  1. M

    Radiator Not Heating Up

    Hi, Sorry if question already answered in previous posts, but I can't find a solution to the below: We recently moved house to a new home that has previously been extended. In one of the bedrooms that has been extended there are 2 radiators, one which looks like it was fitted when the...
  2. M

    Radiator half hot and half cold

    Hi all. I noticed this winter my living room rad only get hot in the top half. Radiator is 1600mm(DP SC) double panel single convector. System was flushed just last year. Both flow and return values are fully open and don't stick. Boiler is serviced each year. Baxi combi boiler about 8 ton9...
  3. J

    Undersized radiator opinion

    I have a slightly undersized radiator in my living room. The calculation says 6315 btus and my rad is 6019 btus. It was a replacement radiator, the same size as the previous one (so pipes were in the right place). There is a gas fire in the room as well. Should this undersizing cause a problem...
  4. D

    Radiator Heat Up Order

    I am trying to workout in what order my radiators heat up in order to then balance them. I am able to figure out which radiator pipe is the flow/return on each radiator so that I can then grab the right pipe to check which heats up first. There has been an extension done on this house at some...
  5. F

    Vertical Radiator Makes A Bang When Heating Up & Cooling Down

    Hello, I have a customer with a modern anthracite vertical radiator and a modern TRV and lockshield. The radiator makes a loud metallic bang from within the radiator, when it heats up and cools down. I have opened the lockshield fully, lowered the boiler pressure from 2.5 bar to just over 1...
  6. R

    Broken Radiator Valve, what's the solution?

    Hi Everyone, The metal spindal on the top of one of our radiator valves is snapped off and the radiator is always off, is there a quickish fix for this or will I have to drain the whole system to replace it, pictures inculded, thank you!!
  7. seweller51

    Vertical radiator not heating up

    Hi all. Could someone help with a issue I have been having with my vertical radiator. I have one vertical radiator in my bungalow and it does not heat up unless the surrounding radiators are shut off. I have tried turning the surrounding radiators down but the have to be completely or very...
  8. T

    Are radiator drain-offs now mandatory?

    My father is getting quotes to have his back-boiler replaced. The firm he wants to use have told him that they will have to fit drain-offs to every radiator as this is now required by regulations. Can anyone confirm that this is correct, and which regulation has changed to now require this?
  9. W

    Radiator replacement

    Hullo everyone its a while since I posted on here basically because i have had no plumbing issues however I have one now. My son recently moved into a house which has cellar within which is a radiator which is part of the central heating system. The rad looks old, rusty and horrible as does the...
  10. P

    Replacing a radiator and Valves

    Hi All, I need to replace a radiator in the kitchen, the 10mm copper has split so using this opertunaty to replace it with a towel one and also need to remove both valves and make the pipes shorter. Its a gravity fed system and the last radiator in the system , I have a bung kit, i know i can...
  11. R

    Free running radiator

    Free running radiator change. I currently have 1 radiator free running with all of the others fitted with TRV's. Problem is that the free running radiator is in the porch and I'd rather not pay to waste heat there. Question is will it be ok to close this radiator off and ensure that one of the...
  12. notsohandyman

    Radiator Sleeve Question

    Hi guys, These sleeves cover 10mm PVC central heating pipes (see picture and ignore tape measure) and I believe this is what makes it possible for the 15mm nut and olive to attach to take the radiator valve. As you can see they are installed before nut and olive. I've ordered a black towel...
  13. notsohandyman

    Radiator Pipe Advice Sought

    Hi all. The current towel rail is 1000mm x 600mm and ideally I'd like the pipes coming straight from the ground into the rail. The distance between pipe centres is 695mm. I can get a 750mm wide rail but the centres with that are 705mm and that additional 10mm could cause too much strain on...
  14. C

    Electric radiator settings for empty house 2 weeks over Xmas

    Hi ! Can anyone help with what I should set my storage radiator when I am away from mid December to early January please? I live in Bristol and have just dried out my small rented flat with a dehumidifier. I have a large radiator with the label NC3300 Auto Series C and the flat was built early /...
  15. C

    Simple radiator valve question

    How do I fit a Thermostatic valve to that?
  16. M

    Vertical radiator not heating up fully

    I am after an advice, please. We have a vertical radiator from Reina, Evie, that heats up only 2nd column fully, 1,3 and 4 are lukewarm. I borrowed a thermal camera and attached is the thermal image. System is balanced, there doesn't seem to be air coming out of the bleeding valve and was...
  17. P

    Bloc Feed pipe to radiator

    I have a badly blocked feed pipe to kitchen rad, was running very slowly but I’ve made it much worse trying to clear blockage with curtain wire, pushing the blockage to the manifold I think now totally blocked. Return pipe is clear. Exposing manifold is major as it’s between floors and involves...
  18. M

    Replacing Radiator with drain valve

    I want to replace a radiator that has a drain valve. Do I need to replace like for like and keep the drain valve in or can I replace with a thermostatic valve?
  19. G

    Adding a radiator to a mancave

    I would like to add an additional radiator to our central heating system. We have an attached double garage converted to a man-cave and workshop (with dividing stud partition wall) currently not covered by the central heating. The former is not currently user friendly in winter, and we get by...
  20. SteveRobert5a

    Basic Radiator Question

    I have a downstairs rad that has a 23 year old TRV and it's barely heating up. I bled it, and removed the TRV head and it still just gets a bit warm. It seems to be warm over all the rad, not just at the bottom. The rest of the system heats up fine with the other rads getting hot. It's sealed...