flue | Page 9

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

flue

  1. finchy01

    Balanced flue gas fire

    Morning all, a new customer has approached me asking for a balanced flue fire as there current fireplace has had the chimney removed. The only problem is there is a garage the other side of the wall. I've installed a few like for like fires but never a Balenced for our fan flue one. Do you know...
  2. I

    Flue marked as Dangerous?

    Hi, I've just had my combi boiler marked as at risk / possibly dangerous due to some small "Thumbnail size" corrosion / oxidation of the end of the flue pipe, which I guess is due to years of condensation sitting at the end of the pipe. I appreciate that a damaged flue could let exhaust...
  3. Z

    Kane 255 Flue Analyser

    Hello, i had my van nicked (along with all my tools) the other week so have had to replace everything and need a new analyser. I had the Kane 458 before with all the bits and was happy with it but the 255 is so much cheaper and i'm wondering if i really need the better one. As far as i can see...
  4. J

    Oil boiler flue needing a hat

    Hi all, Please advise or send link to a suitable terminal/rain-cap for this oil boiler flue.... MTIA.
  5. J

    Boulter oil boiler flue terminal

    Hi all, Should this Boulter Camray oil boiler chimney/flue have a 'rain-cap' on? If yes what type please.
  6. G

    Vaillant flue parts job lot. (all unused and wont be split)

    Due to imminent retirement plans, Im having a clean out; 2x vertical flues 0020223472, 15x 1Mtr straight lengths 303903, 10x telescopic lengths 303906, 3x Vaillant condensate pumps, 4x incomplete Vaillant condensate pumps, 5x stand off brackets 308650, 25x boxes flue brackets 303935, 35x 45...
  7. L

    flue terminal too close to cooker vent

    some advice needed, I could do with some input on a fanned flue outlet being 200 mm away from a cooker hood vent, the vent has flaps which close when not under positive pressure from hood. would this be classed as safe due to the flaps closing when cooker hood not in operation. I respect the...
  8. L

    fanned flue terminal

    bit of guidance needed. I have a flue which is round about 200 mm away from a cooker hood vent, the vent terminal from the cooker hood has got flaps which are closed when the cooker hood is not in use, so effectively only open when under positive pressure from hood, just a bit unsure as to what...
  9. O

    Can you seal a flue with expanding foam?

    Getting mixed answers about this. As far as i know expanding foam around a flue is an AR. Does any body have a concrete answer?
  10. Riley

    Flue in a carport....

    I have a problematic boiler where customer has let slip that he intends to build a carport around the flue terminal. He has already had a plume kit fitted thinking this would be sufficient if the periscope comes out through the roof of the car port. He has now told me that he intends to put...
  11. L

    Twin flue boilers to replace Keston

    Hi there, Quick question to you all please. (I am Gas Safe registered incase anyone is wondering) I need to replace a Keston (suprise suprise) and really need a boiler with a twin flue similar to that of Keston. The client under my guidance has agreed that she does not want another Keston. I...
  12. Scott_D

    Vert flue from a chimney stack

    I know I would need to check with MI's for boiler specific info - But can anyone tell me the standard measurement for a vert flue from a chimney stack? Is it 1500mm?
  13. T

    Advice please on flue

    Hello I am after some advice if possible. We moved into your new build home in June 2017. We had our first annual boiler check about 4 weeks ago and 2 things were found 1: gas leak which was traced to a squashed seal on the hob. It was suspected it has been like that since we moved in and...
  14. M

    Flue liners install

    I am currently quoting for a job installing a 160kw boiler which will require a flue line for the flue. Do you guys have any recommendations of companies who fit these, the job is in north London.
  15. S

    Old hot air heating flue

    Hi I was wondering if you could provide me with help/your advice regarding an issue I have with a redundant flue from a old hot air heating system (was removed years a go). I was in the loft and noticed the flue collapsed from the wall to the vent in the lofts roof. It looks like it snapped...
  16. T

    Biasi Garda m90f 24s flue

    hi need to replace a flue on a biasi M90f 24s boiler. Does anyone know which flue fits? Thanks
  17. B

    Rain ingress through boiler flue

    Hi Guys I have an Ideal Logic System s24 which was installed approx 2 years, and haven't had any problems with it. This morning there was a wet patch below the boiler, and multiple drops of water under the boiling casing. I turned offbthe power and popped the cover off just to look, and it is...
  18. M

    Combi boiler flue through soild external wall

    Despite BG covering my boiler with Homecare for years, they have just decided that the external flue is now not sufficient - quoting new Regulations - and they won't cover my boiler any more! The flue has a large square opening (as shown) and is around 200mm deep. Can anyone recommend how to...
  19. M

    Condensing Boiler Flue Discharge

    I have recently had a Worcester Bosch 30Si boiler installed and it works a treat. However I have noticed that when it is fired up, in addition to the plume there is a steady drip of water that comes from the flue (externally not internally). Is this normal because I thought all the condensed...
  20. S

    boiler that accepts horizontal flue

    hello have a keston boiler.. touch wood .. working ok .. but time soon to replace .. we originally got a keston because there is a horizontal flue over about 5 meters .. which other brands of boilers would be able to be slotted in to replace the keston when needed ? thanks