    Baxi solo Noisy boiler

    Hi all, i have a Baxi solo boiler which is making awful noise. I have checked and double checked and it's not the pump or the flue fan, the noise is like a noisy pump and also a banging noise, it only happens after the boiler has been running for about 30 minutes and the moment the burner stops...
  2. M

    Baxi combi 80d to potterton titanium

    Hi all I want to change my son's Baxi combi 80e to a potterton titanium I think the back mounting plates are the same but the potterton has an offset flue Baxi seem to make an offset flue adaptor and was wondering if anyone as done this change the Baxi is 15 years old and been relatively fault...
  3. phil hair

    baxi solo 15he ignition lockout

    hi, been to a baxi solo 15 he with ignition lockout fault. seems to run though the ignition cycle, can hear the gas valve open but not sparke. It fired briefly when i disconnected the earth from condensate, but went out immediately. condensates dry, changed the sparker because of continuity...
  4. stings27

    Hot water problems Baxi duo -tec

    Hi all. Got a call from my brother in law this morning regarding a problem with his Duo-tec. When he opens the HW tap on his sink unit , the boiler will not fire but he reckons ( I have not visited due to the current situation) when he opens the taps upstairs in bathroom it does ??? Says...
  5. S

    Baxi 80e continuously cycling on and off on heat

    I have a Baxi 80e, old, but works well and I'm told easy to work on and spares available at a reasonable price, so not keen to put in a new one just for the sake of it. At the beginning of April, it developed a fault on the heating side (hot water is fine). It lights (when heat is requested by...
  6. G

    Baxi Genesis 80 combi

    Dear Group I have a baxi genesis 80 in my office. Upon turning the boiler on, the pump runs continually and the flame immediately fires up when in the water only mode even though there are no taps on. The flame stays on for perhaps 20 seconds whereby it sounds like its boiling which it...
  7. J murton

    Baxi boiler service tonbridge

    Hi I’m looking for someone to fully service my baxi combi boiler. It’s an old model and needs a proper service. Can anyone recommend a good engineer in the TN area. Thanks
  8. G

    Baxi duotec 28 HE A- no heating

    Hi guys, hopefully somebody can help because I'm at my wits end here. I have a Baxi duotec 28 HE A with no heating but hot water is fine. There are no visible leaks in or outside the boiler and it has been regularly serviced.The honeywell stat and relay module have been replaced, but still no...
  9. G

    Error 385 on Baxi Megaflow 2 GA compact

    Hi, I am getting error code 385 on my boiler display which online states 'low voltage'. Any idea on what I can try? Someone suggested replacing the fuse but no idea where to locate it, can anyone help? Thanks
  10. Harvest Fields

    Baxi 45/4m back boiler unit

    Morning all, any help would be appreciated. Been to a job (first service) where someone has used rock wool to seal the flue inside the builders opening. Anyone got a part number for the sealing/ceiling plate need to seal it correctly?
  11. Scott_D

    Can you ID this Baxi?

    Surveyed for a combi conversion and forgot to look at the make of Baxi boiler to be replaced. Can you ID from the picture?
  12. D

    Baxi 105e problems!!!!!!!

    Good Evening all, I have a Baxi 105e. 17 yrs old. Few problems if any one can help. 1, The guage on the front of the boiler sits at '0' but when the heating gets up to temperature it sits at 1 to 2 bar. Why is the boiler still firing up when the guage reads 0?? 2, When I run the hot...
  13. stings27

    Baxi VP ignition problem

    Hi all. Went to a customers house last week because they couldn’t light their gas fire. Initially I thought it was the spark generator but on closer inspection the problem looks more to do with the control assembly. If I press in the control knob gently but not fully ,it will spark& sometimes...
  14. S

    baxi duo-tec2 fault code e385

    as above driving me insane about ten people from 27/4 rescue looked at it can not find problem,i get hot and ch but it takes a while for it to come through all the time flashing 385 then all of a suden will fire up and be fine
  15. P

    Leaking flow pipe on Baxi 105e

    Hi, I've got a leaking flow pipe coming from the main heat exchanger. There is slow drip where it connects onto the main heat exchanger. Before I take it all apart could someone tell me if it's better to replace the whole flow pipe or can I just change the seal on it?. Kind regards, Joshua...
  16. M

    Baxi Duo Tec 40 HE A Fluctuating Hot Water Temperature

    Hello All, I am currently having an issue with my Baxi Duo Tec 40 HE A not maintaining a constant temperature for the domestic hot water. With a thermometer under a tap & the domestic hot water thermostat set to 43 °C I get a fluctuating temperature from 51 °C to 38 °C which is clearly not...
  17. D

    Old Baxi Bermuda Back Boiler with Elson? Square tank in the Loft

    I have one of these in my loft but no manual so I can understand how it operates (eg is the water temp thermostatically controlled?) etc. Can anyone point me to a link where I can download a manual? Thanks
  18. S

    URGENT Baxi 105 he fluctuating hot water

    Help required Baxi 105he. Boiler is 10 years old and has been a pain for a while now. Ch workes great no issues. Hot water however not so good. I need to turn the tap on quite fast to get the boiler to fire up. Once fired up because the water flow is so high it’s not very warm. I can slowly...
  19. H

    Replacement glass for Baxi Bermuda RG3

    Hello, I've been checking ebay etc for ages and know that the model is obsolete but does anyone know where I might have luck getting replacement glass? (See attached) Thanks HH
  20. J

    How to repressurize my Baxi boiler?

    Hello, I have a problem with my Baxi boiler. Error message 118. Pressure: 0. The instruction says I should repressurize it. Could you please explain me how to do it? Attached you can find photos of the boiler. Just to let you know I am blonde, so please step by step instructions ;) (I...