  1. P

    Pricing to replace a vented cylinder with an unvented cylinder (megaflo)

    Hello , ive recently gone out on my own, i have been working in the industry 15years now /g3 qualified and i would just like to get some advice from the knowledgable people on this forum! i have done a lot of installing but haven't really got involved with the design as somebody else has done...
  2. J

    Should I replace central heating pipework.

    Hi This is my second question and follows on from discoveries made while investigating dropping flow rates where you guys contributed a lot. I have made an access point to the crawl space and had a look around. Let me say at this time we are a living in a cottage so all is on one level. A...
  3. C

    Copper pipes gone black, clean or replace?

    Hi all, I had the house redone about 1.5 yrs ago and all new plumbing was installed. I have plastic pipes in general except copper pipes in the cellar where the boiler and water tank are. The copper pipes have now turned black but the black layer comes off with sandpaper or emery paper. I've...
  4. A

    Need a plumber to replace a kitchen tap - Leeds

    Hello, I need a plumber to replace a kitchen tap. I'm based in Roundhay, North Leeds. I tried to do it myself but couldn't get the nuts undone on the pipe (posted about it in this forum), getting the tap itself loose wasn't a problem. It's flexi-hose and looks like this under the sink (pic...
  5. A

    Liverpool New boiler and pressurised cylinder replace exist boiler in new location.

    I need a G3 qualified Heating Engineer to supply and install a new Vaillant 32kw ecotec central heating boiler with Green iQ system Vaillant smart heating control. Building has two bathrooms and one shower room and I want to increase ensuite facilities to four other rooms at a later date...
  6. L

    Can i replace a triton cara shower

    Can I replace a Triton cara shower with a Triton enrich shower? Are the connections etc the same. Dont want to affect the tiling in the bathroom.
  7. R

    Faulty GRUNDFOS ALPHA2 L 15-60 130 replace with Grundfos Alpha 1 15-50/60

    My GRUNDFOS ALPHA2 L 15-60 has developed a fault and I'm struggling to find a replacement to enable a simple swap. Would the Grundfos Alpha 1 15-50/60 be a suitable alternative? I'm hoping to simply remove the faulty one and install this without having to do any further work! Many thanks in...
  8. J

    How replace the washer on this tap?

    Hi, I have this tap and it is dripping. It's quite a complicated tap and I have no idea where the washer is and how to replace it. Can anyone help please? I've put a shot of under with the tap where the water comes out. I don't know whether there is a big hex hole up there and maybe that's the...
  9. L

    How to replace cold water supply line without using a torch or soldering any fittings.

    I would like to simply cut the flex copper pipe off just past the cut-off valve and attach a Shartbite male fitting or a compression fitting on the remaining copper stub which would be 7/8 inch in length after the cut. Would that meet code? Live in North Texas. Thanks, Don
  10. B

    I want to replace my groundfos mq 3-35 with same need a few tips?

    Ok got my heating back on, got cold water ok, got an electric shower, of the 3 toilets 2 fill reasonably quickly, the third is just a dribble and its near the booster. So I will order a new Goundfos mq 3 and re-install as like the old. I have seen u tube but mine is a gravity feed so how do I...
  11. B

    PRV valve loosing pressure. Just replace..again?

    Hi, We have a Glowworm 38CXI combi boiler. Back in September last year I noticed that it was losing pressure and I was having to re-presurise it almost daily. From looking outside I could see the pipe coming from the PRV valve was leaking quite a bit. As such I got a plumber in to check over...
  12. C

    URGENT Old radiator and no key, how do i bleed or just replace?

    I have a very old radiator for which we cannot find a key for. It desperately needs bleeding, any ideas on how I can do it or is it time for a new radiator?
  13. C

    How to replace an O ring on a flip over/swil type basin waste

    We have a flip over hand basin waste plug which won't close properly, I think the O ring has swollen. Can anyone let me know how to replace the O ring/remove the flip over/swivel plug?
  14. K

    How to replace seating washer on Hardie Bathroom products cistern

    Hello, I am in Australia and I have noticed a leak from my cistern into my toilet bowl. Upon investigation I have surmised that this is due to a failing washer. The washer appears to be disintegrating as there are many small black pieces of rubber in the cistern and it flakes easily when...
  15. T

    How to stop a pan connector leaking when you can't remove the toilet to replace it.

    Hi all, I'm hoping the title says it all - I've got a low level toilet in an old-fashioned community hall that is concreted to the floor and the pan connector is leaking. It's only a small leak thankfully but there's no way to get the toilet out without breaking the pan and opening up a world...
  16. G

    When to replace old analyser

    My anton evo2 now needs a £250 service with new oxygen and carbon monoxide sensors. My first thought was maybe I should just replace it. Do the service bills get bigger than this?
  17. S

    Help required to replace broken toilet cistern push button

    Hi there, I was hoping you lovely people could help me to identify this toilet cistern push button system below, so I can replace it or get something similar. The internal push button is completely broken, but would I need to replace the whole part of the cistern section with the external push...
  18. N

    If I replace CM927 will it work with the existing Relay box?

    Hi. CM927 Wireless programmable Thermostat and Relay box were fitet in my house Sept. 2008. Now the CM927 seems to misbehave, If I buy a replacement CM927 will it work with the existing Relay box?
  19. S

    Replace Kitchen Tap with fix copper pipes with one with flexible pipes

    Good evening, In my kitchen I have got a tap with fixed copper tube that they fit in a plastic but in grey ( see picture1). Can I fit in the grey pipes this tap with flexible pipes? Is there an adaptor between them? What is the name of it? (Picture 2) Thanks
  20. davidw

    wi fi programmer to replace old switchmaster SM600

    Hi All, Merry Christmas and a great New Year. I want to change my old Switchmaster programmer to a newer easier to use wi-fi controlled model, something I can adjust from my phone or laptop and not have to crawl about in my airing cupboard! ( I'm too old for that stuff). Can anyone recommend a...