gas fire | Page 8

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

gas fire

  1. A

    Pilot on gas fire will not come on

    Hello out there wonder if anyone could tell me why the pilot light on my gas fire will not allow any gas through?
  2. P

    Please help, I can't find the data plate on my gas fire and don't know the make!

    I am having some cavity wall and loft insulation fitted just after Xmas by British gas but before they start work they need to see the manufacturers instructions for my gas fire, I have looked for the data plate but can't find it, could it be on the back of the fire? Any help would be very much...
  3. O

    gas fire regs gather hood/closure plate?

    Hi, we are installing gas fires on a job, there are existing 7" chimney liners coming from the masonry "ceiling" of the fireplaces, what are regs regarding the connection of the new flue to the existing chimney liners? Is it corgi or building inspector's governance? I've consulted a few...
  4. Z

    Anyone heard of this gas fire

    hoover highlight b575
  5. C

    New World Merlin Gas Fire Model 017079 Manual required

    I need to find out what the ventilation requirements are for a New World Merlin (017079) 6.3kw living flame gas fire. The client thinks they purchased it from B&Q some years ago but do not have a copy of the manual. Anyone out there with a copy that could confirm the ventilation requirements...
  6. B

    Fanned gas fire goes out after 10 minutes

    I realise there's another recent post on here about a gas fire going out after a while, but I had the same problem when servicing a fanned flue fire the other day. I was told about the problem before I touched the fire. The fire lights and stays on for about 10 minutes then reduces to low flame...
  7. D

    Gas Fire Starts then stops?

    Hi Guys, just had a call from a customer phone and they have said that there gas fire stays ignited for a few minutes then goes out? I dont usually get involved with gas fires but i am qualified for gas fires. Do you think its probably the thermo couple? Are there any other common problems...
  8. D

    Gas fire works then stops?

    Hi Guys, just had a call from a customer phone and they have said that there gas fire stays ignited for a few minutes then goes out? I dont usually get involved with gas fires but i am qualified for gas fires. Do you think its probably the thermo couple? Are there any other common problems with...
  9. F

    Kinder Oasis gas fire problem

    Hello again Got called to service a gas fire yesterday, was getting dark so decided to bump it on to this mornings jobs. While discussing the history of the appliance with the customer she reported that over the years the performance of the flame in and around the coals had began to wain and...
  10. L

    gas fire

    Cannon Caress gas fire cuts out after about 20mins.The flue has passed and spillage passed.I have replaced the pilot shield as this was twisted metal and the 5 moulded coals are new.I have serviced the fire everything seems ok but cuts out after 20 mins.Any help would be welcome.
  11. K

    Gas fire 5.4 kw without a flue liner

    Hi everyone im working on a house where they need to take the chimney down due to a new roof required. However they want to keep the gas fire is there any way round it.
  12. P

    A 'Sometimes' Homeflame Harmony Gas Fire

    Sometimes it works and sometimes it don't! My 5 year old gas fire (serviced every year) has suddenly started to act up. Using the sliding lever at the top, moving it all the way down it fires up the gas - never fails to fire up the gas. However, after counting the recommended 10 seconds and...
  13. F

    Gas Fire

    Thanks alot
  14. S

    Bermuda vp gas fire

    Going to look at an old Bermuda vp gas fire and was after advice before visiting. Ignites ok but will not go onto higher flame settings. Was working ok 6 months when I replaced thermocouple and electro magnet. It is the earlier model without oxy-pilot. Just ignites over burner. If I check gas...
  15. D

    High Co on gas fire

    Hi Guys, I went to service an LPG gas stove today. I carried out the service to the manufacturers instruction and everything was fine. I put my FGA in the flue outside and the ratio was fine. When i tried to turn off the FGA it wouldnt and kept saying "High Co" the co% was 7.6. The flame picture...
  16. T

    How much do you guys charge to fit a gas fire?

    Hi guys, been to a property today where a previous GSR has capped off the fire. The landlord wants a new inset fire fitting so I've been, taken out the old fire and inspected the chimney, which is lined and passed the flue flow test. I don't do many fires and as a result i think it will...
  17. H

    Gas Fire

    Hey, I have a gas fire , make unknown but seems to be of good quality, it was here when I moved here and did work fine. You need to press button to start up fan and the button lights up red, when the red light goes out you can then light the pilot light by pushing in another button. Well, the...
  18. A

    New World Merlin MF 017079 Gas Fire - Manual Needed!

    Hi, New World Merlin MF 017079. I have this gas fire, but a gas engineer told me not to use it as I don't have the instruction manual that shows how the ceramic coals should be arranged. Correct arrangement is needed, to avoid faulty combustion & CO. I've looked online to no avail; the...
  19. D

    outset gas fire

    i 've taken a back boiler out connected to a pre fabricated flue,the connection from the bbu hood was selkirk twin wall ,this part fell away when i pulled the back boiler out,what is the best way to make good,with an out set ,closure plate etc,the builders opening is huge.
  20. N

    Co ratio gas fire

    Have been doing some servicing and safety checks for a HA over the last few weeks, mainly boilers and cookers so all good. Had one yesterday with a gas fire and didn't think anything of it until the system we use asked for a flue analysis and then i realised I've never used a FGA on a gas fire...