  1. gingalig

    Meter spigot pipework badly sealed

    Hi, Sorry for posting the obvious to the more experienced of you, I've just come across a meter in a box with the gas pipe going out through the back via the spigot, The transporter had apparently come and changed the regulator a couple of weeks ago, my issue is that there is a lot of what looks...
  2. R

    Water Leak between meter and house?

    Hi All I have had a problem with a leaking toilet (and consequently a horrendous water bill!) but that is now fixed. But still the water meter turns - very slowly - the last of 4 red digits increments once per minute. So I presume that is 1/1000 m3 per minute? (or 1.4m3 per day!) That is still...
  3. B

    BK-G4 gas meter advice

    HI, sorry if ive posted this in the wrong part of the forum but im after some information on BK-G4 gas meters. Mainly do they make an imperial one? Ive has a smart meter fitted and my bills have dropped by an absoloutley shocking amount. I've been looking through my old bills and it says i...
  4. J

    Water meter - Moving

    Currently I am in the process of moving a water meter, within the same room (with the water company's ) agreement. After which they will inspect it and seal it. The nuts attaching the compression fittings to either side of the water meter have a couple of holes around the nut besels so that...
  5. D

    Gas safe for smart meter trainee engineer

    Hello all, looking for a new job and trainee smart meter fitter in a fourteen week course turned up. The course involves a mix of classroom and field instruction and lasts fourteen weeks, the recruiter states the course is part self funded and the rest by an employer. Is fourteen weeks enough to...
  6. J

    Water meter not measuring upstairs usage

    Hi all, I've moved home recently and was curious to see how much change in the water meter reading having a bath would have - The meter is in the downstairs toilet so I can see the reading. I've noticed however that after a bath, there was no change at all in the reading, if I run any taps...
  7. K

    Is ventilation required for a meter cupboard ?

    Is ventilation required for a gas meter cupboard ?
  8. moonlight

    How do you gas rate an appliance with a new smart meter?

    I haven't had to do one as yet. Two LGSC recently and they had new meters, just would like to know before I have too. Thanks.
  9. townfanjon

    Meter to close to fusebox

    Gents , on a job at the moment meter is around 100 mm away from fuse box , obviously not ok , whats the crack as regards some seperation either plastic or timber. Cheers in advance
  10. Inverness

    Gas rate on a flonidan G4 gas meter

    upcoming meters how do we do a gas rate on them?
  11. townfanjon

    Oh no , the smart meter installers strike

    I know a load of my pals have had a few , but today was my first . Lady down the road rang yesterday but I couldnt get to her . New gas and lecky meter fitted , they found the tiniest bit of soot on an ILFE and turned everything off .!! . She was surprisingly calm with no heat and hot water...
  12. T

    No earth bonding within 600mm of meter

    Hi guys how would you class no bonding within 600mm on cp12 as now no ncs, AR ?cheers
  13. rpm

    Water meter and card through letterbox

    The old dear next door is getting in a panic about workman in her house and I can`t find a recent post on it, can anyone remember the post? Why do they need to enter when the meter is outside? Thanks.
  14. I

    Cold water pipes blown apart - since fitting water meter

    Hi guys, My parents have a combi boiler which was installed about 12 years ago and has been working fine. The other morning there was a bang and water started pouring out under the boiler. I went over to help them out and had a quick look, 2 soldered joint on the cold water feed to the boiler...
  15. W

    Thumping manifold, bouncing flow meter

    I have a Rehau underfloor heating system on the ground floor only of my house. Every so often, the manifold makes a knocking/thumping noise. When I look at the flow meters I can see the one that's making the noise and the little ball in the flow meter is bouncing up and down (so the water...
  16. S

    identification of valve/ fitting prior to smart meter

    photo attached of valve / fitting I,m trying to identify i live in a second floor apartment cold supply if from a basement water tank pressurised by pumps the cold water supply enters our property (22mm copper) and immediately after the main stop tap is the fitting I am trying to identify and...
  17. C

    Imperial gas meter has 2 lead output pipes

    Hello all. This post is regarding the configuration of outlet pipes from an imperial gas meter both pipes are lead. A 22mm and a 15mm pipe branching off from it. Something I havent seen before. Has anyone seen this configuration before? Why the main pipe and a branch off? Is it best...
  18. M

    What type of meter is this lads??

    Never seen one like it before, how do you gas rate it??? A few doors down from where I was working....
  19. P

    inlet working pressure drop between meter and boiler

    Hello everyone I wonder if anyone could help me get some answers… Last year I had a new boiler installed. Before I had an old fashion boiler (installed in the lounge) so most of the system had to be replaced. Pipes run from the meter to a junction giving one branch to a cooker and one to...
  20. P

    Become a smart meter installer..

    I keep reading in trade mags and elsewhere about the apparent shortage of smart meter installers. I wonder if anyone on the forum has considered getting involved and if not,why not?