Morning All
I have a Megaflo unvented cylinder . Water had been dripping into the tundish so I tried to recharge the air gap, but when I went to turn the pressure relief valve it would not turn at all, as it usually would. My shower has been dripping in the bathroom next door , could in anyway...
Can anyone help me identify which tap/connection it is to top up the system as the level has dropped quite a way below the red marker for the cold fill pressure on the gauge? Boiler was installed approx. 2014. I've looked in the manual & online but can't find anything. Many thanks
Hi,
I am trying to increase the pressure in my gas boiler and was under the assumption it just involved opening these two small black valves. I have tried this but the pressure gauge on the boiler hasn't budged? Anyone know why this is?
Hi all,
Just a quick question. I have a log burner and a gas boiler on a dual fuel system (Central heating and Hot Water) either can do both. The hot water tank I believe is a closed system but is on the same level as the bath. Therefore as you might guess the water pressure at the bath even on...
What the easiest way to find why my boiler is losing pressure. It is about 5 years old Vaillant combi boiler, we have just had 2 vertical radiator removed and refitted for decorating and now the pressure keeps dropping approx once a week. I guess a leak under the floor is possible, or trapped...
I have a viessman vitodens 222F combi storage boiler on the ground floor. It has 100l capacity inbuilt cylinder which is delivered on mains pressure.
I bought it hoping I could have two showers across floors running with hot water even if it’s a short while, while avoiding an unvented...
Hi, guys! Hope you are all well.
I have four solenoid valves connected to the main water supply, and they seem to break quite often. I believe it's the pressure that's causing this.
I was thinking of adding a pressure valve to control the pressure before it goes through the solenoid valve.
Do...
Hi, We have a large Heatrea Sadia unvented hot water tank, not sure of the size in liters but its about 1600mm tall.
The tank is around 3 years old now and was amazing when it was first installed. Around a year ago we had a problem with water dripping from the overflow pipe outside and we ended...
British Gas servicing the above boiler ramped up the boiler to maximum in the installer menu to do flue gas analysis.
They also measured the working gas pressure on the gas valve test nipple. This fell to 8mbar on maximum and 17mbar on high setting.
They then removed the isolation valve under...
Low hot water pressure
Hi everyone, I'm hoping someone is able to shed some light on my situation before I have to call out the professionals.
We've been in our house for over 3 years now, when we moved in the hot water pressure was pretty good (confirmed by a retired plumber family friend)...
Hi all not a plumber but am an engineer I have pressure drop in the system Worcester Bosch came back after repressureising the expansion vessel and he replaced the heat exchanger element. The boiler is coming up for 15 years old.
The boiler was going below one bar and not increasing when...
I was told by the plumber to keep an eye on the pressure, to ensure it stays above 1.0.
The red one is… but the black one is not…. What do the two mean?
Hi All, I replaced my existing washbasin bowl set with new Shaw and Mason forward bowl set spindles and chrome handles. The water pressure has reduced tremendously. when I opened the tap and tried running water directly it comes with full pressure. Also, if I open the spindle from the basin it...
Hi All, I have replaced my existing Shaw and Mason chrome set with the Shaw and Mason forward bowl spindles/ Handles. I have kept the same tap or the water dispensing unit. The water pressure has reduced after I made the changes. I installed the original spindle back but same low pressure. If I...
Hi,
Just had a "Main Eco Compact" combi boiler installed as the Biasi one failed.
It seems to work fine, gives a hot bath, i dont ever use the radiators or kitchen hot tap. (no point in upping the landlords gas bill for no reason)
On day 4, the pressure is below 1.
I filled it back up to >1, but...
I have a SIP space heater and fitted a new matching spec oil nozzle as part of a service on it.
I wanted to check the pump pressure with the new nozzle and its difficult to be sure what port to connect to.
And that these pumps are definitely adjustable! I turned an Allen screw which is not...
Can central heating / gas engineer expert help me with below issue.
During winter time only, I have been having issue with low pressure or pressure dropping with unvented hot water cylinder system.
During summer time there is no usage of central heating so the pressure at unvented system is not...
Hi everyone,
Gas combi Boiler
Mains fed in all taps and shower
How do I balance the water pressure in all faucets in my flat. Every tap/water faucet is mains fed but the cold water is really strong in every tap that if I open the tap fully it flies out like a fountain but the hot water is not...
Hi,
Looking to see if anyone can give some advice please.
My Baxi boiler has been losing pressure and I am having to top it up approx. every 4 hours from 0-1.5 bar each time. This has been going on a week now.
I have also started to notice small drips running down my condensate pipe...
Hi everyone, we have low hot water pressure in the entire house. It doesn’t appear to be a problem with the boiler. A Heatslave 25/32 External. The central heating works. The hot water runs for a moment before shutting off. Should I be clearing residue or air somewhere? Thank you, Abram