radiators | Page 10

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

radiators

  1. B

    Radiators hot at one end and cold at the other.

    Hello. I need a bit of advice please about getting heat through to 2 radiators. All the others are piping hot but these 2, in adjacent rooms (bedroom & en-suite) are piping hot right the way up at one end and stone cold at the top at the other end. There's a hot band for the bottom third of the...
  2. O

    Good Value Column Radiators - (milano windsor range ) Help

    Hi, we are currently trying to source radiators for a new build. We have found the Milano Windsor range on the best heating website. They seem to be about the only column rads in our budget range. Has anyone any experience of them?. We are a bit concerned about buying online. There is a...
  3. Nicola84

    Radiators smell when on

    Strange question but when my radiators come on I can smell a sort of burning dust smell, I've cleaned behind them however I can still smell it a few weeks on, is this normal?( I know when the heating as come on as I can smell the hot metal)
  4. D

    3 radiators on 15mm branch?

    I was wondering whether it would be a good idea to replace some 15mm pipe with 22mm. I currently have 3 radiators on a single 15mm branch. Small, medium and large, approx 10,000BTU's at 50C in total. The room with the large radiator is always cold in the Winter, partly due to insulation but...
  5. T

    Radiators upstairs in dormer bungalow - Gravity system

    Gravity system. 2 rads and 1 towel rail. Base of F&E tank to top of towel rail approx 300-400mm Base of F&E tank to top of rads approx 800mm All stone cold when heating is on, although the customer tells me that after the heating has been on for about 3 hours they do start to feel warm. I...
  6. I

    TBOE radiators in new build incorrectly piped

    Hi everyone, I am seeking some advice. We moved in last year to a new build flat which has 6 TBOE radiators with TRV's at the top. The new build flat uses a heat exchange unit as it is connected to district heating system. All pipework is behind the plasterboards and run up in the ceiling. I...
  7. P

    Ufh problems temp control and radiators temp

    Hi guys Our recently installed UFH system is causing us trouble and we are struggling to get the fitter to help, problem one is we have to slowly build up the heat as the new floor is tiled but the only way to do this is by turning the boiler heating controls down as low as it goes, 30 degrees...
  8. D

    Emmeti manifold to new radiators.

    Hi I'm I've just joined and hope to gain some well needed knowledge! I'm replacing the old 1 pipe heating system in my house as its very old and full of leaks! We're putting down a solid wood floor so I don't want any joints under it that might fail! I'm thinking of using the Emmeti manifold...
  9. C

    Radiators Question - Should I Change Them?

    Hi, I had a new boiler (Baxi Duotec) installed with radiators a while ago. One room stays fairly warm and that has one of the original rads in it. All the others were replaced and the other rooms seem to not stay so warm. I said at that the time, this seems to keep the heat for longer and he...
  10. P

    Re using cast iron radiators

    I'm the maintenance guy for a client who owns a 1930's ex toffee factory which is up for redevelopment into housing. In the empty office building and ex social building there are cast iron rads that they are heating to stop freezing. I've advised them to drain them but they tell me that the...
  11. C

    Noise in radiators (closed system) when hot water run

    Worcester Bosch 37 combi boiler on a closed, two zone heating system which in itself works fine - all radiators hot, quiet etc. However, whenever there is a hot tap or shower run there is a small "gurgle" from one radiator when the tap is turned on, and another much louder "gurgle" around a...
  12. T

    Bad Crackling in some radiators

    Plumber fitted an auto bypass a few weeks ago and put some more inhibitor in after I asked him to. Since then the radiators have started crackling really badly when heating up. I have tried bleeding them and it seems to be coming from the side of the radiator without the trv and the valve there...
  13. R

    Random radiators stopped working after cold weather

    I have a Worcestor Danesmoor boiler that lives in a stone outhouse and heats the water and radiators in my house. The heating is set to come on at certain times of day, but during the recent cold weather it stopped coming on. I tried pressing the manual reset button a few times, but assume...
  14. B

    Issues with new radiators heating up!

    Hello! I've recently installed 4 new radiators in an extension onto an existing system. The system was put in by a builder which made me suspect to the pipework. I T'd off the 22mm primaries (after zone valve) and ran 22mm into the new extension then ran 15mm pipe in the floor (lagged) for the...
  15. A

    8mm microbore, twin entry radiator valves and ancient radiators

    Friends, romans, countrymen Spartacus.... few things going on here. as per the title i have a central heating system running through 8mm microbore copper piping to old cast radiators using the completely redundant twin / dual entry radiator valves. not ideal i know. on the positive side the...
  16. S

    Radiators cold at bottom

    Hi everyone Looking for some advice please I have Worcester Bosch green star 38cdi classic HB combi boiler. It’s only a few years old and has a magni clean thingy fitted to collect the metal etc. I have bled all radiators most rads bar 2 small ones 400mm x 400mm (old) are all brand new 2...
  17. S

    Leaking joint on Aluminium radiators

    Hi, Where the valves screw into the aluminium rads has started to leak (all be it not that much). The system is a ordinary pressurised sealed system. The leak is hardly enough to drop the pressure. The system has been fine for 4yr+, I guess that the rubber gasket has started to fail. I have...
  18. K

    Radiators don't stay as hot as when first on

    Hey hoping someone can help me out with a question I have with my central heating. When I put the heating on the rads gets nice and hot but once on for a an hour or so they cool down a bit still hot but not as hot and takes the house a while longer to heat up. Also the kitchen radiator I...
  19. J

    2 upstairs radiators need bleeding everyday

    Open vented system 2 upstairs radiators need bleeding everyday First tried turning pump speed down from 3 to 1, but problem persists. Any suggestions would be appreciated.
  20. G

    Radiators Turning on when should be off

    Hi all, any help appreciated on this issue I have done a google search and I see that there could be an issue with the 3 port valve or more uncommon a reverse circulation issue. The Boiler model is the I-Mini C30 and the problem seems totally random, it started in the middle of the night once...