Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

baxi

  1. G

    Baxi Neta Tec Problem + Pos Replacement

    Hello All, Firstly I am not in the central heating profession. We moved into a property 3 years ago and got lumped with this paper weight stuck to the wall in my loft. In the 3 years we've had it, the pcb was first replaced after error 133 code and not getting a flame. The whole manifold was...
  2. B

    Baxi fire front compatability

    I have a Baxi 552 back boiler,don't laugh but because it's been so good I want to keep as long as poss. My gas guy has told me i now need a replacement fire front so I am looking out for one.As I understand there are two fronts for this boiler one with ceramic radiants which is mine and one with...
  3. A

    Baxi Duo Tec Keeps Dropping Pressure

    Hi, I have a baxi duo tec 28 HE which keeps dropping pressure and return E119 error code. In the last month it's had to be topped up 3 times and I topped up again early this week to 2 bar and today the pressure has dropped to below 1 bar. I've checked all the radiator valves for leaks but...
  4. Jimmy18

    Baxi 105 he breakdown

    hey guys, Had a call out today to a baxi combi that’s one of my dads friends. Got there and no heating or hot water. So took off the case and checked a few bits. Pump not running so checked power from pcb. 230v checked power at pump, nothing. Also when my ears pricked up a bit is when I looked...
  5. Scott_D

    Baxi Duo tec 28 service

    Got one one these to service next week but I dont see many Its 5 years old and still under warranty Is it recommended to replace the burner door seal? Anything else that should be replaced eg electrodes?
  6. R

    BAXI DUOTEC COMBI 24 HE A. Diverter issue. Motor, Sensor or Valve

    Hello all I have a BAXI DUOTEC COMBI 24 HE A. I suspect a diverter issue. Symptoms are hot water but cold rads. No fault codes to report. At least nothing that begins with the letter "E". No fuse issues. There is a CENTER wifi stat involved but I am satisfied that's functioing ok. Been...
  7. M

    Help with a Baxi Solo 30 HE Regular

    Hi All, This is my first ever post as a newly registered gas safe engineer. I’m looking for help on an issue I tried to help with for an old couple that live locally to me. They have the above boiler and very recently have had constant issues with it kettling and almost immediately locking...
  8. Steve weightman

    Baxi solo explosive ignition

    Visited a baxi solo 24he with explosive ignition so looking for spark electrode issue or gas valve issue or even inlet pressure but all looking ok. One thing I noticed was the programmer is faulty flicking on and off . Just a thought but would you think this could be the issue partially...
  9. C

    Baxi Megaflo Vs Baxi Ecoblue?

    Hi Guys, Making a choice between buying Baxi Megaflow 32KW System or Baxi EcoBlue 32KW System. Will be supplying Megaflo 210L cylinder. Baxi themselves don't seem to be able to give any answer on the differences other than one has an LCD screen, the other is just LED screen with turn knobs...
  10. S

    Baxi Combi 105 HE drips water

    Hey, I've got a Baxi Combi 105 HE, and there's a component at the bottom that drips water. Not a lot, I'd say 1 drop every 10 sec, but annoying though. Here's a screenshot from the manual with the part I mean: Is this something I can fix myself? I can do basic plumbing and central heating DIY...
  11. H

    Baxi combi zoned is additional bypass needed?

    Hi, Just installed U/F heating in my extension so put S plan in with 2 valves on the return. When the valves close the boiler carries on for a little while (orange connected to boiler heat demand). The manual says 'The boiler utilises the primary side of the DHW plate heat exchanger as an...
  12. G

    Baxi BBU with Bermuda fire front.

    Hi, I have a Baxi BBU AND Bermuda fire front. Both are in perfect working order and we’re not looking to have a combi installed anytime soon. Are there any fire fronts that are compatible, if we wanted to change it? Fire works perfectly. But it’s ugly! I have seen an SP3 on Ebay, but not...
  13. G

    Baxi Duo Tec 2 GA problems

    Hi guys, do any of you know when Baxi discontinued theDuo Tec 2 GA? I have had a long litany of faults since it was installed in 2012.
  14. F

    Daily lockout on Baxi boiler.. aargh!

    I had a engineer round my place last week to service my Baxi 100 HE Plus boiler as every single day I'm having to press the lockout button to get the heating to come on. He gave it a clean, increased the pressure and told me it should all be ok. But it isn't! The problem is still ocurring and...