radiators | Page 9

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

radiators

  1. S

    Rattling pipework and radiators

    Hi. I have had this noise for 5 years and have had a plumber check it out and he said it could be a bit of solder in a pipe thats rattling and is impossible to find. I gave up getting the noise fixed and have lived with it. A quick run down of what happens is when the thermostat kicks in and...
  2. G

    Two radiators not heating up after bleeding. Flushing of system required?

    Hello there all mighty and knowledgeable central heating warriors! I have two radiators in my duplex flat which fail to heat up. One is a large vertical radiator in the living room, the other is a small ladder style radiator not too far away in a downstairs toilet so both on the same floor...
  3. M

    Solid fuel central heating - no heat in radiators

    I have moved into a house that has a large wood burner connected to radiators for the whole house. The pipes go up into the attic and there is an overflow tank there. The radiators are not heating up at all. The pump comes on, but the water doesnt seem to get to the radiators. Also, theres a...
  4. G

    Cold Radiators Downstairs

    Hi, I've had this problem for a while. I have a fully pumped system with 3 way divertor valve. I have hot water and hot radiators upstairs. All radiators downstairs are cold (6 rads). A new pump was fitted, I have flushed the system with Sentinel X800 and X400. Also power flushed system...
  5. M

    Radiators with small brackets

    I need to fit a couple of radiators in a property. The only issue being the skirting is about 400mm high and don't want the radiators looking ridiculously high. They don't want the skirting cut to accept the brackets. So the question is, what brand of standard radiators have brackets highest up...
  6. milleniumaire

    Cold radiators in loft

    Hi, I've have a problem with my CH system for around 18 months now and it's time to get it sorted. Here's a diagram showing our current heating system: The house is 21 years old and the loft extension was performed around 15 years ago. As you can see they simply extended the existing 15mm...
  7. R

    Drain down central heating and refill with radiators off

    Hi, I have probably done a silly thing here so need some advice. I drained down the central heating system with a hose pipe from the drain off on the radiator closest to the door. No problems. Then I removed 3 radiators as we had the decorators in for a few weeks. As the decorators...
  8. R

    Radiators heating up on DHW setting

    Since replacing the expansion vessel on our Viessman 333 gas boiler, we've experienced a major problem. When we want hot water only,(DHW) setting, the radiators are being activated! Obvious solution may be with the 3 way port, but the complete heating system is now automatically switching itself...
  9. A

    Very hot water and radiators after Summer.

    Suggestions please. I have an puzzling problem. I switched off hot water and CH in Summer. Baxi boiler. After a short period of turning hot watertap on the water was scalding. Assuming hot water coming from hot water tank? I switched on hot water and CH but hot water is still scalding and...
  10. P

    Advice around buying designer radiators

    Hi Guys I'm new to this platform and trying to do some market research for my start up company poshrads.co.uk and reach out to potential tradesmen/plumbers My question is how often are you finding customers are asking for designer radiators as to a standard convector standard rad if so where...
  11. Ryooo

    Help 2 radiators not heating up

    Hi there, just spent the best part of 3 days in only what I would describe as "a big hoose" domestic 60 kW boiler. The client wanted 2 radiators added, 1 radiator added in master bedroom and 1 added in bedroom 2 that was the son's nursery. Completed the works today. The existing system is mild...
  12. A

    Advice on flow to radiators after new boiler

    Hi All, I am looking for a bit of advice. I am not a plumber, just a DIYer who has been doing his own plumbing for more than 40 years. I understand how central heating works with flow and return but have a bit of a potential issue which I want to discuss. Bit of background first. I had a...
  13. G

    Boiler with no radiators

    Hi, Is it ok, after draining the system and removing all but one radiator to turn on the combi boiler, in order to get hot water, until new radiators are installed? I've left the pressure at 0 so haven't filled up the system and have put capnuts on each TRV side just in case. (Couldn't get...
  14. J

    Barco Radiators - Bunkrupt

    Just heard Barco radiators went bust. Wolseley said that all their stocked items (inc. special orders like designer rads) were zeroed off their system and they weren't allowed to sell them. Just so you know. J
  15. D

    Two out of three radiators not heating up

    Hello — if anyone's got any ideas on this one, I'd be hugely grateful! Here are the details... I live in a small one-bed flat (on one level). Last year I had the water tanks and immersion boiler removed and replaced with a Vaillant EcoFIT combi boiler. The fitters rerouted the pipework as...
  16. B

    Radiator TRV 15mm but radiators 22mm??

    hello, not a problem I’ve thought about before, but having an achp fitted so I need the maximum flow and return volume. However I find I can’t get 22mm TRV/ emitter valves only the standard 15mm. This seems bizarre due to the standard emitter Inlet/ outlet bore size. Will this cause much of a...
  17. D

    Radiators boiling but no hot water from taps

    We have a coal fired Parkray room heater, running 6 radiators. They are all red hot but there's no hot water from the tap. What should I do? I'm quite nervous about the back boiler blowing up.
  18. E

    Stelrad Compact Radiators vs Stelrad Softlines

    Hello, can anyone tell me if there is a difference between Stelrad Softlines and Stelrad Compact radiators - if there is a difference what is it. I am thinking of getting some for my house and am wondering which to buy.
  19. S

    Advice needed! Heat to radiators even with heating off

    I really would appreciate some advise please.. If our boiler is on then our radiators are on, even with the thermostat off. The separate control panel which controls heating and water is off too. This is an ongoing issue..... We called out a heating engineer previously, and he replaced a valve...
  20. O

    'Radiatoroutlet.co.uk' column radiators?

    Has any of you had experience of 'radiatoroutlets.co.uk' column radiators? The advertised output BTU are impressively high. I asked them and they said they are rated at T50 which sounds better again. It would be good to get some independent reviews/experiences?