ideal | Page 7

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

ideal

  1. D

    Ideal Mexico with no F&E Tank?

    Hi, i've done a system conversion this weekend. Ideal Mexico out and vaillant ecotec combi in. Everything was stripped out but i couldn't find a F&E tank in the loft. Just a CWSS. I then looked for a filling loop and expansion vessel as i thought somebody may have converted it a few years back...
  2. T

    Wanted. Ideal Mexico super slimline CF 475

    Hi Everyone. I am looking for the 'Collector hood and Cleanout cover' for a Ideal Mexico super slimline CF 475. Or would a similar model number have the same hood and cover ? If anyone knows. Many thanks Tre Chen
  3. H

    Ideal Heat H18

    Hi All after some advice. Called out to a boiler with a noise(didn't do it when I first got there), reverberating noise on low rate. It was also due a service, checked and cleaned condensate( and pipe), cleaned heat exchanger,(replaced burner as deflection in the plate), replace spark/flame...
  4. king of pipes

    Ideal Logic 24 kw mk1

    6 th time I've serviced this boiler I fitted 7 years ago not missed a beat had to change the burner gasket and spark electrode gasket today other than that it's still all original and in good condition. 😬 Kop
  5. king of pipes

    Ideal Logic suprise

    Had a strange thing happen on a routine service yesterday chaps got it sorted. Kop
  6. C

    Ideal Evomax 80

    Hi, I hope someone can help with my boiler. I have an Ideal Evomax 80 fitted in my house (which does seem like overkill). I've been told that this actually a commercial boiler and therefore is always on so that heat is always available on demand. Is there any way to turn this always on...
  7. E

    Ideal Standard Dualux Bathroom Monobloc Taps

    Back in the 1980's we bought a few of the above which have ceramic disc cartridges. Generally been very reliable although have dripped which I think was caused by tiny pieces of grit scoring surfaces. Our water supply is from a reservoir and when the Water Authority did routine cleaning water...
  8. H

    water pressure and flow..what's the ideal combination

    Water pressure static is 8bar. Working pressure (if that's the term) is 6bar. Flow rate from cold water is 28-29L/min. Now this seems good (to me) but reading some suggested figures for ratings at different outlets, my readings seem almost dangerous by comparison. What should I be aiming for to...
  9. M

    Ideal boiler back clip

    I fitted a ideal boiler that had slight damage to the black clip that sits under the white clamps of the case to position on to. Its not effecting the case seal. But wonderd if there available separately thanks. Hope that makes sense.
  10. T

    Ideal vogue combi 40kw

    Hello, pressure dropping rapidly after being set to 1.5bar drops to 0 within a few minutes. I’ve been round all the radiators bled them checked for leaks (none found) and re-pressurised, dropping back to zero again. No water dripping from ceilings or around skirting boards, any suggestions, do...
  11. M

    Ideal Logic L3

    Hi lads any of use ever come as an L3 on a logic? Nothing at all in the book about it just all pointed towards board when I was there, swapped it inc code plug, swapped thermistor whilst I was there and all that's done is I can now run just hot water for about 15 mins ... before it was heating...
  12. M

    Ideal vogue c32

    Hi, just moved into a new house with the above boiler fitted about 3 months ago. getting to grips with setting up all the timings etc. One thing I have noticed is that on the display even with the ch off the ch radiator on the display flashes and says on. Am I missing something or is this a...
  13. C

    Ideal logic plus and halo room stat, check serial number first

    morning as told by my local ideal rep if the boiler has a serial number earlier that AFQ meaning it was manufactured on June 2019 or before you will be unable to use/bind the new Halo combi stat
  14. U

    Ideal Icos HE30 boiler start-up sequence

    My Ideal Icos HE30 boiler has been reliable starter since its installation 12 year's ago. It has been serviced every year since by the original installer. Today the boiler failed to fire though the thermostat is calling for heat. I replaced the batteries in the thermostat. I turned the...
  15. T

    Kettling ideal classicFF

    My boiler keeps kettling even though stat is right down, 2 plumbers have both flushed and chemically cleaned system. Could it be the pcb
  16. R

    Ideal logic combi 24 no hot water

    Gas engineer here. Been to an ideal logic combo 24, (the older model with brass manifolds either side) customer complained about temperamental hot water. Did the usual checks solid red light on hall sensor diverter head ok diaphragm springs back return thermistor above pump ok thought it must be...
  17. A

    ideal independent C30 boiler: Which pipe is which?

    Hello everybody. I've just bought a new house and the previous owners left me nothing of any help whatsoever. Thanks previous owners! Anyway I just wanted to understand the valves n pipes underneath my boiler I think I have discovered an external filling loop under the worksurface I have...
  18. R

    IDEAL LOGIC COMBI 30, hot water not very hot

    IDEAL LOGIC COMBI 30, hot water not very hot, water flow fine. Would I be right in that the diverter valve cartridge needs replacing. Any other suggestions
  19. B

    Choosing an ideal boiler

    Renovating an old rural cottage out in middle of SW England. Excellent gas fitter working for me. Property will be sold or rented at some point in the near future. Looking for a small modest combi. Gas fitters all have their favourites it seems maybe bad experiences with some or...
  20. fronty

    Ideal Logic combi cycling when CH hits 50

    Hi, my Mum's Ideal Logic combi keeps cycling when the temp reaches 50 degrees despite the CH control set to max. The manual says the flow temperature should reach 80 when set to max but I can actually hold the CH feed pipe with my hand and it never gets hot enough to cause me to let go before...