Hi,
Please I need some advice.
I've got a mega flow presurised cylinder, heated indirectly with by a gas boiler. I also have Solar PV with an iBoost. In summer I get v. hot water ~75 c.
I wanted to put a TMV on the output of my ho****er tank, but want to know if anyone has experience on the...
Hi,
A few days ago I was getting a tiny water leak on my Range Tribune HE hot water cylinder, i called a plumber, he ascertained the immersion heater was faulty (corroded) and needed to be replaced. He told me afterwards there's no drain off tap on the cylinder so he pulled the immersion coil...
Hi. Im new so please bear with me. I will try to explain in as much detail as I can. I have a fairly large 3 bed house. We have a standard gas boiler downstairs (not combi) with an unvented water system upstairs. We have the main water tank with the red expansion vessel which is located just...
Hi,
Im about to replace my vented indirect hot water cylinder for a larger one due to lack of hot water. I have bought an identical cylinder, ie vented and indirect but larger in size and i have noticed a couple differences. 1, on all the connections i was expecting them to be external threads...
Hi,
Im looking to change the indirect hot water cylinder in the loft from a 900 x 375 to a 1500 x 450. Reason being is ive had enough of the mrs's complaining the hot water keeps running out when she uses the power shower!!!! Is there anything i need to be aware of when making the change from 1...
I need to temporarily disconnect the boiler from an old IMI Range Primatic cylinder and cap off the connections so the electric immersion can be used instead while the boiler is sorted.
I bought a couple of 28mm nuts and blanking discs but the boiler outlet/inlet fittings on the cylinder...
Hi I was wondering what does the 3 T rule mean when you install a hot water cylinder ? I'm guessing it has something to do with the pump : I mean where the pump has to be installed.
Looking forward for an answer as I have never heard about it before.
regards ronny
Hi, I'm after a bit of advice on this part please. I'm looking to replace the connection to the lower central heating point on my cylinder. The bolt itself measures 1 1/2" with 22mm pipe coming out of it - presume also that it's a bolt with a male thread.
Can anyone confirm if this part will...
Evening guys, Need to replace a 1200x450 combi hot water tank which has had its day. Any idea the best place on getting one? Standard tank with two elements. thanks guys
Hi,
I'm looking for a price to supply and fit a replacement Economy 7 cylinder (mine is leaking). In GU6 area (Cranleigh, Surrey which is ~15 mins from Guildford / ~20 mins from Dorking or Horsham). Will require replacement of the plywood board it sits on as the wood looks like it's rotten...
Three years ago I installed a new 50 gallon cold water tank in my loft on a platform 54 inches above the ceiling and a new stainless steel 140 litre hot water cylinder which had 22mm welded flanges for inlet and outlets.
I then built a shower room in a spare bedroom fed by a Salamander...
I have an oil fired system boiler driving a hot water cylinder and radiators through a Honeywell three port mid position valve. Before that we had a Worcester boiler, through a Danfoss mid position valve.
Problem is loud humming/vibration through the pipes around the cylinder, loud enough...
Please I need the advise of an experienced plumber on how to install a NEPTUNE 150L DIRECT UNVENTED S/S CYLINDER that I purchsed from Kingspan.
Thanks all.
I have an Albion MD16 copper hot water cylinder with a pin hole leak at the base. This in a vented, indirect system, with approx 8 metre water head. The cylinder has 10 mm insulation, and is 910 mm tall. I wonder if its dimensions are Imperial. I doubt like-for-like replacement is possible.
I...
Hello guys,
This is my first post so apologies in advance for any of my ignorance.
I have got 2 vented 105 litres in-direct hot water cylinders installed, out of which I would like to isolate 1 to save cost in heating both. All I wanted to know if the steps below are right to isolate it.
1...
Morning Guys.
After some help/advice.
We we have recently moved into a rental property with the following set up ....
- Ideal Logic heat 12 boiler (Kitchen)
- Danfoss dual CH and HW electronic controller (under boiler)
- Range Tribune HE Cylinder (Airing Cupboard)
For some reason the...
Hi,
Which unvented hot water cylinder would you regard to be the best?
If I had an unvented hot water cylinder would I still need to have a separate mains water booster? My house is 10 years old and I live on a new street.
Thanks!
hi guys iam after a new cylinder whats the best to get copper or stainless steal also whats the going rat to replace cylinder labour thanks anyone in devon
Hello
I would be very grateful on some advice on the following issue. We had a vented direct hot water cylinder fitted (with requisite cold feed tank etc) to feed our new Mira pumped digital shower (already have a combi fed, but need to run two showers at once, not enough mains pressure for...