Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

pipe

  1. D

    Removing unused stack pipe

    Hi, Just wondering if the 4" stack pipe shown on the attached photo can be removed and capped at ground level? The bathroom was originally upstairs and now relocated to downstairs with the waste plumbed directly into underground pipework. Not sure whether this is still required for the...
  2. J

    What's wrong with this pipe?

    Hi All, I have these heating pipes. I think I have cleaned them last year and there is a lot of corrosion already. There isn't any water dripping and there is no dump coming from underneath as the floor is insulated with 25mm Celotex and SuperFoil on top as you can see. What should I do?
  3. S

    Advice on old Osma soil pipe boss

    Trying to connect up new 40mm waste into the old soil stack (which would be an absolute pain to remove), it's all Osma pipe, from the 70s. Pulled out the old waste from the boss and discovered the seal is pretty knackered, hardened and cracked everywhere (red coloured seal in the photo)...
  4. JohnnyZenith

    Looking to see what iron pipe part can fit a 10mm ball joint?

    Looking to see what iron pipe part can fit a 10mm ball joint? In this pic there is a part that connects the ball joint (or whatever they are called) to the 1/2 inch pipe. I am looking to connect to a 3/4 inch pipe. Are there any threads that do this? Thanks I have been told that in North...
  5. Marky22

    Old waste pipe size help

    Hi, came across this old push fit waste pipe. Stripped out the old shower and it was a 40mm waste pipe siliconed in the fitting. The fittings at floor level so I’d be looking to bend (90 degrees) straight away so I can get the lowest possible shower tray. Could someone advise what I could...
  6. kdrifter440

    Septic gases in crawl space from gap in pipe.

    A family member had a sewer line collapse, which brought to light several issues with their plumbing. There is a 1/4 gap in the sewer line where a 3 inch pipe and 90 sits on another 4 inch 90 going into the ground. How concerned should this family member be about septic gases in the crawl space?
  7. AntEpping

    Blocked soil pipe after installing replacement toilet

    Hi - I'm not an expert but wondered if anyone might be able to assist. I've replaced an old toilet with a new one. I've used the same water inlet pipe, and have just replaced the right angled soil pipe connecter (110 at toilet end to a 97-107 connector end to existing soil pipe). It's secured...
  8. N

    110mm plastic pipe fitting toilet solvent

    Hiya, my toilet has 110 pipe going to master boss fitting. It's not glued and loose. I think as it's going to master boss that's why it's never glued. It has one drop of water leak after every flush. What I can use to stop leak at same time in utue if It needs to be removed it can be removed...
  9. K

    Converting single to two pipe system

    Hi All I have a single pipe central heating system which was extended 20 years ago when we had an extension. The heating upstairs has never been great particularly in the extended part with only a few of the original radiators getting very hot. We replaced the downstairs radiators with UFH...
  10. abrogard

    Is pvc pressure water pipe okay for outdoor use?

    I've just put a second tap out in the garden and ran that 1/2" pressure water pvc to do it. Down from the first one, underground, up to the second. The up and down runs exposed to the weather all the time. Is that going to be alright or I should clad them or paint them or something, protect...
  11. B

    Leak on sink waste pipe

    A while ago I replaced a leaky, corroded sink trap. That all appears to be fine, I can't find any leaks with it, and everything under the sink appears to be consistently dry. The problem I have is that there appears to be a leak where the waste pipe out from the bottle trap meets the wall...
  12. RachelG

    Cutting copper pipe in a very tight space

    Hi everyone, I'm running copper pipework for my new bathroom and there's a spot about the isolation valve which is really tight because everything has to fit behind the wall until it can run under the bath and there wasn't much space as there's a sink there too. Made a silly mistake with the...
  13. fango7

    Pipe fitting from bathroom sink

    Hi all, Bit of advice needed. Waste water pipe from bathroom sink came loose last night caused some water damage to ceiling below. My question is the brown pipe seems to have came loose, but seems to have just been pushed into thread above.There is nothing holding it in place, is this...
  14. centurino

    Hide Pipe Recommendations

    What is the recommended way to conceal a 1.5M, 40mm shower waste pipe? We have 30mm gap behind the plasterboard which will be renewed. Would you chase the block 10mm or go into the concrete floor? What are the safety concerns of doing either? Thanks.
  15. U

    Pros and cons of running boiler gas supply pipe indoors Vs outdoors

    Hi all, Does anyone have any feedback as to which is best. Running the pipe from the outdoor gas meter to a new boiler on an outside wall or run the pipe under the floor (suspended timber) which is our existing setup and the new boiler is being sited in same location as old. I ask just in...
  16. S

    Broken pipe in the wall while removing bath spout

    Hi all, My partner and I recently bought a house and have been attempting to make the bathroom less fugly. I was removing the bath and shower taps to replace, but while removing the bath spout (which had no nut to undo), the threaded section of the pipe broke. I thought the bit that broke must...
  17. M

    Solvent weld glue on pipe/fitting

    I was just interested if people put solvent weld on both the pipe and fitting or just the pipe when glueing overflow/condensate pipe.
  18. B

    Microbore pipe showing above radiator!!

    Newish house with radiators that have microbore pipe but on one of them the pipe is sticking up above the radiator which looks unsightly. Is it possible to push the excess pipe back into the wall? I'm worried about causing a leak.
  19. S

    pipe runs - confliciting advice

    Can a kitchen sink discharge pipe starting at 60 cm height run for 4.5m, then join another sink discharge pipe at 51cm height, then continue for 11m discharging at 35cm height? I have kitchen-to-be 4m x 3m. doorway at 7 o’clock. Mini-sink at 5 o’clock. Main sink at 1 o’clock. Pipes run goes...
  20. J

    How much solder for 15mm pipe?

    Hi All, I hope you are doing well. I have this 3.25mm lead-free grade 99c solder wire. I know that the good practice to bend the wire before soldering so you know exactly how much it is absorbed by the flux. I know too little isn't good and too much is as bad. I need to connect two 15mm pipes...