  1. hatchwork

    60mm flue inner in Glasgow!

    Hi All, This is a bit of a random one, but I'm a product designer working on a lighting project and I'm on the hunt for unused/waste/offcuts of the 60mm plastic flue inner that you get with some boilers. If anyone in the Glasgow area has any of the white for translucent stuff, I would...
  2. R

    New flue letting water in through middle.

    Just had a massive downpour and seems the inner tube of the vertical flue lets water in . The boiler is not connected as the plumber is doing that next week but I have put the flue through the roof hence noticing it . It's a condensing flue for oil system. It is new and water is only coming...
  3. CorgiDirect

    Get a FREE Service in 2022 with Testo Flue Gas Analysers 300, 327 or 320B. Save over £100

    Testo FREE Service Promotion. Buy a Testo flue gas analyser 300, 327 or 320B kit before 31st December and get a FREE 1st year service in 2022. Save over £100. Don't forget to register your analyser. More information here - https://corgi-direct.com/testo-flue-gas-analysers-18088-0000
  4. IanHoll

    Vertical Flue Install

    I've just had a Worcestershire Bosch installed by a gas engineer and heard him talking about having forgotten elbows, was it 90 elbows that he forgot and should have installed? The hole made in my ceiling is horrendous due to the 45 degree entry, but the plate he installed cover the mess. Can...
  5. CorgiDirect

    Up to 21% Off Testo 300 Flue Gas Analyser Range

    Up to 21% Off Testo 300 Flue Gas Analyser Range Offer Valid until 31/08/21 Excellent Special Offer on Testo 300 Flue Gas Analyser Range 😲 - https://campaign.emailblaster.cloud/MTU4NDA/24.html
  6. R

    Condensate dripping from boiler flue - advice please

    I have an Alpha Intec boiler installed on my loft wall. The flue goes horizontally from the top of the boiler and passes through the wall, exiting high up in the gable end. The boiler was installed about 6 years ago. My attached garage joins the gable wall directly below the flue. I had the...
  7. S

    Help with Convesa Black Twin Wall flue

    Hi Could anyone help or advise me please? I have a Black 5'' Convesa Twin Wall Flue from my dining room to outside wall, the flue needs another 1000 mm pipe fitting as the cowl is to close to the ridge on my dormer window, the flue was fitted in June 2016, the current Convessa flue is KC which I...
  8. R

    Is this ridiculous (boiler serviced and flame adjusted with flue buried in snow)?

    The boiler downstairs was serviced (not to be confused with the one with the gas leak - this is a separate boiler). The chap said the flame was not burning that well and so he readjusted it. All seemed well. Today I looked up at the house. Given that the downstairs boiler is never used...
  9. S

    Leaking Flue pipe from Boiler

    Hi all, Had a plumber come round today to service our boiler and it turns out he's had to turn it off as unsafe due to some water leaking on the outside of the flue pipe. At the time the plumber said that the instillation was done terribly and that if I really wanted I could report the job as...
  10. K

    Combi boiler with low flue???

    Hi all, I hope someone will be able to advise. I have recently purchased a flat with a faulty Potterton Netaheat Profile system boiler. The system is pressurised and I would like to replace it with an efficient Combi. The current boiler is situated close to the floor and the current flue is at...
  11. R

    High pitch noise from boiler flue

    Hi, My boiler has started making a very high pitch noise when the heating turns on. It seems to be originating from the boiler flue (see video https://bit.ly/3pYMFrI ) Is this an indication of air trapped in the system ? Do radiators need bleeding ? Or a sign of faulty boiler part ? Thanks
  12. M

    Boiler Flue

    Hi Guys My Baxi Duo Tec Boiler as developed a condensate leak where the flue pipe connects into the flue elbow. I suspect the seal as gone in the elbow and so I want to replace it. Having looked on top of the boiler casing, where the elbow connects to the boiler adaptor there are two, for...
  13. B

    Boiler Flue

    Hi. Could you tell me if a flue that exits a wall horizontally for approximately 8cm and then goes upright at 45 deg for another 8cm is legal? I was wondering if the flue could get blocked or let in a lot of rainwater. Thanks.
  14. D

    Flue location concern

    Hi looking for some advice. I need to get a new boiler fitted in the next few months and I’m concerned about the flue location above my conservatory (ignore the mess which is due to be cleaned away). Can anyone give me there opinion on this? If it’s a problem, can it be resolved in its current...
  15. CorgiDirect

    If you're thinking of upgrading your flue gas analyser, we've got some great news for you

    If you're thinking of upgrading your flue gas analyser, we've got some great news for you. New testo 300 domestic models (limited edition black handset) have price offers, and get a free testo 830 IR thermometer with testo 327 and 320B kits -...
  16. J

    Boiler Flue Regulations

    Does a window need to be atleast 30cm away from the base of the boiler flu (the part that comes out of the wall/opening) or the end of the flue where the fumes actually come out. Our window opening is less than 30cm from the hole where the flue comes out, but the end of the flue is more than...
  17. J

    rain water coming into Ideal Combi boiler through flue and causing main circuit board to blow.

    The main circuit board has gone 3 times in the last 3 months after heavy rain. I have a maintenance contract with British Gas but they will not keep replacing the board FOC. How can I stop his happening? The boiler is 7 years old and I have not had this problem until recently so what will have...
  18. J

    Renewing flue

    I’ve to renew a Flue on a Vokera Unica HE today. Nothing wrong with it, there’s a new window going in and the flue needs moved along a bit. Maybe just a case of Fitting a 45 to the bend to take it out a bit. Anyway, I’ve never done this before, I never do maintenance work, only installs. Would...
  19. J

    Drain off valve *this* close to boiler flue

    Hope you're well. After finding a leak on our CH drain off valve (that our servicer missed)... have realised it's very close to the boiler flue, like impossible to use and right up against it. It's on the return CH and hidden behind the flue. What do people think? I'm going to drain down and...
  20. J

    Flue too close to window above flue

    Hello! Hope you're all well. I've read guidance and searched the forums before posting this..... Had our boiler serviced and had a risk notice put on it due to the flue being too close to an openable window. A flue installation fault was also found (sloping down wrong angle for condensing to...