I have had some old radiators replaced. Having checked the btu calculation myself, the new radiator is slightly undersized. It should have been 6150 btus, and the k1 rad that has been fitted (the required width in order to fit the old pipes) is 6025 btus. Output wise the next rad up would be a...
I need to turn on a radiator and want to remove the valve top to put a spanner on it as it as it is stiff,
however the screw holding it on looks like a security screw as it has two holes in it.
Has anyone seen these before?
Hi, I have an electric towel rail which has stopped working. All the lights are flashing from blue to red and the boost light is flashing green I have tried re-setting it but still no luck. Can anyone help please? I have the manual for it and it’s a Smart version from Advanced Heating Solutions.
Hi, I’m looking for some advice on how to remove this radiator value to check if the pin is stuck. I have two similar values in the house where those radiators aren’t heating up at all. The pipe leading into the value is cold but the rest of the system is working fine.
Thanks for any help/advice!
Hi to all,
I have bought a new radiator as replacement for old one.
After installation by plumber, the new radiator is heating up only to 1/3 of high. The rest remain cold.
Also, radiator is making quite loud noise when heating up.
The system/radiator is free of air.
My plumber was...
Evening all.
I have an open vented C/H system with a heat only boiler and 10 rads over 3 floors.
I checked the system mid summer and all was ok. Now one radiator won’t get hot. ALL rads contain water, I have bled all rads. No hot water getting to flow pipe of cold rad. All other rads are...
I have recently bought my own house and decided to redo the kitchen. There was a radiator in the room already but I wanted to move it. I extended the pipes (8mm microbore) and plumbed in the new radiator.
I opened the isolation valves and filled up the radiator with no issues. I've bled every...
Hi Everyone,
I hope someone might be able to help please. I hope this isn't a daft question.
I am trying to remove the side panels on my radiator to get in to clean it, but they seem to be secured by a small screw underneath (on the valve housing).
Can someone please advise me if I can just...
Hi, I have a combi-boiler system and while I did some plumbing many years ago I have never fitted a combi-boiler and am confused by this problem . I removed a radiator on the upper floor of my house to clean and paint the wall behind it, when removing it I shut down the lockshield and packed the...
Hello all,
I live in a flat that has communal heating through a single pipe system. I recently had replaced a deco flat panel (waffle) radiator with a more mundane type 22 panel radiator. The problem is that the new radiator sort of worked in the beginning, but it does not emit any heat now...
Hi All, would appreciate some advice on next steps with conservatory rad.
Single conservatory rad not heating up at all, neither pipe getting warm. All other rads in house working fine. So far I have checked the TRV which is not seized and also adjusted the lockshield which is also not seized...
Hi All,
We renovated our house in 2019 and put in completely new plumbing system and piping including new boiler and 9 radiators. Off those, there is one radiator in the living room which does not heat up at all. I have tried balancing myself and also had a professional come in to balance it...
Hello all,
I've just had a new radiator installed and it comes on with the heating as expected but then also came on when the hot water came on without the heating.
Ours is a system boiler worcester greenstar 30cdi with an unvented cylinder. The new radiator has been hung in the w/c on the...
Hi,
I'm looking to add some radiators into my property and ideally looking to match the style of the existing ones. I cannot seem to find anything online to match. I assume this style of radiator is no longer manufactured, but I might be able to pick one up second hand.
Can anyone help me...
Hi folks. I need to replace a few rads, about 30 years old. Any advice on best quality rads appreciated. I got a quote from City Plumbing for their Halcyon rads, made by Stelrad ... the guy told me they are the same as genuine Stelrad, but cheaper. A good bet? Thanks.
Hi All,
I have two sets of radiator pipes that need removing. Although neither set of pipes have radiators on them anymore they are both still connected to the system and contain water.
A plumber I have spoken to says to remove them he'll cut the pipes vacuum out/up any water and then cap them...
Hi so I changed a towel radiator in bathroom from a normal radiator.
I bunged the f&e tank and vent pipe , drained about a pint of water out the pipes.
Altered the pipes to the new rad.
Then removed the bungs.
Gone to bleed the radiator it filled slightly now no air is coming out.
I've...
the thermostatic controller has snapped off the top of one of the radiator valves is the threaded metal collar standard to all valves?
Can I fit one fro a different make?
I bought the a bleed valve from S****fix about a year ago:
s****fix.com/p/radiator-vent-blanking-plug-nickel-2-pack/40972
It worked fine initially, but I noticed that the little bleed screw needed to be turned a little tighter each time I bled that radiator to seal it up again. Having bled it...
I am planning on replacing a standard radiator with a designer style vertical radiator in anthracite. I will need a high output of 6000BTU plus.
I have researched online and I am struggling to find any consensus on what is a quality radiator brand to select from. I’m not necessarily looking for...