service | Page 6

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

service

  1. P

    what and where is the 'boiler CH service valve'?

    Reviewing the Valliant ecoTEC install manual, and steps noted in this book for re-pressurising the internal expansion vessel states the following - Ensure the boiler CH service valves are closed. - Release the pressure from the boiler. - Remove the valve cap from the...
  2. quality

    Gas service .

    We did some working in a property with what looked like a mechanical/compression connection on the gas service? is this allowed? it was external and had a service supply as standard I didn't take a photo but jut looked odd to me
  3. Pickwickpick

    Seized Mira 88 which service pack

    I've got a customer who needs a mira 88 servicing. It had stopped regulating temperature properly for a couple of months and just recently its completely seized up, the dial will not turn. There's two service packs available, the cheaper one (936.12), which has all the o rings, spring, spindle...
  4. G

    New member for boiler service help/advice

    Im a boiler service engineer, joined for advice and help others if need. Ive started a channel for boiler service modes. So if you need or interested please check them out Gold Gas ^^^click here^^^ Peace!
  5. G

    Boiler service modes (how to)

    Hey gang, I'm a boiler service engineer. Just started a channel for boiler service modes as i struggled to get some system and heat only boilers into max/high fire mode. Its live, so I'll be always updating with more. Gold Gas ^^ CLICK HERE ^^ Hope it can help some fellow service engineers...
  6. D

    Dripping in Wall cavity after boiler service

    Hi, I'm after some advice if possible please! We had our Combi boiler (in kitchen) serviced for it's 3rd year last week & since then we've noticed a fast dripping sound in our sitting room wall cavity when the heating is on! It slows to 1 drip per 40 secs once heating turns off! Our house was...
  7. S

    IntaKlean Service/cleaning

    Hi everyone. I'm hoping somebody will be able to offer some advice. I've recently moved home and above the boiler is a Inta Klean triple action magnetic vortex filtration system installed. Doing a bit of research I now understand what this gizmo does but it seems to clean it the engineer needs...
  8. G

    Start-up Bangs & shut-down pops AFTER service.

    Start-up Bangs & shut-down pops AFTER service. Potterton Boiler C50/15 (circa 1972?) Our Potterton stopped firing and we had a GasSafe bloke diagnose a new Honeywell V4400 valve & thermocouple. Fitted these and now it fires-up, silently. I can hear the boiler stat click. Yet, every 10-15th...
  9. O

    Baxi Megaflo 2 System / 24 compact service kit

    hi guys, As the titles states, I am after a service kit for a Baxi boiler. I never serviced a Baxi boiler and therefore I am Wondering if there is a Baxi service kit to but like Vaillant. What kind of things would you change or service when doing servicing a baxi boiler? Kind regards, Ron
  10. O

    Annnually Service HIU

    Hi lads, I just wanted to ask you is there any annually service for HiU boilers? If that’s the case what would Service and what parts should be changed in order to make a good service. Kind regards, Ron
  11. H

    Service Engineer Required - South Somerset

    We’re a medium sized family run plumbing and heating firm with over 40 years trading history. We’re looking to employee a gas, lpg and oil service, repair and installation engineer. Ideal candidate will have over 10 years experience as a plumbing and heating engineer, be able to work...
  12. B

    Will comfort series pressurisation unit service reset

    Hi all, Anyone know how to reset the service hours on the wilo comfort series pressurisation unit. Have the manual for it but it doesn’t say anything about resetting the service hours on it. Thanks for any help
  13. M

    Engineer needed to service and replace expansion tank losing pressure. Chesterfield De55

    Hi, I have a sealed pressurised tribune system and it is losing pressure. I’m pretty sure the expansion tank needs replacing as the Schrader valve won’t do anything when pressed. I’m also after a general service At the same time. Chesterfield area, can anyone help?
  14. king of pipes

    Who does this on a logic + service

    This one got missed last year so full strip flush through the heat ex new electrodes and gaskets good for another year . Cheers kop
  15. A

    Oil boiler service Hingham Norfolk

    Hello, I have a Worcester Heatslave 15/19 oil fired boiler that I would like to get serviced either tomorrow or Saturday I am based in Hingham. Thanks
  16. B

    Unhappy with my boiler service or am i being fussy? - advice please

    Hi, I’m after a bit of advice please. I recently found a Gas Registered small firm to come and service my Boiler and Mega Flo. The chap turned up and his gas safe card showed he was qualified for all the aspects he was undertaking. My boiler is a Potterton, last serviced about 18 months...
  17. Inverness

    Worcester ri 24 service mode max wouldn't fire but blue flashing light 5 times

    hi guys, went to carry out a service... went to high fire setting mode but nothing happened? Blue flashing light 5 times.. checked condensate not blocked.. flue good.. Reset the thermostat knob but nothing happened. Standing gas pressure 25mb to the gas valve.. When I put the heating on from...
  18. C

    Worcester 28CDI Service Confusion....

    Hi all, i went to service one off these today but i had to abandon and say i'll be back in a couple of days. This has really throughn me badly and its the first time i've attempted to service one of these aswell so no prior knowledge. A bit of background british gas have "serviced" it for the...
  19. T

    Boiler Service - Peterborough

    Boiler and unvented cylinder annual service required in Glinton, Peterborough.
  20. S

    Reset danfoss fp715si service reminder

    afternoon people, any of you good folk know how to reset the service reminder on this timer. It’s on my mates timer and driving him bonkers Thanks in advance
Back
Top