glow | Page 8

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

glow

  1. F

    Glow Worm Ultra come 30cxi ... various pressure issue

    I had a glow worm ultra come 30cxi fitted 3 years ago by calor gas and it runs from a outside gas tank. The last 6 months I have had pressure issues with it. When set at 1 to 1.2 bar when the heating comes on it can reach upto 3.4 bar, but when the heating switches off it can drop all the way...
  2. R

    glow worm 18hxi F1 fault help

    Hi I have a glow worm 18 hxi keep getting F1 fault some times it will run and work fine. The next time it will go to start up the green light comes on for 3 secs and click click click light goes out and F1 red light flashes. you can turn it on and off 10 times then it will run fine. until the...
  3. J

    LPG Install - Glow Worm Ultracom2

    So help needed please... Just got back from a landlords certificate, LPG bottle system with a Ultracom2 30cxi installed, gone to do FGA hook up analyser put boiler into P1 mode boiler fires then FGA readings go off the chart and analyser alarm goes off, pulled analyser out as i did the co2...
  4. C

    Glow Worm Flexicom lose water pressure and more...cost?

    I have Glow Worm Flexicom which seems to have a few issues. It keeps losing water pressure over few weeks, and until a few days ago was making a loud bang noise when switching hot water/ central heating. I have one of those water tank systems. I called a gas engineer who has a quick look and...
  5. P

    Glow worm betacom 28

    We'll I started fitting my first glow worm betacom 28 Combi today, Not everything went acording to plan brought my core drill and core cutters but no 110 transformer so had to give my SDs a good working But got it on the wall and started laying my pipe work out and prepping for tomorrow...
  6. T

    Glow worm betacom 30c humming sound

    I got a betacom 30c in my own house and this week it's started humming/whiring sound when hot water is drawn off, this sound is intermittent. The temperature is fluctuating also. We done the install about 5 years ago and maintained with inhibitor f1 yearly. My mate done the boiler as I am not gs...
  7. C

    Glow worm 30cxi F13 fault

    Hi all, had a customer on the phone with an F13 fault on a Glow worm 30cxi fault which is the PCB connection fault. Has anyone else come accross this? Thanks
  8. K

    New glow worm gas boiler

    Hi just had my old baxi back boiler replaced for a glow worm energy 18s system boiler which seems to be working well. However I have noticed the burner is always burning when it is on via the timer. Is this normal for a condensing boiler as I have not had one before.
  9. M

    Glow worm flexicom 30cx?

    Hi guys. Do the front cases on these boilers have like polystyrene inside of them? If so what's the purpose and what if it hasn't. ?
  10. A

    Glow worm space saver MKII problem

    Hi I have a glow worm space saver MKII boiler. It wasn't firing up and thought it was the main boiler thermostat & thermocouple, I purchased a new Ranco CL6P0102 boiler thermostat c/w thermocouple fitted it and the boiler fired up. This worked for a couple of days then the same thing happened...
  11. moonlight

    Glow worm flexicom 24cx

    Just a quick question. Can any one tell me if you can centralise the diverter valve through the installer section or does this boiler not have the option. I usually work on Valliant boilers, which do have the option. Makes for draining boiler and repairing far eaiser. Thanks
  12. RoryD

    Glow worm Micron 50FF

    I have a customer who is really having some bad luck with his boiler. Over the past 2 years I've replaced 2 PCBs and a Gas Valve. There were other issues but not regarding the boiler itself. Tonight I have received a call about the boiler cycling on and then going off but both lights are...
  13. N

    Gas valve for old Glow Worm boiler

    Hi, I need to choose a replacement gas valve for a Glow Worm Spacesaver 38 (MkI) boiler (please don't laugh!). Any suggestions? Thanks. Nick
  14. D

    Glow worm 25cxi

    Hi all, Just wanted to get some advice... I live in a 2 bed bungalow which has a glow worm 25cxi combi running the hot water and heating system, I've lived in the property about 2 years but the boiler is about 9 years old. It it was about this time last year i had problems with the hot water...
  15. S

    Glow worm flexicom 18hx how to fill water + no pressure gauge??!

    Hi, hopefully somebody can help me with this. The boiler in our house is a glow worm flexicom 18hx but it doesn't seem to be heating the downstairs radiators even though they've all been bled. I'm putting this down to lack of pressure and that fault code comes up on the boiler if I turn the...
  16. G

    Glow worm betacom 24C low pressure

    Hi there, I have this problem which valve i need to turn what direction? Husband away, and no heating and hot water suddeenly on saturday evening.:mad: pleaase help, thank you
  17. P

    Glow Worm 23c Combi - Pressure Varying

    My son has a Glow Worm 23c Combi Boiler fitted in his flat, over the past couple of days the pressure has been playing up. Basically, about 5 minutes after the heating switched on the pressure dropped and the heating switched off. He refilled the system to increase the pressure and heating came...
  18. M

    One for the Glow Worm experts..

    I don't suppose the Betacom 30C has the same jig or pipe spacings as the lexicom 30cx by any chance?? It would make my day if they are the same... :)
  19. P

    Dual Glow Worm Flexicom SX Boilers - F9 Fault Code

    I have recently linked 2 no. Glow Worm Flexicom 30sx boilers and connected them via 35mm pipe work to a low loss header to serve an under-floor heating system in a large, new build, domestic property. The boilers have both been suffering with a reoccurring F9 fault code which is taking them out...
  20. M

    glow worm 30sxi low pressure

    hello I need a plumbing enginner in ld3 area Brecon south wales to change the pressure vessel and pressure relief valve if required. my e mail [email protected]