  1. D

    Back boiler not heating downstairs radiator multihead 3 pump

    Yes Replace the pump I would say the Pump was sticking that is why the service Guy gave it a Bang with a spanner . And upstairs was heating by gravity you had heating upstairs and hot water I would say . What some times can happens the impeller the part that circulates the water this can come...
  2. D

    Vertical radiator not heating up

    Some of those Verticals Rads Have the Flow and Return are on Different ends Try and find out the make of your Vertical Rad is get on to the manufactures they will tell you what way it has to be piped weather the flow is on the left or the return is on the right the manufactures will tell you...
  3. D

    Priority domestic hot water PDHW

    Take a look at the ideal vogue It has two relays For switching or use a w plan you can have both heating and hot water on at the same time but you can use a 3 way divirter valve This will get PHHW and when satisified It changes over to heating But use a Fast recovery cylinder as you well Know ...
  4. D

    Downstairs Bathroom - Sewage smell

    Just looking at your Photo The conection is not a patent joint You should use a Rubber Conection were it joins the red earthin ware Pipe to the PVC bend or another solution is to use what is Called a 6x4 tipple in Pvc Put the 6inch part over the earthinware pipe you have to calk the timple with...
  5. D

    Mains Cold Water Supply - Think I had a cowboy plumber at my house !

    Yes its Clowns like this that get Plumbers a bad name . Go to your local Plumbers Merchant and buy a 15mm stopcock the size of the water mains is either 15mm 0r 22mm but it can be reduced to 15mm under the kitchen sink to feed the cold water on the kitchen sink and possibly the cold mains water...
  6. D

    Milky hot water. Recently had a Viessmann 100-W combi boiler installed. Now when the hot water reaches any tap it is very 'milky'. This appears to be

    Most of the combi boilers that are installed in the UK there is a kit that most installers use like a heating filter and a water mains filter maybe and just maybe that the mains filter is faulty in some way maybe there is a break down in this mains water filter but you can substitute this filter...
  7. D

    Milky hot water. Recently had a Viessmann 100-W combi boiler installed. Now when the hot water reaches any tap it is very 'milky'. This appears to be

    If it's a vissmann combi boiler get in touch with vissmann they should be able to tell you unless there is a breach some were between the heating heat exchanger and the hot water heat exchanger it could and might be the additive that was added to the heating just a sujestion drain off some of...
  8. D

    Why do I have no hot water? Please help

    if you have a flexible pipe to the mixer set on your sink the pipe that connects to the flexible pipe on the sink could be kinked like bent over as a result this is how you have no hot water .if you have a hot connection at the washing machine this is probly blanked or knocked off take of the...
  9. D

    water help no hot water

    By looking at your question it sounds to me that the accuator on top of the 3way valve is giving trouble or faulty or your programmer is possibly faulty but if the boiler is fireing you should be able to turn on the valve manually to hot water but you can check all this if you have some...