Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

service

  1. Inverness

    Vokera linea 24 service

    Can someone explain what this is for in these boilers Minimum Adjustment Potentiometer ? I'm servicing one tomorrow. I'll clean it out check all seals,tightness and letby test, burner operating pressure at max with hot water no more than 10 mb on max and then c h on min 1.9 mb I think. There's a...
  2. Inverness

    Worcester service cleaning n removal tool

    hi guys. Iv managed to make my own Worcester service tool instead of paying for the actual Worcester tool. Anyone else made there own?
  3. Scott_D

    WB junior full service

    I need to give one of these a proper service, it's not had one before and the FGA readings are getting high. Do I need anything more than Brush kit Burner gasket Electrodes
  4. P

    Cold water leaking through tundish after service of cylinder

    Hello, We have had our unvented cylinder serviced for the first time a few days ago (the whole heating system is brand new, well one year old :)). Soon after the service I noticed cold water dripping through the tundish. The company who did the service sent another engineer who said the...
  5. H

    torque wrench for service

    anyone use a torque wrench when replacing the gasket on burner door after service or repair if so what Nm settings do you use
  6. gingalig

    Worchester 32/50 utility boiler service

    Hi I just serviced a a 32/50 greenstar utility, my first as I’ve only just registered with Oftec. My question is are they usually so filthy. It wasn’t serviced for 2 years apparently but I’ve come away looking like a chimney sweep. It took me far to long but half the time was cleaning the thing...
  7. M

    First vaillant green iq 627 service of system boiler.

    I have a service for a vaillant 627 system boiler(eco tec pro). For a first service I was told(for 65 quid) you'll need a burner seal . Service and new G10 seal £65 , Thanks Is this correct as to what I need- when he hasn’t checked boiler?
  8. J

    Can anyone service my gas fire - no tools/info left left by seller - Gazco Eclipse type

    I have inherited what looks similar to the current Gazco Eclipse gas fire but the sellers left no instructions. I have had 3 gas engineers in the house but none are familiar with the model and specifically how it is opened/accessed to begin with. One did say it looks like an allen key...
  9. missplumb

    Biomass service engineer opportunities

    Highland Wood Energy (or HWenergy) are wanting experienced biomass engineers and field technicians in all areas of the country.
  10. Last Plumber

    Freezing Machine Service,

    How much does it cost to have a Rofrost Turbo Serviced ? Where did you send it ? How long did it take them to get it back to you ?
  11. L

    CH Filter - Manufacturer Refurbished & Re-certified + Service Kits + Inhibitor

    For Sale 1 x Manuf. Refurbished/Recertified - ADEY Twintech (RRP £110.00) 5 x Service Kits (RRP £11.47 each - Brand New - total value £57) 2 x Brand New Valves 2 x Spanner/Wrench Additional MC 1+ Adey Protector 500m Bottle (RRP £10 - New) DETAILS: CH installer had advised & charged us for...
  12. D

    is an ECV actually mainly used as a Service Valve ???

    Just need some clarification as to this, if you have a new meter fitted the ECV is used as a service valve , if you need to carry out work on the domestic system you use the ECV as a service valve ..... is the ECV's most common use A SERVICE VALVE ???????
  13. Stanios

    Worcester Bosch not so great customer service

    One of my regular customer rents out a house with worcester bosch air source heat pump that does heating and hot water. I am quite an amateur when it comes to anything other than gas this is in fact the first air source pump I've seen in a domestic property. The unit started having trouble...
  14. J

    Tips for Main water heater service

    Hi all, I'm due to service my first Main water heater next week. I haven't taken one apart before, so I'm a bit apprehensive. The boiler is two years old, but the flame picture has a yellow tinge, so a good clean is in order. Most of it is straightforward enough - until it comes to the funny...
  15. S

    Service engineer looking to start installs advice

    Hi i am currently gas service and repair, havent really required any powertools, I have got pflush machine, looking to go a bit into installations, what set of tools would i need for just boiler swaps? I am looking into sds drills and to be honest know. Nothing about them, ill need a core...
  16. A

    Boiler service advice

    Hi All looking for some advice. Boiler has broken down after 20 months but has a 7 year warranty I have had the unit serviced but just noticed when looking at paperwork the the print out is dated October 2017 when the service was carried out in October 2016. Does this matter or is it just a case...
  17. B

    Choosing a combi boiler - customer service & boiler quality

    We have recently bought a 3 bed terrace which currently has a 9yr old Vaillant ecotec plus 415 which heats the radiators and water storage tank in the bathroom. We are wanting to change this for a combi, change out the 7 old single panel radiators for double convector units and install a shower...
  18. G

    britony IIT water heater service in TW7 Isleworth

    Anyone know someone that still remembers how to service these? not just a quick look I am afraid, needs new diaphragm and check spindle, filters, and maybe water governor. not been serviced for a while by the looks of it. Isleworth TW7 area. Parking OK. Let me know if you can recommend...
  19. jaydebruyne

    service by Worcester Bosch

    Just been to look at a job for some plumbing bits and they mentioned their boiler, said it was just serviced by Worcester Bosch. 42cdi on 22mm pipework. The engineer mentioned they should change it but signed it off.. Really?????
  20. jaydebruyne

    Unvented cylinder annual service

    what exactly is done in an annual service for an invented cylinder? Other than checking no leaks, immersion elements are ok etc I have my G3 ticket. But don't be fooled, they don't teach you much on the course!!!