Hi all I have an old Baxi solo 2 40 boiler. the other night that there was a metal sounding twang and the pilot light went out now the boiler will not work.
You can light the pilot and that stays lit, but as soon as a load is asked of it it fires up for about 30 seconds and then it just cuts...
Hello
Does anyone know if its possible to connect an Opentherm thermostat such as a Nest to a Baxi 800 System boiler.
I know its possible with a Baxi 800 Combi but I cannot find any information on achieving this with a system boiler.
I wondered if its possible to control the radiator flow...
Hi
I've come back from a two week holiday to find my Baxi boiler displaying an error. It's a Baxi Ecoblue Advance 19 Heat ERP and the error is a red light flashing 6 times. This seems to mean "Miscellaneous" in terms of error codes. A reset is doing nothing.
I've had a plumber out who's...
Hello all
My BAXI boiler suddenly turned off, it has a small screen that is now completely blackout, i have tried switching it off and back on but it doesn't do anything. When the switch is switched on, I can hear the boiler fan noise going but the screen still doesn't show anything.
Here are...
Hi
I have a BAXI NETA-TEC COMBI 33 GA boiler and every morning I come down to a small puddle of water underneath the boiler. The gas engineer has replaced two washers in the DHW and a new baxi brass adapter and tightens all connections, still the leak remains.
It does not leak when the hot...
Got a customer with no hot water or heating topped pressure up and was fine on hot water. Put it on heating and pressure goes from 1.2 bar to 2.8 bar in no time at all. I’ve heard about faulty expansion vessels with these. Any ideas? I’m fairly new gas safe engineer and mainly do installs. Any...
Got a customer with no hot water or heating topped pressure up and was fine on hot water. Put it on heating and pressure goes from 1.2 bar to 2.8 bar in no time at all. I’ve heard about faulty expansion vessels with these. Any ideas? I’m fairly new gas safe engineer and mainly do installs. Any...
need a new c/h pump.we have a baxi bermuda back boiler which serves 6 radiators would a wilo 25/1-5-130 or 25/1-6-130 i read that with this system i wouldnt need an all singing and dancing pump . advice required ?
I have a Baxi 100 HE boiler and it's been good over the 20+ year lifetime. But it's at the point where it requires major parts.
I'd like to replace it with something similar. I'm thinking that a boiler from the same manufacture might have connections in the same place (easier for the engineer to...
I have a Baxi 100 HE boiler and it's been good over the 20+ year lifetime.
I'd like to replace it with something similar. I'm thinking that a boiler form the same manufacture might have connections in the same place (easier for the engineer to fit a replacement).
Question: Are some ranges of...
Looking to connect a Tado extension kit and smart thermostat to a Potterton Performa 30 HE boiler. Is this boiler OpenTherm compatible, or does it have some other eBUS for digital control? I can find absolutely nothing online and the the installation manual does not mention digital control. If...
Hi all. Can anyone shed some light on this fault please. Boiler is cycling when system is hot.
It's a 40kw combi ~ 8 years old. we have 10 rads on the system. 1 towel rail isn't currently working in the bathroom maybe an airlock? Have previously had an airlock on one of the rads downstairs...
Hi all
I’m having a problem with my Baxi combi boiler and wondering if anyone is able to help. In short, the water isn't heating.
A few months ago (c.2 months) my Baxi combi boiler had an issue where the hot water would go hot and cold on a regular cycle; it would get hot, then cool down, then...
Hi
After some advice if poss, my boiler is dripping water and it seems to be coming from behind the heat exchange, is there anything behind that could be the cause or is it the heat exchanger ? If it is the HE should I get it repaired or would I be better getting a new boiler ? And if I get a...
Not doing so much work these days but came across a platinum where the boiler heating stat was on full.
Yet I noticed on max the boiler stat was only reading 30 on full . Owner had thought it wasn't getting that hot at the rads. I always recalled the boiler stat could be turned on max and red...
Does anyone know if there's an engineers level and parameters on the Baxi 600/800 range, including the Main Eco Compacts? Can't find anything online.
Most manufactures allow you to set minimum pump speed etc, and adjust heat outputs and a few other bits. There's nothing in the manufactures...
Old client reported this issue before moving house. New owner has contacted me since for same.
Boiler set to come on with timeclock. They notice the house is cold, check boiler and it's displaying OFF in fire-front display in side. Reset boiler afaik (else press on/off) and away it goes until...
Hi, I just wanted to ask if the receiver of a wireless thermostat would use the current wiring I have to a external programmer? I have a Baxi platinum 28 boiler.
My baxi boiler keeps showing error code E133 we reset it and it comes back on; this only seems to happen late afternoon early evening, it can happen a few times in one evening then not again for a few days later sometimes a week later, I’ve been told it’s low gas pressure but when I googled it I...
I have bought a WISER Kit 1 to control my BAXI Platinum HE Combi boiler
The boiler is currently controlled by a wireless thermostat and timer. The sender unit is circular and sits in the front bottom right of the boiler looking at the boiler from the front.
The WISER apparently needs a...