flue | Page 6

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

flue

  1. L

    Efficiency of old boiler and cracked asbestos flue joint

    Hello, I live in a conversion with 12 flats and we have communal heating and hot water. We have separate boilers for heating and hot water. The boiler for heating is a Potterton Dimplomat 225 (66Kw), and about 45 years old or more. If you were to take an educated guess, what kind of...
  2. F

    Boiler flue and conservatory help

    We currently have a Potterton suprima 40litres.boiler the flue comes out where the conservatory we are planning to build will be. Can anyone advise what our options are please other than moving the boiler. Thank you.
  3. D

    NEW STYLE OF FLUE TERMINATION

    Hi Everyone, Just thought I'd post a picture showing a whole new approach of terminating a fanned flue. Installed by a loft conversion specialist!!!(more likely a family friend.) Unbelievable!!!
  4. centralheatking

    Fan Flue Boiler with good internal fitting arrangements

    On behalf of a friend we are looking for which fan flued ng combi or system boiler has a good fitting from inside only. The outside is in Bath and 3/4 Floors up but the outside is above the River Avon so no ladders too high and no scaffold...unless expensive suspended stuff. around 20kw to 30kw...
  5. O

    Flue distance from facias

    Hi can i get some advice, does the facia and soffit of the house class a eave, as the flue coming out of the wall is more then 200mm from the eave but only 20mm away from soffit and facia. Would it still need to be a distance of 200mm or would it be 75mm same as guttering and drain pipes...
  6. king of pipes

    Valliant pure rear flue

    Anyone fitted these problem I am finding is it does not close down enough for the thickness of the wall and cannot be cut they are not the same as a normal horizontal flue , phoned Valliant technical they said it is what it is not alot of help. Kop
  7. M

    condensing flue through cellar roof to above-ground ?

    Hi all, can anyone advise if it's possible to route a flue from a condensing boiler in an underground room up through the ceiling (15" thick) where it will come out above ground on a flat surface ? And from there it will extend up the side of the house, as in this picture ?
  8. F

    Rain Leaking Through Flue & Onto Boiler

    Hi all, Bit of a weird issue with my flue. I live in a 1st floor flat and over the last 12 months or so more & more rain water has been leaking through my flue and on to my boiler. The leaking only happens when the rain is driving directly towards the flue. When the rain does drop back...
  9. Z

    Which combi boilers are available with a rear flue option?

    I'm after a boiler with a rear flue option for a replacement cupboard installation, i know the Vaillant Ecofit Pure and Gloworm equivalent but i've fitted one before and wasn't really happy paying a grand for what seems to be essentially the same as a £480 Heatline Capriz2 so was looking for...
  10. king of pipes

    Tenerife flue !!!!

    Sorry chaps couldn't resist this one obviously no scaffolding or grinders here 😁 😁 kop
  11. CorgiDirect

    Free Testo 830-T2 Infrared Thermometer worth £50 with every testo 327 or testo 320 Flue Gas Analyser Kit

    VIEW HERE Free Testo 830-T2 Infrared Thermometer worth £50 with every testo 327 or testo 320 Flue Gas Analyser Kit
  12. CorgiDirect

    Buy a Testo 300 Smart Flue Gas Analyser Kit and receive a FREE Wiha speedE E-screwdriver worth £200

    Buy a Testo 300 Smart Flue Gas Analyser Kit and receive a FREE Wiha speedE E-screwdriver worth £200 VIEW OFFER
  13. A

    Vaillant ecomax flue corrosion?

    Hi guys, looking at a vaillant and the flue shows signs of corrosion on the air intake, I put my analyser in and o2 was coming back at 20.9% with no co readings so flue integrity is fine. It must be caused by water ingress from rain but wondering if I should at risk it or not.
  14. J

    Flue termination distance

    I’m going to be moving a Vokera Unica i32 on Monday. I had a quick look at the building while driving past and it looks like the steel gas service pipe running externally to the flat above is where the flue would come out so I’ll have to re direct it a bit. I was looking at BS 5440 and can’t...
  15. Scott_D

    Flue integrity test

    I always do a flue integrity check on the air inlet sample point. Never had an issue. Doing one today and I realised I don’t know what values the are to be classed as a fail. Can’t seem to find it in my books either. Is there a TB I can read to refresh my brain?
  16. B

    Rain water coming in through flue.

    Hi I had this problem earlier in the year (I’ve got breakdown cover with British Gas) they came out and diagnosed the problem and fixed the boiler but the engineer told me that the breakdown cover doesn’t cover the flue and if I had the problem again it would be very likely they wouldn’t come...
  17. M

    Vertical flue through 4 pitched roof

    How do you go about putting a vertical flue up through a roof where you cant get a roof ladder to hook over anything. They have a vertical flue in now and it's on a pitched roof but a side one if you get what I mean. I'm guessing scaffold up then unsure what to do next.
  18. S

    Metallic clanking from boiler flue when boiler is off

    I've got a boiler installed in the bedroom. When it's windy/rainy outside and the boiler's off there's a metallic clanking/tapping sound that seems to be coming from inside the flue. I've posted a video here (). You can only just hear it in the video, but it's fairly loud and is waking me up...
  19. O

    Best flue gas analyser?

    Just starting out.. giving the self employed world a crack. Anyone recommend a decent analyser? Used a anton sprint with my last employer which seemed decent enough. Was looking at the Kane 255 .. Seems reasonably priced compared to the rest!! Are they any good though? Already got a seperate...
  20. A

    How can we block off an unused external boiler flue?

    We had a boiler in an old shed adjacent to the house. The flue is encased in a brick chimney stack that runs up the outside of the house. Some years ago, the boiler was moved inside, but the old flue remains. It looks like a chimney but is open at the bottom and unsightly. I am not sure...
Back