baxi | Page 6

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

baxi

  1. K

    Bolier turning on and off constanly - Baxi

    Hi all My 4yr old baxi boiler turns on and once it's reached the thermostat temperature it starts to turn on and off every 5 secs. The pilot light turns off and then you hear it fire up, turn off, fire up, turn off. This continues until I turn it off and let it cool down. It has a separate...
  2. R

    "Main" (Baxi) 24HE A Heat only boiler temperature setting

    Hi. Bored and wondering about a friend's boiler that was fitted a few years ago and that, having been involved with the heating system, I take an interest in. One of these jewels...
  3. T

    Baxi main Ecco 25 combi boiler bypass pipe 5114715 is leaking from both ends one end is fitted to the 3 way valve assy

    Baxi main Ecco 25 combi boiler the bypass pipe 5114715 is leaking from both ends one end fits into the the 3 way valve assy
  4. A

    Help diagnosing baxi duo-tec 40

    I am working on a baxi duo-tec 40 boiler there is no heating and hot water running fine. I've checked diverter valve and both motor and pin are operational. This boiler is just over 4 yr old only serviced once before though. Next i want to check temperature sensor for central heating as they...
  5. C

    Replacement of Baxi Bermuda C5 fire

    Hi there I have a Baxi Bermuda C5 fire with back boiler and want to replace the gas fire only with a more modern one but leave the back boiler in place, what are my options please? Regards
  6. P

    How to replace a Baxi 105E microswitch?

    Hi Looking to replace the Baxi 105E microswitch but Worried about getting the white connectors off without damaging the wiring. has anyone done it and if so is there a trick to getting the connectors off?
  7. K

    What baxi coal effect firefront can i use to replace a baxi 552 firefronts.

    What coal effect firefront can I use to replace a baxi 552 firefront.
  8. P

    BAXI 105E Error 60 light

    Hi, have changed the DHW diaphragm as wasn’t getting hot water to shower, the old one did have a tear. Now getting error 60 light every 5 or 6 times the boiler fires up. Could this have anything to do with the change I made? many help much appreciated 😀
  9. C

    Baxi Platinum 33 HE Losing Pressure Having To Top Up

    Hi everyone and I hope someone can help. Five years ago I had a new central heating system installed with a Baxi Platinum 33 HE in a 10 year warranty. It is service by a Baxi Engineer every September and I never have to touch it. Anyway, I had a new wet room installed in my small bathroom and...
  10. K

    Baxi, spying on engineers.

    Halfway through changing a hydraulic block on a greenstar 28i junior I got a call from the baxi rep. That can't be a coincidence!...? Bit late now but how are you supposed to get the clip back on that flow sensor assembly 🤬 I grind the clip tips down to a flat and work in with grips but I know...
  11. G

    Veissman 050-w vs Baxi 600 624 24kw

    I need to choose a reliable budjet boiler. Ive never installed a veissman before and its been years since i installed a baxi. I like the specs on both boilers. The amount of plastic and rubber worries me about the veissman but i do still like it, the baxi 624 looks like a lot of boiler for the...
  12. S

    Baxi Platinum 28HE - Condensate problem

    Hi, Noob here Struggling with a Baxi Platinum 28HE. a few years ago, the boiler was (almost) completely rebuilt with about 99% new parts. but today, it stopped working with an E133 fault code. I checked the Condensate pipe and it wasnt blocked. I took the front panel off the boiler and it...
  13. J

    Baxi Solo 30 HE ie

    Baxi Solo 30 he, existing boiler in newly bought house for client. Condense trap replaced and combustion chamber door seal replaced. 1" bsp nut missing from trap to discharge pipe connection. The house is split levelled with 17 radiators, pipe sizing is off. There was a 6m head pump on return...
  14. S

    BAxi duo tec he 24 - water only luke warm

    Hi. Hoping you can help. I attempted to top up the pressure but turned the wrong levers. My hot water is now only Luke warm. If I turn the tap on less the half the water gets hot. This is no good for having a shower. Please can you tell Me how to solve this? I have insurance but they can’t come...
  15. W

    BAXI boiler explosive ignition and...

    Hello everyone, I've got a few issues with my boiler. It's BAXI platinum 24 combi. 1. Occasionally when it fires up it does it with a big loud bang (explosive ignition?) From what I've noticed it usually happens when central heating starts up, doesn't happen with hot water (or it's just...
  16. R

    baxi 105he no heating

    hi to anyone that can help the above boiler has been fine until Friday last week when the ch stopped working the boiler fires up then after a min it shuts down the heating light is on and the temperature lights are on to max but no heating, run some cleaner through for a week and it came out...
  17. Hobo128

    Baxi combi 80e dhw issue

    Called out to this boiler last night.... No hot water... Heating fine... Run the hot tap, boiler does not fire.... Pin on diverter does not operate.... if I manually press micro switch boiler fires.... I am going to replace the diaphragm in the diverter valve tomorrow... However! I have...
  18. P

    Baxi Bermuda - Older Person Needed... (Possibly!)

    Hi Ladies and Gents, I've got the worst kind of problem.... An intermittent one.... So, Baxi Bermuda 45/3E back boiler, S plan system. It's serviced, in great nick and the system normally works perfectly.... Here comes the BUT; The issue is that it occasionally fails to come on, despite one...
  19. A

    BAXI Solo HE

    Hello, We have recently moved into a new home that has a BAXI Solo HE (IE) Condensing Boiler. It appears to be reasonably new as does the tank and pump. (< 4 years) We have no issues with it so far. Plenty of hot water and central heating is fine. We have been advised to replace with a combi...
  20. J

    BAXI Combi Instant 105e pressure

    Can anyone give me clear instructions for repressurising / topping up a BAXI Combi Instant 105e? Please see attached photo. Levers should be at top in case it appears rotated. It's not my boiler so am unsure. Thanks!
Back