logic | Page 3

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

logic

  1. S

    Inconsistency in logic for extractor condensate

    One of the reasons I have seen for not routing the condensate from an extractor fan outlet into the soil stack (at a point above all sinks/toilets/etc that drain into the stack) is that smells would come from the stack into the room containing the extractor fan. I can see the logic in this but...
  2. J

    Ideal Logic Combi 24. Water is perfect for bathing a baby but not for shaving.

    Good Evening from sunny Clevedon. Heat Exchange was changed 1 year and 13 days ago. I fitted a new no flow thermister, which I was told would be the main suspect but has made no difference. Any advice ? I have a big pan on the boil all the time for shaving and doing the washing up but I rather...
  3. king of pipes

    Ideal Logic 24 kw mk1

    6 th time I've serviced this boiler I fitted 7 years ago not missed a beat had to change the burner gasket and spark electrode gasket today other than that it's still all original and in good condition. 😬 Kop
  4. king of pipes

    Ideal Logic suprise

    Had a strange thing happen on a routine service yesterday chaps got it sorted. Kop
  5. L

    Logic combi 30 HW not firing up.

    My Logic Combi 30 Boiler was working fine. Whilst servicing it, the hot water stopped firing up although the heating still works. . Engineer said these cheap boilers often do this when turned off and back on again and now it needs a flow something. Is this correct please? He also had a leak...
  6. M

    Ideal Logic L3

    Hi lads any of use ever come as an L3 on a logic? Nothing at all in the book about it just all pointed towards board when I was there, swapped it inc code plug, swapped thermistor whilst I was there and all that's done is I can now run just hot water for about 15 mins ... before it was heating...
  7. C

    Ideal logic plus and halo room stat, check serial number first

    morning as told by my local ideal rep if the boiler has a serial number earlier that AFQ meaning it was manufactured on June 2019 or before you will be unable to use/bind the new Halo combi stat
  8. ShaunCorbs

    Idea logic ho

    Am I missing something? uou can’t get the trap out unless you remove the sump ?
  9. R

    Ideal logic combi 24 no hot water

    Gas engineer here. Been to an ideal logic combo 24, (the older model with brass manifolds either side) customer complained about temperamental hot water. Did the usual checks solid red light on hall sensor diverter head ok diaphragm springs back return thermistor above pump ok thought it must be...
  10. R

    IDEAL LOGIC COMBI 30, hot water not very hot

    IDEAL LOGIC COMBI 30, hot water not very hot, water flow fine. Would I be right in that the diverter valve cartridge needs replacing. Any other suggestions
  11. fronty

    Ideal Logic combi cycling when CH hits 50

    Hi, my Mum's Ideal Logic combi keeps cycling when the temp reaches 50 degrees despite the CH control set to max. The manual says the flow temperature should reach 80 when set to max but I can actually hold the CH feed pipe with my hand and it never gets hot enough to cause me to let go before...
  12. J

    Ideal Logic Combi ESP1 30 SE code

    Hello I'm struggling to understand this code as I cant find it in the User Manual. The display has an SE code with a spanner in the top left corner. I am not able to change the water (40 degrees)or central heating temperature (30 degrees). Does anybody know what this could be? Thanks
  13. C

    logic combi 30 replacing bath tap

    Hi, I need to replace a bath tap but the taps don't have any shut-off valves, I can do the cold water but not certain how to do the hot. My boiler is a logic combi 30 pressurised system, how do I stop the water from flowing while I replace and will I need to fill the system again. Thanks
  14. M

    Ideal Logic Problems

    Hello I have a Ideal Logic Plus Combi which is approx 2 1/2 years old. I am waiting for the Gas Engineer to come out but in the meantime would like to have some idea what might be up with my boiler. There are a 2 main issues and i don't know if they are related. Firstly the hot water only gets...
  15. D

    Pressure issues Ideal Logic Combi 30.

    Hi, we have an ideal Logic combi 30 and have an issue with the system loosing pressure. We have had an engineer look at the system twice without being able to find a fault. I isolated the boiler last week to determine it was the boiler and not the rest of the system. When the system was warm...
  16. M

    LOGIC COMBI 24 EXTERNAL PIPE LEAKING

    Hi all, Boiler has been losing pressure for overnight for a couple of days. Was at a loss, but have just found this on the pipe loop outside of the house in line with where the boiler is sited. What is its purpose? Second pic is where I presume the pipe comes from. It connects to the very Last...
  17. D

    Whistling noise coming from Logic Combi 30 boiler upon ignition.

    Hello all. I had the annual service for my Logic Combi 30 boiler back in November and all was seemingly fine. However since the colder weather has really begun within the past few weeks we have had the heating on more and at a higher temperature (22.5, up to 24 degrees on occasions). As the...
  18. D

    Logic Code Combi (issue?)

    Hi all First timer here - after reading a lot of the advice present I thought it would make sense to get stuck in and throw something into the ring. I am a Landlord and Agent operating new build properties in the Nottinghamshire areas, and have what seems to be an ongoing problem with one...
  19. M

    Logic combi

    Ideal logic combi Anybody had issues with the bottom of heat exchanger blocking - first thought was air/ gas ratio ,but found when removing condensate trap completely including rubber connection elbow noise on initial fire up stopped ,as boiler was getting air it needed, flushed with boiling...
  20. king of pipes

    Ideal logic 24kw heat

    A routine vist to service this boiler a first time for me, turned into a bit of a nightmare as you can see below a small hole had appeared in the plastic flue part that takes the condense away made a right old mess in there i did a temporary repair job and serviced a full safety check it all...
Back
Top