Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

glowworm

  1. S

    strange fault on glowworm

    Mainly posting this to help someone out incase they come across this fault. Anyone want to take a guess on this one: f22 coming up would not go through ignition sequence just constant f22. (Overheat). Checked resistance on thermistors, o/h stat for continuity, cleaned condense trap. All okay...
  2. I

    Glowworm fuel saver 30b.

    Anyone got a link to the mi's? ta
  3. T

    Glowworm ultimate 30c. Pressure relief connection

    Hi anyone had any issue with these ? Got called out last week to 30c. Boiler, water coming out where the re lief pipe was screwed into boiler, the tenants had Over pressurised the system (it,s a plastic thread ), I put the boiler in a few months back and found it to be a little awkward but...
  4. B

    one for the older guys glowworm spacesaver 50 mark 2 wall mounted open flue boiler

    went to this boiler today it has a kitchen cupboard around it but has more than the req clearances 105mm at sides 600mm from top to ceiling 600mm from bottom of boiler to worktop .100mm from front to door . cupboard vented 200cm2 at top and 600cm2 at bottom. room vent 100cm2 .the issue I have is...
  5. B

    Glowworm 30 cxi no ch

    Called out to this, no display, absolutely nothing. Replaced pcb and user interface. Got display F9 showing. Fitted wter pressure sensor and filling loop. Hot water fine. No ch. Any ideas / solutions.
  6. B

    glowworm hxi

    had look at this last night the hxi with orange display . boiler fine in max rate but in low rate it screams like a jet engine.tried the off set but no joy it sent analyser bleeping.spoke to glowworm who said poss gas valve - but i thought gas valve just opens and fan pulls the amount of gas...
  7. B

    glowworm ci

    not looking forward to this one - ordered diverter service kit - last one I did was not to bad(apart from lining up both sides of the diverter assy pin one side bush the other) but this has very poor access not sure if I will be able to remove side panels.as very little clearance.
  8. B

    Glowworm ultimate - front casing feels too hot

    Hi guys, any reason why the front casing on a glowworm ultimate Would get too hot? i serviced this boiler a found everything to be ok but one it was back together and heating up, the front case feels a little too hot for my liking. It's not 'ouch yer f*ucker' but it defo hot by the way...
  9. A

    Parallel glowworm ultracom wiring

    Hi thanks for taking the time to read. I am myself a heating engineer for the last 13 years, but I have come across something new. the scenario is I have 2 ultracom 24hxi piped up in parallel. No problem. 1 pump and zone valves. All work fine as is, have been running on 1 boiler for the last...
  10. B

    glowworm CI35

    has anyone got a manual for the above glowworm 35 ci the one on the my boiler .com does not work it just errors.been to it today its intermittently not working - its sparking but no gas to burner there is 6 wires to gas valve stepper motor anyone any ideas what voltages are on these and is the...
  11. R

    Free Glowworm training in Bristol

    Free boiler training in Bristol Dear One of the great benefits of being a member of Club Energy is that you can benefit from free training, as well as a 25% discount on any BPEC training being held. Our Bristol Training Centre of Excellence has the following free course happening next...
  12. A

    Glowworm help

    Can any one here that's actually done any work on the Glowworm ECO scheme get in touch with me. And does anyone one know who the local rep for the Manchester area is?
  13. A

    Condenste Pump Glowworm Flexicom 30cx replacement

    I may have posted this in the wrong thread a moment ago:Hi, the condensate pump on my Flexicom 30cx has packed in (I'm pretty sure it is that as the reservoir fills within a day or so and if I empty it, it all works ok again for a day).Can I get a suitable pump that is not supplied by Glow-worm...
  14. A

    Glowworm Flexicom 30cx new pump needed-please help

    Hi, the condensate pump on my Flexicom 30cx has packed in (I'm pretty sure it is that as the reservoir fills within a day or so and if I empty it,it all works ok again for a day).Can I get a suitable pump that is not supplied by Glowworm (very expensive) and fit it myself?Money is tight just at...
  15. stani

    Glowworm galaxie

    Does anyone have a set of Mi's for the Glowworm galaxie, that is how it's spelt but not sure if that is just the fire front or the Bbu.
  16. A

    new glowworm betacom

    has anybody else had trouble with the PRVs when installing the current Betacom the pipework screws up into a plastic fitting, metal to plastic is never a good idea but in this case the plastic seems to be particularly soft and easy to thread a coleague had problems a months ago and i had the...
  17. J

    Glowworm Micron 50ff

    Hello everyone, I have been asked to repair a Glowworm micron 50ff boiler. The boilers reset light is illuminated and the burner indicator light is flashing on the fault finding chart this indcates softwaree problem. The boiler is othwise not working. I suspect the PCB is us. This happened after...
  18. R

    Boilers to clear - Glowworm 18 SX & Worcs 24i Junior

    Hi All We have discovered a couple of boilers with problems that can't be sold as new, but may be of interest to a bargain hunter who doesn't mind putting a bit of effort in. The Glowworm Flexicom 18 SX system boiler has been hung on a wall, but not used. The template is torn and scruffy, the...
  19. P

    Glowworm 50B FF fault

    Hi all, Hopefully someone will be able to point me in the right direction> I have a boiler fitted to a koi pond via a heat exchanger and i cant get it to fire. Ive followed the fault finder suggestions but it still won't work. The problem is when its turned on the pump starts, the fan starts...
  20. B

    glowworm betacom 2

    fitted one of these today could not get the pressure display to stay on when fitting as soon as you get to .5 bar the pump runs the pump purge .anyone fitted many of these and knows how