unvented cylinder | Page 5
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

unvented cylinder

  1. S

    Plastic pipes to/from unvented cylinder.

    Good afternoon, We are looking to buy a property but having looked in the loft I noticed that push fit has been used on most of the connections on the unvented cylinder. Mixed views so far on whether this is OK so looking for some advice on whether I need this inspected further before we...
  2. M

    How to isolate hot water from unvented cylinder to change tap

    Hello all, To start off I'm not g3 qualified. I have been reading around about unvented cylinders imploding in some situations when cold water to them is isolated and hot water tap is opened, often in an attempt to reduce the pressure in the system to carry out some repair on a hot water...
  3. T

    Unvented cylinder discharge pipe location

    I posted a year or so back about the total messed up install I had of an unvented system. I can finally get this resolved. I’m having the cylinder moved from the loft into the airing cupboard. At present the discharge pipe runs down the outside side of the house from the loft. Due to the move...
  4. J

    Changing unvented cylinder immersion element

    Hi all, I"ve got my G3 unvented. Customer wants an immersion element changing. Access is limited - once I get into the cupboard, and I do my electrical tests it hopefully might just be the stat that needs swapping. However, if it is the element... words of advice and tips would be...
  5. M

    System boiler fit to unvented cylinder

    My friends dad had a system boiler installed in replacment of an old floor standing boiler. The unvented cylinder is right next to the boiler. The firm has fitted the system boiler. But ignored the fact the pressure relief is dripping on the cylinder. As the expansion vessel has lost its charge...
  6. S

    Does anyone know this brand of Unvented Cylinder?

    Two different brands of Unvented Cylinder have been recommended to me. I have never heard of either of them, nor can I find reviews of them. Does anyone know them? Thanks for your advice. They both appear to have innovative internal expansion vessels, like the Mega-Flo's. Evocyl Air Standard...
  7. S

    What make of Direct Unvented Cylinder, and what size?

    Hi, some professional advice would be greatly appreciated, We are having an Unvented Cylinder installed into our 2 bedroom ground floor flat. I have had a few quotes and been given lots of differing advice, this always makes me wary, especially having suffered a history of poor quality work by...
  8. P

    Pricing to replace a vented cylinder with an unvented cylinder (megaflo)

    Hello , ive recently gone out on my own, i have been working in the industry 15years now /g3 qualified and i would just like to get some advice from the knowledgable people on this forum! i have done a lot of installing but haven't really got involved with the design as somebody else has done...
  9. Stants

    Unvented Cylinder size ? ( Evocyl )

    Hi all I'm having New heating set up installed in a loft conversion the Cylinder ( unvented ) and Boiler are being sited in a cupboard within the loft space ( adjacent to the new stairs ) im a bit tight on space Height and width as I am trying not encroach on the bedroom as much as is possible...
  10. Q

    Unvented cylinder install - safety concerns. Appreciate advise.

    Evening all, At risk of blabbing on i'll try keep this short. I recently replaced an old vented hot water system with a unvented system We went for the Telford Tempest 300L installed by G3 qualified person. Functionally it works well. Pressure is great, heats well, no leaks. There's still...
  11. H

    Unvented cylinder in celler

    If I install an unvented cylinder in a cellar and a system boiler on the ground floor above will the system still work?
  12. S

    Unvented Cylinder loses pressure when I bleed radiator

    my unvented cylinder system has been losing pressure. So I started the investigation as to whether it is losing pressure due to hot water or heating. So waiting for spring / summer when I don’t run heating much. I can see that only one of the radiators which I need to bleed as it is always cold...
  13. Lumen

    Unvented Cylinder. Does this guy know what’s he’s doing?

    Hey guys, Quick question for all you central heating experts out there. I’ve had a guy lowering two expansion vessels and installing additional zone valve for a new extension. As the result he’s re-done most of the plumbing in the airing cupboard. Nice guy, but he was rushing to get the job...
  14. C

    Leaking/Whining Unvented Cylinder

    Howdy, We had our loft tank removed and our cylinder replaced with a Worcester Greenstore unvented cylinder and have a few issues with it. Firstly, it is leaking pressure. We were advised it should stay around 1.2 bar when cold but have had to refill it semi-regularly. We cant find a leak on...
  15. M

    Temperature relief unvented cylinder

    What can be causing a temperature relief to drip. I have recharged the expansion vessle that had totally lost its charge. I am g3 registered. Thanks
  16. R

    unvented cylinder thermostat

    does any one know the difference between an ordinary immersion thermostat and one for an unvented cylinder, they look identical (both have overheat cut outs) but paperwork says not suitable for unvented cylinder, cannot get through to manafacture for advice, even one i got from online supplier...
  17. gmartine

    Unvented cylinder in loft - terminating tundish

    What would folks usually opt for easiest route to soil stack?
  18. M

    Unvented cylinder in loft with open vented heatinf

    I have a job putting an unvented cylinder in loft, (I’m G3) but they have open vented heating. I’m wondering if this will be possible as flow into cylinder will be higher than f and e tank. Worries about pumping over, any thoughts? Convert heating to close system first?
  19. M

    Combined feed and vent with unvented cylinder

    Got a job today to take out vented cylinder and replace with unvented indirect cylinder (i’m G3 qualified). Only problem is the system has a strange set up. It’s combined feed and vent S plan system. Heating zone valve is on the flow and pump and hot water zone valve on return. My issue is that...
  20. A

    Servicing Megaflo Unvented Cylinder - G3 Qualified

    Hi, I have recently had my Megaflo Unvented Cylinder serviced but didn’t check if the plumbing and heating engineer was G3 qualified before they carried out the work. I understand that it is a legal requirement to be G3 qualified to install an unvented system but is this also true to be able...
Back
Top