing Superstore for all plumbing supplies.

Back
Top