valves | Page 2
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

valves

  1. T

    Mixer taps and check valves

    Hello, I have a few mixer taps to install in bathrooms and kitchen. The kitchen tap also has a wondering spray arm capability. On researching something else, i stumbled across people saying that a check valve should be placed on the cold mains feed. How can I tell if the mixer taps/spray arm mix...
  2. oscarwplumbing

    Changing/fixing a bunch of seized imperial and metric valves

    Hi everyone, I'm new here! I've bought my first house - needs a fair bit of work doing to it, including the plumbing. I'm keen to do stuff myself rather than getting contractors in, wherever possible, not just for cost, but also because I want to learn (a useful life skill surely!) I'll...
  3. T

    What Isolation valves are best

    Hello, Is it ok to use a full bore isolation valve to isolate a hot and cold feed to taps or should I use a service restricted bore. I’m thinking about using a full bore with a handle as my default as I find that most of my customers struggle to muster up a screwdriver to isolate the water when...
  4. Naseemkhan1682

    Stop Valves for LDC 50mm Connection

    Hello, I received an offer from the Water Board for a LDC MDPE 50mm connection. We are currently laying the works required in our boundary. A stop valve is required for the external meter chamber but we are unsure which type to buy? There are many available online with substantially...
  5. A

    How can I turn down this traditional towel radiator with tap valves?

    I have recently had this radiator fitted and currently it gets very hot. I would like to turn the radiator temperature down however I'm unsure which valve I need to turn. I am not sure which is the flow or return. Or does it not make a difference? At the moment, both valves in the picture are...
  6. S

    Danfoss Lockshield valves leak after adjusting

    Heating system is 14 years old. On inspection I find that every lockshield valve is fully open. After adjusting some, I find that they weep slightly from the adjustment screw - valve type is as in attached picture, with only the adjustment screw behind the cap. Leak sealant is in the system - do...
  7. Hobo128

    Pumped shower valves

    Good morning all So been asked to install 2 power showers at a property recently... The property has a combi boiler which is only about 3 years old which customer doesn't want to change.... The only option I can see is an unvented cylinder and header tank. Can anyone else see any other...
  8. N

    Both Water and heating valves opening when either system called for

    Replaced the head of a Honeywell 2port valve on heating and wired into an old block (S) like for like. However, when either water OR heating called for, both valves open! Ideas?
  9. T

    Toilet Water Shut Off Valves Questions

    Hi, I was thinking about replacing the 3 x original Toilet Shut Off values as shown in the photo, in a property in Florida. They are not leaking and still work. I fixed some water weld around the wall cover to make them more rigid. Does anyone know if they are one piece? Or can the hose part be...
  10. G

    Overflow Bath filler and valves

    Hi, I'm really struggling to find out what part I need to use deck valves like this with a overflow bath filler. Most bath fillers seem to only have one connection. This one has 2, one for hot one for cold which looks like it could work. Anything I'm missing? thanks
  11. J

    UFH Thermostatic Mixing Valves

    Are there fundamental differences in some of these TMVs?. The attached one, below, would seem to be the better type where a shuttle moves to balance the hot&cold flows, as it increases one flow it decreases the other to keep the mixed flow constant, necessary say in showers etc. I have seen...
  12. S

    Are my myson power extra valves closing too quickly?

    Hi, we've been having a problem with our motorised valves. Every time the heating turns off there a number of loud bangs as if the water is hitting the valve too quickly which is then sending a shockwave through the pipes. Would this be faulty valves in that they are closing too quickly or is...
  13. N

    How to replace old 3/4 Radiator valves with 15mm TRV

    Hi There, I want to swap out my old valves for TRVs but the threads are different sizes, and I'm unsure how to resolve it. My current existing radiator valve setup is: The current valve has a 3/4" thread going to the radiator. I can't quite work out what's on the radiator side, but the...
  14. A

    Replacing bathroom radiator valves

    Trying to change bathroom radiator valves but I can’t get the old olive/nut off… any advice? Also the small plastic part next to the pipe, will I need to put that back in before fitting new valve? (Complete novice)
  15. R

    Cold Radiator - questions regarding valves

    Hi all, I'm hoping someone here can help. The radiators in my living room aren't heating as well as the radiator in bedroom, hall and bathroom in my flat. I've checked and both seem to be free from trapped air (tried to bleed and water came straight out). Now one radiator gets a lot warmer...
  16. S

    Low carbon steel pipes and rad valves

    Hi all hope all is well with everyone. Im a plumbing and heating engineer and I have worked only on domestic systems but am currently crossing over to commercial plumbing. I havent ever really done any steel pipework hence my question to you . . How or what is the procedure to changing a rad...
  17. Scott_D

    Isolation valves words words words

    What’s everyone using? General isolations valves for 15mm pipe to taps, toilets etc The £1 are crap The £5-6 levers are a bit overkill There doesn’t seems to be a middle ground valve
  18. M

    service valves or not

    Refurbishing a bathroom - cold water is mains fed, hot from combi. There is a main service valve to the whole system where the supply enters the house. Do I need to have service valves on bathroom sink, shower and bath? Normally if I have to repair/replace anything I just shut off the main valve.
  19. P

    Brass "Faringdon" lockshield valves leaking

    I have just tried to balance my heating system (16 cast iron rads, 3 towel rails), all the lockshields were fully open. When I try to close them down, they all leak, from a dribble to a gush. When I say all, I tried 6 and then stopped. The system was installed 9 years ago. Despite extensive...
  20. N

    bathroom isolation valves!?!?

    I’m trying to fit new pillar basin taps upstairs. Before I even got to that part I turned off the main stopcock under the kitchen sink but of course it didn’t turn off the water upstairs (who knew!?!) So I tried the isolation valves in the bathroom and only the hot one turns and the cold won’t...
Back
Top