meter | Page 10

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

meter

  1. A

    A QUESTION? (Outside Meter box)

    Hi peeps.... Are there any meter fixers out there? With this wet weather, ☔ Looking for some sort of weatherproof canopy / makeshift ☔ ideas that I can get out of the van, pop out and stay dry and exchange meter without getting wet...... Any ideas/ suggestions? Cheers
  2. C

    Gas meter

    Morning guys, just a quick message, out where I'm working I noticed a small lever on the side of the gas meter with like a green handle on it, I've never seen one like that before and the guy was telling me the engineer that did his central heating system had problems with it, said unless he...
  3. Super Mario

    New water meter fitted now got loud noise from mains pipe?

    Makin loud intermittent noise since new meter fitted Does it need an expansion vessel?
  4. P

    Recessed meter box

    Went to look at a job last night where it is was a recessed box with the gas pipe going through the spigot but someone had teed in and then drilled through the back of the meter box. It was all sleeved and sealed but I presume it is A.R as the meter box has been compromised. Also do they do a...
  5. B

    Gas meter

    Got a large house that's got a 24kw boiler and hob on one floor and upstairs will be having its own boiler 24kw I am sure there is a formula on percentage of use on a gas meter. I am hoping meter will feed it all
  6. E

    gas meter cupboard

    hi all, I went to complete a job (in a flat) after vokera condemned a boiler as the flue wasnt sealed in the wall. This is now resolved. The place has had a cp12 issued for the last five years even with the hole in the wall. The kitchen is small (around 10m3) and has no openble window and a hob...
  7. P

    3 properties off 1 gas meter

    Please advise, we have one commercial gas meter serving 3 buildings each with its own secondary ECV and test point after the main ECV and meter, we are RGI but not commercial, can't access the other two properties but need to do work in the 3rd property, we've isolated our ECV and carried out a...
  8. P

    One gas meter to 3 properties

    Please advise, we have one commercial gas meter serving 3 buildings each with its own secondary ECV and test point after the main ECV and meter, we are RGI but not commercial, can't access the other two properties but need to do work in the 3rd property, we've isolated our ECV and carried out a...
  9. B

    12 meter header – 18.5 meter pump – Addition to system.

    We currently have an oil boiler producing 50/70 kw linked to a 25mm 5.5m head Grundfos circulation pump serving zone 1 as detailed below (pressurised system). The boiler is in the basement so there about 4 meters from the bottom of the boiler to the top of the radiator in Zone 1 office. Zone 1...
  10. R

    Gas meter information

    Hello all, Firstly, I apologise if this isn't posted in the correct section. I've been invited to an interview with SSE for a meter installer role. I am qualified in MET1, however, I have zero real experience working with meters. Its been well over a year since I passed, and I cannot find my...
  11. T

    Isar with a 5 meter flue run

    Chaps, i have an Isar to look at with a twin pipe 5m flue run which needs axing. Really badly designed apartments and going to be a nightmare to get a new flue in as the ceilings were put up after the boiler and flue went in. Walking away isn't an option and i'm thinking i'll have to wreck the...
  12. T

    Secondary meter

    Hi guys, I have a met1 ticket and was meant to fit a secondary meter for another gsr, he has now changed the schedule and I am away when it is due to be fitted. I have been told that any gsr can fit secondary meters without a met1. Can anyone clarify this for me? Thanks
  13. 1Steven

    Gas meter no supplier!

    Hello, working on a couple of flats with prepay cards. No cards and not listed with any suppliers! Any ideas where I go next.
  14. Scott_D

    Too much on a U6 meter

    Went to give a quote today on a house with 2 boilers The main house has a Vaillant 938 storage combi and the basement 'flat' has a 24kw combi There were 2 gas meters but when the owner bought the house, they knocked through to the basement flat and had one meter removed so not to pay charges for...
  15. J

    Gas meter

    Anybody come across a metrix G4 pulse meter?
  16. stani

    Smart meter. Or, not so smart meter

    Has anyone had a problem where the meter has shut down and then no gas released. My parents rang yesterday heating not working or gas fire, they are under contract, so engineer came out, thought is was governor, (sensible) asked for National Grid who came out but were unable to change meter...
  17. hammers4spanner

    card meter

    Had a landlord phone me saying tenant is complaining of cost of gas saying 40 quid a week and its only on hour or two a night. Gonna check for gas leaks etc first but also wandering as they are on card meter can these things go faulty ?
  18. Hobo128

    E6 gas meter

    At a job which is having major work done. I'm moving the boiler and the gas meter is being moved too. I need to remove the gas meter tonight and put it somewhere safe. With it being a e6 meter I'm wondering if there is a limit of time that it can be disconnected for or will it throw up any kind...
  19. T

    Leaking pressure relief valve by water meter.

    Hi all, I've got a dripping pressure relief valve on the very odd plumbing by my water meter - the setup looks like this: The cold water comes in from the mains through the large blue valve to the water meter, through the pressure gauge which reads about 3.5 bar then hits the 6 bar pressure...