fittings | Page 2

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

fittings

  1. K

    PTFE tape or liquid / paste for compression fittings?

    Hi all I often find using ptfe tape with compression joints quite fiddly for my old hands, particularly in tight spaces. I was wondering if the ptfe liquid paste is a viable alternative? Does anyone on here prefer it? Thanks.
  2. J

    Re-usuable or not? Pushfit fittings

    I want to replace two of the flexible hoses that feed the shower mixer valve. I don't like how they have been bent at a right angle. All the fitting in our bathroom are these pushfit fittings. I don't know the brand. Fortunately, I have removed some sections of pipework in the bathroom and kept...
  3. System64

    Questions about types of pipe fittings

    Hi, I'm doing an automatic irrigation project with Arduino, which is connected to a solenoid valve which has male 3/4'' threading for water input and output (this solenoid valve - product page in Italian, sorry). I need to connect the output to a 16mm polyethylene pipe, and searching online I...
  4. J

    Compression fittings

    I need to replace the flow and return in the loft but using a torch is out of the question, is it wrong to do it entirely in compression? As don’t really like pushfit and press fit the cost doesn’t work out ?
  5. K

    Is replacement boiler all compression fittings above boiler normal?

    Hi opinions please replacement boiler same location as old, descending water pipes adapted to fit with 3 compression fitting each so each has 2 90 bends, short horizontal pipes and a coupler. overall 6 fittings with 12 olives and 4 bends all above new boiler, previously straight unjointed...
  6. M

    4” osma fittings advice please?

    I’m doing some 4” soil and I’m having a debate about what can be done with these fittings. They’re both 45s. The double socket has a ring seal on it facing up and the spigot of the other 45 goes into it the bottom. The 2nd 45 is then glued on the spigot and socket. Is this acceptable?
  7. J

    Concealed valve fittings

    Hi guys I'm just fitting a new concealed shower valve in my home. My question is I bought 2 22x15 adapting couplers and 2 15x15 adapting couplers, even with 15 wraps of PTFE I have a feeling the thread isn't going in far enough, I can literally tighten it all the way by hand , Is their any...
  8. A

    What fittings are these?

    I'm in the process of converting my garage. I've been looking for the existing radiator feeds. I came across these. Are they reducers? Don't know why they would be insulated?
  9. B

    Different fittings and length on Kitchen sink waste strainer

    Had to replace my kitchen sink waste strainer and have struggled to find a direct replacement. The old fitting is plastic with a screw on top to tighten to the sink. The length is 60mm with a 45mm thread diameter which screws into existing pipework. I shopped around and managed to source a new...
  10. J

    Best deals on 12mm mlcp pipe and fittings.

    Evening all, Can someone let me know of any good deals on 12mm mlcp pipe and fittings. Thanks in advance. Regards Jim
  11. G

    1" GHT thread (Female) to 1" NPT (Male) fittings needed Help!

    1" GHT to 1" NPT needed. I need to find a plastic or PVC type fitting to jin together two pipes. The female is GHT, and the males side is NPT. I need to buy a bunch of them on an ongoing basis. Can anyone help me find them. No mass or metallic as they are cost prohibitive. Thanks!
  12. B

    Fittings for drinking water

    Hi Have a little job under kitchen sink and need to know how to identify fittings (valve, tee, coupler) suitable for drinking water. Should I be looking for only EN-1254-1 or EN 1254-2 or something else? For example, is this one good for drinking water...
  13. R

    M-Press fittings experience

    Looking at replacing a stainless steel welded 90 metre water system in press fit. Its going to cost about £18k in Mapress but I have seen M-Press are alot cheaper on their fittings. Has anyone got any experience with M-press 89mm fittings. Just wondering if they are cheap for a reason.
  14. A

    Grey Hep2O Fittings Unscrewing!

    I've searched this forum but cannot see anyone else reporting a similar problem with the last generation grey Hep2O fittings: they unscrew! Our whole house was re-plumbed in 1999/2000 and Hep2O fittings were used throughout for all out-of-sight fittings - just over 200 of them. One evening...
  15. S

    Where to obtain Marley plumbing fittings

    I've recently cleared a fatberg from the drain pipe underfloor and am now in the process of fitting everything back together. The cropped out pipework is easy enough; a couple of Flexseal PF56 couplings which are just the right size for the 56mm OD pipe. The boiler condensate drain I will...
  16. J

    Plastic push fittings on oil boiler?

    Was at a house today and their new oil boiler was installed in a pretty shoddy fashion. Aka Plastic tiger loop screwed to the boiler casing. And the main thing was really untidy pipework. Thrown together with a pile of grey plastic push fittings and copper / plastic pipe mix. For example...
  17. Riley

    MLCP fittings for sale

    Guys been having a thorough clear out and have a stack of Wavin and Multipipe fittings as well as decent amounts of Multipipe 16mm, 20mm and 25mm pipe. Will be putting them on ebay later with the caveat of selling them elsewhere. If anyone wants to take a look and make me an offer I’d rather...
  18. plumb_know

    crimp & Press fittings

    I have taken the plunge and invested in crimp system for a new build house we are doing, seems ok but i now need to get copper fittings and wondered if anyone know where best to get them for a good price??? Would like to use this a lot more, but need to get fitting prices down
  19. D

    Shower riser bar leaking & unable to remove fittings.

    We have located a leak from a shower enclosure...culprit is the riser bar, as soon as water is hitting the bar it's coming through into our kitchen ceiling. Having difficulty getting the fittings off the wall too to investigate .
  20. B

    Hep2o fittings failing

    I see there are various previous threads on this and other sites which discuss Hep2o fittings, I use these fittings and have not had any issues with any that I have fitted, however I have become aware of a few recently which have failed, I know of a block of 45 flats ( 7 years old) where each...
Back