  1. ShaunCorbs

    G3 diy (Gods not available locally)

    Wrong sorry just doesn’t need to be building control notified
  2. ShaunCorbs

    Hot water to multiple commercial kitchens

    It’s one of them you can’t do cheaply water mains isn’t upto the task so will need to be boosted first need an m and e designer and 100k
  3. ShaunCorbs

    Water pressure for block of flats

    So let’s take 2.6m to allow for dropped ceilings etc that gives you 10.4m need to pump so adds 1.04 bar ontop of your outlet pressure requirement so 4.04 bar required to give you 3 bar 4 floors up Working on the 70% rule that’s 50 flats needing water at the same time so that’s 1000lpm eg 20lpm...
  4. ShaunCorbs

    Water pressure for block of flats

    2.5 bar cold so let’s say 3 bar per flat and 20lpm how many floors ?
  5. ShaunCorbs

    Water pressure for block of flats

    Chances are the booster system isn’t designed for total load or is starting to fail eg pump seals etc
  6. ShaunCorbs

    G3 diy install who do It report to.

    Building control chances are he’s not qualified out of work hours etc
  7. ShaunCorbs

    Commercial or Domestic plumber required?

    Correct if manufacturers list the appliance as commercial then needs the commercial qualification hence why about 10 years ago a few manufacturers re listed a few models to large domestic because they were loosing sales
  8. ShaunCorbs

    Commercial or Domestic plumber required?

    Easy way to remember he’s ok on the boilers unless the manufacturer lists them as commercial but if you ever have to claim through his Insurance it’s invalidated He can’t touch the gas line due to out of scope Might be worth a chat to see if he’s willing to get the commercial qualification
  9. ShaunCorbs

    Hello all tradesman and DIY here

    Hello and welcome
  10. ShaunCorbs

    Can a DIYer replace an expansion vessel

    No the key does nothing but divert the water into the boiler The left white hex turns the water on or off to the filling loop Only if you leave the left white hex open / undone
  11. ShaunCorbs

    Can a DIYer replace an expansion vessel

    Correct once one bar or foot and no water is draining via drain tap Remove foot pump close drain tap and re pressurise boiler as you normally would do if pressure is low
  12. ShaunCorbs

    Can a DIYer replace an expansion vessel

    Keep draining while you pump up and wait until the water stops then pump some more until you have no water coming out and the shrader gauge says 1 bar
  13. ShaunCorbs

    Shower size help/advice (DIY)

    larger screen ideally the full length of the tray
  14. ShaunCorbs

    Bar shower mixer valve help (DIY)

    Tbh common issue and tbh you won’t notice it once you start using it etc
  15. ShaunCorbs

    Can a DIYer replace an expansion vessel

    As above sounds like it just needs recharging
  16. ShaunCorbs

    WHAT CAN I DO WITH THESE PIPES IN LOFT - Survey says DIY standard?!

    Tbh need a sheet of ply 18mm thick and that should do it turn the water off drain via hot water tap eg big tank will be nearly empty once water has stopped running Cut the 18mm ply 8” bigger than the tank all around and lift one edge of the tank and slide the 18mm ply under done the little one...
  17. ShaunCorbs

    Cast effect soil

    Anyone use silicon on strap on bosses I’ve got a cast effect stack to do and they a bit bumpy for my liking with glue
  18. ShaunCorbs

    Can't get a plumber - DIY advice

    That’s fine just use home runs (no joints other than manifold or rad) and mark each pair back to a central spot
  19. ShaunCorbs

    Is this a job for the pro’s or a job for a competent DIY guy.

    Measure and level the top brackets and hang the rad then mark the bottom ones once level and happy
  20. ShaunCorbs

    Hello - DIY homeowner

    ….. Hello and welcome …..