baxi | Page 2

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

baxi

  1. P

    Baxi 105e dhw strange

    Hope someone can offer some help with this issue, I have a Baxi 105e works fine no real downside, serviced looked after regularly. Have an issue with hot water, open hot water taps runs cold and indicates on boiler 60degrees or pump or pressure problem. Leave it ten seconds open taps again low...
  2. A

    Baxi boiler - heat exchanger

    I have a Baxi Duo Tech 28 HE. According to an online search with the serial number and GC number, I should have a 20-plate heat exchanger. So, I purchased a 20-plate unit. However, when I removed the old part, it appears to have 12-14 plates. Is there any harm in installing a 20-plate exchanger...
  3. J

    My boiler (label of Baxi) sent a 'low water pressure' warning 0.8 bar

    Hi all, My boiler is Remeha avanta ace 28c - Avanta Ace - The Feeling of Warmth - Remeha - https://www.remeha.nl/product/avanta-ace It's 1 year old, and since I'm away for a few weeks I set it to 'frost protection' mode. This morning I woke up to a 'low water pressure' warning 0.8 bar, and since...
  4. G

    Baxi 105e CH loud screeching/whining

    Hi, around 3 week following a diverter overhaul with a valve and seal kit (due to leak between diverter housing and diff housing) the noise started to occur within a few minutes of activating CH. I'm pretty sure the noise is coming from the diverter and it is carried along pipework in walls and...
  5. G

    Baxi 105e screeching/whining

    Hi, about 3 weeks after overhauling the diverter and diff valves with valve and seal kit, the noise started to occur seemingly from the diverter although it's difficult to pinpoint exactly. The noise starts a few minutes after CH is activated, and is persistently loud and is carried through...
  6. K

    Older Baxi Solo condensing boiler - optimum temperature setting?

    I have an older Baxi Solo 18 HE condensing boiler which is working fine. It’s very basic with a boiler temperature control. The boiler temperature control knob is very basic setting displaying low to high, turn clockwise to increase, anti clockwise to decrease temperature. What is the optimum...
  7. P

    E133 Baxi Megaflo System - But works fine in High Rate Mode!!

    As per the title. We have a property where the boiler has worked fine in the 10 months since it’s last service. Now throws up this error code randomly, and doesn’t reset. Our man has checked all the usual culprits. Condensate is fine, not backing up. He can put the boiler in High Rate mode and...
  8. PlasmaMan13

    Baxi Solo 3 Pilot Light Always On

    Hi Guys, Got a problem with a Baxi Solo 3 PFL50 The "pilot on" light is on permanently It was intermittent, but is now permanent When this happened, the boiler would not go through the normal start-up sequence Turn on the control and the 'boiler on' light comes on, but goes no further I...
  9. G

    Baxi Duo Tec 28 Hot Water Issue

    Baxi Duo Tec 28 Hot Water Issue. Hi, I have a Nazi duo tec 28. I’m having an issue with my hot water. If the CH is on, and I turn on the hot water I get warm/tepid water provided the HW temperature dial is set about 3o’clock. If it’s set any higher, I get an E28 fault, and my water goes cold...
  10. John Donnelly

    Baxi Megaflo no display

    I noticed a few weeks ago that my hot water and heating were not working so I went to check the boiler expecting to see an error code, but on checking, the display was completely off. I could hear the fan running (quite loudly) so I knew there was power going to the boiler. I opened up the...
  11. M

    Baxi Boiler - Water Not Getting Hot 1st thing in morning

    Our Baxi boiler works fine most of the time but the last few days it does not heat the water first thing in the morning and occasionally later on in the day too. It still works most of the time, e.g. for baths. The pressure is fine even when the water isn't heating. I've had a look online and...
  12. L

    Baxi Platinum Boiler Error E1 33

    Hi Guys, I have installed a boiler "Baxi Platinum+ 40Kw Combi" on the outer wall in the loft. It works fine for 1 or 2 days and then it gives E1 33 error randomly. It is connected to the Hive Thermostat too. I have checked all the common reasons for getting this error but in no way could...
  13. E

    Baxi System Boiler Weather Compensation

    I'm wanting to install weather comp on my Baxi Platinum+ system boiler (GC No: 41-470-95). This is because the house is heated using underfloor heating which is mixing down to 35c but the boiler is set to 70c to heat the unvented cylinder up to 60-65c. The idea is to select a curve more suited...
  14. R

    Baxi 228 combi boiler hot water flow rate poor?

    Hi, Just checking I'm not talking rot. Today I visited a house with a Baxi 228 combi boiler. The technical spec for the DHW output is shown in the image. Boiler was installed 27 months ago. Baxi is claiming 13.3 litres @ DT 30. I set the boiler DHW temperature to a high setting. I was...
  15. S

    Baxi Combi 105e: CH lost 1 bar of pressure in a few hours

    Hi everyone Summary is in the title. Found the boiler was at 0.5 bar earlier today so topped up to 1.5 bar. Checked before bed and its back to 0.5 bar. There are no signs of a leak around any radiators nor any suspicious water damage on the downstairs ceiling. Before I rip up all the flooring...
  16. P

    Is a Main boiler a Baxi? Yes or no

    So, we were quoted for a Baxi boiler by a local boiler man. He came out and installed a Main. He said it's a Baxi. It's not what we were quoted and he's saying that they're Baxi. I understand they're part of Baxi but they're not actually Baxi boilers right!? He also told us he needed to sort all...
  17. P

    URGENT Baxi Duo-Tec Combi 33 HE DHW Fault

    Hello, Looking for someone who can please help solve this problem and fix our boiler. Staffs area. CH seems fine. Boiler can be coaxed into full burn with the fan spinning at full speed, so I think everythings fine on the gas/air/flue/condensate side of things. If there is DHW demand on the...
  18. J

    Baxi 830 radiator pipes connected wrong way round on boiler

    Baxi 830 plumbed in correctly Hi all I have a new baxi830 4 months old. Noticed the other day that the central heating flow and return pipes too and from My rads are connected to the incorrect boiler couplings. Eg the radiator flow pipe is connected to the radiator flow return connection on...
  19. N

    Baxi 600 without opentherm

    I've got a Baxi 600 combi, with a Google Nest thermostat, fitted a year ago. I've just learnt about OpenTherm, so went into my Nest settings, and found that it is disabled (only on/off mode is selectable, OpenTherm gives an error message). I spoke to the installer who says that he never...
  20. Gilbbb92

    Baxi 630i Error E133 Urgent Help

    Good afternoon Guy's & Girl's, So I have a Baxi 630i that is showing a e133 fault. Upon hours of extensive research it is an ignition fault that can be caused by numerous of issues. One being that the condensate pipe is frozen, given the current weather and climate I edged my bets on this...
Back
Top