high | Page 8
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

high

  1. L

    ravenheat high flame cutting out

    hello need some help ive had the fan and air pressure switch replaced on my reavenheat. 85 cs but high flame the flame cuts out ?
  2. P

    Halstead ace high problem

    Hi I looking for some help with my boiler......it would only give me hot water when the heating was on and after looking on line i found that the problem was likely to be the diaphram in the flow valve. I changed the diaphram but still had the same problem so i changed the whole valve unit...
  3. P

    Halstead ace high problem

    Hi Im looking for some help with my boiler...it was running fine untill a week ago when i stopped getting hot water...i found i could get hot water with the heating turned on and looked on line and found a lot of people mentioning the diaphram in the flow valve....i changed that and still no...
  4. C

    High pressure on highflow 400

    Hi i currently have a worchester highflow 400 rsf combi. The past 6 weeks the overflow pipe been dripping water, I've checked the water pressure and this was up to 3 bar. I've had the expansion tank replaced twice (first one was faulty) but the pressure is still high. ive changed the heat...
  5. P

    High gas pressure...

    I'm sure im preaching to the converted but just a reminder that the low pressure tier goes up to 75mb and it is quite possible to see elevated pressures on low pressure services so if you use a water guage, you may well find that the water disappears over your shoulder when you turn the ECV on...
  6. C

    Low water pressure High bills. HELP!

    Hi guys. First off i am not a plumber although i have a little experience with heating systems etc. To the point: I have a combi boiler (around 14 years old) I can not pressurise the system though. The mains pressure has been tested by scottish water and with a secondary pump was clocked at...
  7. E

    High Co levels 400+ on 28i RSF combi

    Hi am getting extremely high CO reading, using test point that connects to fan via silicone tube as vertical flue fitted, new fan fitted by other last year so could be that not sealed/missing gasket, or flue gaskets as everything else as Mi's Burner removed and cleaned etc. Going back tomorrow...
  8. R

    High water consumption

    My building is using 3 times the amount of water it should. I have had the water meter changed. I have checked every riser for leaks. Plant is not losing water all overflow pipes visible. Had every meter checked for other flats and businesses within our block. No one stealing our water. No...
  9. P

    Halstead(i get all the best jobs haha) ace high - hot water is fine, no heating....

    Hi Guys, I thought I would be best off asking for this one in lieu of the wealth of advice on here. I have a landlord with a halstead ace high combi, boiler fires and stay on all appearing to run fine, no noise, no over expansion. However when heating is switched on pump runs, fan runs...
  10. P

    Any ideas of how to remove the nut on a high level WC cistern

    Hi I have been unsuccessfully trying to remove this nut to release the syphon from a high level cistern. The pipe is plastic so I cannot heat up the nut. I have tried freeze it spray which usually works but not on this occasion. Any ideas?
  11. S

    Double check valves and high water pressure

    Came across a few Double check valves failing recently. Washing machine no water errors and outside tap with long hose connected same no water. Remove hose and open tap water flows ok. Re-connect hose ...no water. No blockage, no kink. Replaced washing machine valve to one without check valve...
  12. B

    Worcester high flow 3.5 pilot light problem

    Hi, i have the above boiler. Ch been off for 6 moths. Hw activated on demand. With hw on Boiler making a occasional banging noise which seems to be resolved after activating CB and bleeding both ch zones. Now pilot light seems to go out and needs manual relighting. Thinking perhaps air...
  13. JCplumb

    Basin mixer, high cold pressure, 0.5 bar hot (gravity HWS)

    Got a customer who has called me in after an absolute nightmare with a cowboy builder and an ex-friend project managing her renovation. I feel really sorry for her, she was actually crying when explaining what had gone on when I first went round. Anyway, she has a basin mixer that she really...
  14. S

    High pressure in heating system and constantly filling

    Hello, Around 3-4 weeks ago I noticed the TPV overflow pipe at the back of the house was dripping and the system pressure had increased to 3 bar. I bled the radiators (no trapped air) and then ran off some water from a downstairs radiator. Initially this did the trick and the pressure dropped...
  15. P

    Which high flow combi setup?

    For reasons I won't bore you with I cannot have an unvented system so am looking at having a storage combi installed. My mains has been upgraded to 32mm and when the new boiler is installed the current 15mm running into my house from the mains will be upgraded to 22mm. My house is a normal...
  16. B

    Baxi 105HE high emissions

    Getting high emissions on a Baxi 105HE, a full strip down has been carried out but then found that the secondary heat exchanger seal behind the plastic connection had failed and was leaking condense back in to the boiler. So, I replaced the entire secondary heat exchanger today but still...
  17. N

    vokera linea 24 boiler High water pressure problem Help please

    My boiler is over pressurising, and venting out of the PRV outside (Continually dropping) I have replaced the PRV and checked the expansion vessel that needed topping up. I did notice that when I had toped up the Expansion vessel that the water gauge when up to the pressure that I had put into...
  18. H

    Gravity Fed System - upgrade to Combi/ High Pressure System

    I currently have a gravity feed system. In the very near future I am adding a loft extension to my property so the 2 cold water tanks in my London roof will have to be removed. I seek a plumbing/engineer to visit my property to give me advice and possible options in upgrading my existing...
  19. A

    High level cistern question

    The wife in her infinite wisdom has decided she wants a high level cistern. As the standard height is 2.3 ish metres and the room is 1.9 my question is can the flush pie be trimmed this much without affecting the flush too much? The cistern is a 3/6 L dual flush.
  20. U

    High level cistern problem

    The wife in her infinite wisdom has decided she wants a high level cistern. As the standard height is 2.3 ish metres and the room is 1.9 my question is can the flush pie be trimmed this much without affecting the flush too much? The cistern is a 3/6 L dual flush. Cheers
Back
Top