Homeowner here, I'm NOT a plumber, but I was hoping I could find someone on a forum to help me as I've had high success rates in the past with this.
Please see attached pictures.
So one morning I was taking a shower, and the handle straight up snapped off. This is what I am left with. I could...
I have an old FF360 I was thinking about replacing, but in the end it just does not seem economical. It is rated at 78% efficient, so I suppose a new boiler might be able to shave 10-15% off the gas bill, but would that realistically pay for itself? It looks like parts for the Ideal are still...
I have a very old Gloworm boiler. Been advised by gas engineer to replace for modern unit. It's working fine but worried about availibilty of parts and getting a plumber to work on it. Any advise ?
Hi plumbers and DIYers
I made a post about my 3-port valve a couple of weeks ago, but have finally been able to take a look and thought best to start a new one than tag on. Hope that's ok.
Recap: We've had a problem whereby our boiler will only heat the radiators, even when set to hot water...
Hey guys,
I have a one-exit water valve under the sink leading to the cold tap above. I'd like to replace it with a multi-exit valve so that I can connect the dishwasher to the main water-line. Fine, I thought. I've got myself a multi-exit valve and just need to remove the old one.
This is where...
Hi again
I'm on a roll with the plumbing questions today! So here's query #2...
We've not used our hot water for quite some time, and it now doesn't work. From what I can gather based on what I've learnt in the last hour or two, I think the problem is with the 3 port motorised valve. When...
Hi all, I was reading about these new microwave boilers that are due to come out from Heatwayv (A new way to transform how we heat our homes | Heat Wayv - https://www.heatwayv.com/), they seem to be a drop-in replacement for your old gas boiler, but with electrickery costing about 5 times as...
Hi, I've been trying to find out how to release the retainer nut on a watersmith (Screwfix) mono bloc basin mixer tap. It does not have a hex nut but rather a recessed nut with two flat pieces opposite each other and elliptical the test of it. No space for grips, adjustable spanners etc. I've...
Hi.. Advice please regarding a new Worcester Bosch 8000 Life 35 for a 4 bed detached with ensuite and currently powerful shower which is great. We currently have an old High Flow 400 . I understand heat output will be the same on a 40 / 45 / 50 model but will the 35 be sufficient especially...
My daughter has all electric heating, however, the lower economy 7 immersion has failed (high resistance short to earth).
I received what I consider a ridiculously high quote of over £400 to drain the tank and replace both immersions (upper boost immersion is working but 8 years old so I assume...
During my shower yesterday the pump stopped working. The Aqualisa Aquastream was installed approximately 10 years ago and has been very reliable until now and has been a great shower. I changed the 3 amp fuse in the switched socket in the airing cupboard and the fuse is not the problem...
Slightly daft question when you can't tell the size of the space but I'm wondering if I should replace this 32mm compression coupler (circled) with a solvent weld connection? It was installed by a professional a couple of years ago but I've noticed the pipe twists a little, I noticed this when I...
Hello guys,
Struggling to find a replacement radiator. It measures 1155mm at the widest, i'm not too bothered about height but preferably around 300-400mm.
There are plenty of radiators around 1164mm and 1010/1100mm.
There are some column radiators at 1149mm but £300 each so I may have to go...
With a thermostatic mixer showers, can you replace
the unit, in a mains pressure unvented system boiler
configuration, by just turning the cold mains off
at the stopcock when the water supply enters the
property? Will the hot and cold water stop flowing
if you turn the mains water off?
Onto my 2nd loo that’s currently turned off as it’s constantly flowing into the pan. Grohe concealed but with no flush plate. Flush panel removed. I attempted to pull out the flush valve to source a replacement but the stupid previous owner put the countertop on too low down and it won’t come...
Hi, any help appreciated with this, ideally would like to avoid having to rip out and replace full bath, would just like to find replacement panel, but struggling with this
Measurements seem weird
Length of panel = 1690 mm
Height of panel = 535 mm
Length to start of curve = 620 mm
Size of the...
Our Salus RT505TX seems to be failing according to Salus as the battery low icon won't turn off even with a reset. It was fitted 7 years ago with a Worcester Bosch boiler, the boiler is fine and we hoped the thermostat would last at least as long. They suggest a RT510TX/RF but we are looking at...
Hi guys
I have replaced some of my Drayton TRV’s with the smart Tado TRV’s. However I have this installed in the kitchen radiator, the others I just basically unscrewed and screwed the smarts ones, but this one looks different to the chrome Drayton one (see pix)
My question is can this be...
Hi
Looking to replace the Baxi 105E microswitch but Worried about getting the white connectors off without damaging the wiring.
has anyone done it and if so is there a trick to getting the connectors off?