underfloor | Page 7

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

underfloor

  1. K

    Combi boiler flow temperature with underfloor heating

    hello, I have a Worcester greenstart 440 Cdi combi boiler feeding a wet underfloor to my whole house. There’s one manifold upstairs and onedownstairs. The underfloor manifolds have a trv to make sure the flow temperature remains at 40-50 (or even lessbecause I have a laminate floor). I have...
  2. SimonG

    Underfloor Heating Options.

    Been to look at a job this afternoon. Workshop being converted into a house. Current floor is 3" concrete on top of 3" of kingspan. Customers looking for best options. I was thinking of an overlay system to directly on top of concrete floor. Opinions?
  3. C

    Underfloor heating in new build ... does it comply with regulations?

    Hi ... I'm a keen DIYer who has installed a few systems in the past. My parents have just moved into a new flat and are finding the heating system very difficult to use. I am wondering if the below specification is sensible or even complies with the regulations ... It's a 2 bedroom flat (with 2...
  4. B

    Underfloor heating advice needed

    Hi all, I'm looking a bit of expert advice on an idea I have. We moved into a new house a few months ago which has its master bedroom over the garage. We used the bedroom for the first two months but have since changed because it was so cold. I've insulated the loft and sealed the garage...
  5. J

    Underfloor heating wet system-- Any Advice Welcome

    Hi I'm new here so take it easy with me. Empty Bungalow not moved in yet. Insulated cavity walls built onto foundation blocks with deep footings. Uninsulated concrete floor onto soil. I've done some research but finding it difficult to get unbiased advice. I am looking to install wet...
  6. D

    Underfloor heating - problems with thermostat

    Hi, I'm looking for some advice and hope somebody can help. I live in a new build house with underfloor heating on the lower floor and radiators on the top two. The bottom floor was controlled with a wall thermostat and the upper floor was controlled with a Salus room thermostat. I recently...
  7. S

    Heatmiser 4 zone system and underfloor heating control wanted

    hi. Looking for a Heatmiser Neoair thermostat 4 of them and UH8-RF fitted to exsiting heating system. Current wiring centre is a JGWWC and thermostats are managed by a salus RT500RF. Need finished system to be controlled by iOS devices. Current boiler is glow worm Ultracom. Please message me...
  8. V

    Water Underfloor heating not working - help needed to find the problem.

    Hi everyone and hank you in advance for your time. My kitchen water based underfloor is not heating up appart from a small area near the start of the laid pipe... The remaining of the floor is permanently cold as if there was something blocking the water flow. This appened only this winter (the...
  9. A

    Underfloor heating, 1 side not working.

    I have to look at a job tomorrow. The cust called and said that one side of the room works fine but the other side doesn't work at all. Reckons 1 half hasn't been connected up. Sounds a bit strange, I asked if it's always been like that and he said yes. Installed approx 1 yr ago. Also said he...
  10. M

    Underfloor Heating & towel rad

    Hi, I am having water underfloor heating installed in a one bed new build flat. I intend to have three zone. Kitchen/Lounge, Bedroom & Hall/Bathroom. My problem is that I want to install a heated towel rad in the bathroom. What is the best way to acheive this. I have a three port manifold. I...
  11. D

    Wet underfloor heating single room?

    ok so I'm putting in a wet underfloor heating system in my kitchen which is 3m x 6.5m, I will be running it off my baxi 105e combi boiler which is located in the room above the kitchen, we have already dug up the floor and will be putting a sub concrete base then 120mm of celotex insulation then...
  12. R

    Underfloor heating leak

    Hi there, I'm hoping for some advice. I had underfloor heating installed back in May for a garage conversion. Up until about a month ago, I'd not really used it as the room was warm enough. When I turned it on and set a program, I started to notice lumps in my laminate flooring. When I pulled...
  13. G

    Slim line underfloor hearing.

    I’m looking to install a slimline underfloor heating system over the top of my internal slab. I understand that it will raise the floor but I only have two internal doors to deal with. Anyone installed this type of system before? I’d like to know what the minimum scree I can use over it. What...
  14. L

    Underfloor heating query

    We have recently had a new unvented pressurised system put in our house to replace the old one. I'm trying to understand how our heating will now work to the underfloor heating part of the house. We have underfloor heating in the conservatory that seems to be controlled by a thermostat on a...
  15. M

    Wet Underfloor heating system not working

    Hi folks New to the forum so hello to all. I'm hoping someone can point me in the right direction. Our underfloor heating has not worked properly since we bought the house over a year ago now. We are getting limited hot spots on the floor close to the manifold but nothing much else. I don't...
  16. V

    Thermostat for combi boiler with radiators and underfloor heating

    I am planning to have a Worcester Bosch 34CDI Classic combination boiler installed soon. Most of the house will be heated with radiators except the kitchen which has underfloor heating. The new boiler will be installed in the kitchen where the underfloor heating is located. I already have the...
  17. N

    Fuse blowing on Altech/JG Speedfit underfloor heating system

    Hello, I have a wireless underfloor system controlled by altech receivers and transmitters. There is also a JG speedfit control board and distribution board. As soon as the transmitter connects to the receiver, a green light turns on and the actuator valves on a manifold attempt to turn on. As...
  18. N

    Underfloor Heating System

    Hi What underfloor heating systems do people recommend? I'm thinking of trying out the Buteline system for the job I'm doing at the moment. Thanks
  19. J

    Wet Underfloor Heating damaged pipe

    I managed to damage the outside of an underfloor heating pipe whilst chiseling the screed today. Im confident it wont leak (right away) but its certainly weakened. I have seen electricians use what I guess is some sort of resin when making joints that will be buried underground and wondered if...
  20. F

    Frost damage to underfloor heating pipes.

    This is on my self build project. 6 loops of 120M each were laid on insulation in 100mm concrete screed. The manifold was installed & pressure tested before the concrete was laid & held for a long time after. That was over two years ago & the building has had no heating in all this time. Just...