fire | Page 7

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

fire

  1. A

    Fitting wall hung gas fire after Bermuda removal

    Hi cust wants new wall hung gas fire once his boiler is done, I've told him let me sort boiler then once back boiler and fire is gone I'll have a look. money is definitely an issue now he is having the boiler done. Anyone fitted a fire after removing a back boiler? Any advice on best way to go...
  2. C

    open fire and oil boiler

    is It possible to connect to a open fire already installed to feed gravity hot water and pumped heating , a conventional oil boiler boiler, its in my own house, never done it before , asked some other plumbers and they said that you can do it with a 3 port valve , there must be a way to do it...
  3. L

    URGENT- Help - Need to know the Output of this Fire (kw)

    Excuse the 1st question of mine asking for help. Tried searching the net to no avail. Need to know if this Gas Fire is requiring an Air Vent if we decide to go for cavity wall insulation. Apparently if its over 6 kw then we need ventilation. Much appreciate any assistance. Lozzer
  4. P

    When is a room air vent for flame effect gas fire really needed (with BS)

    Some history is that one gas engineer (who checked safety after fitting of a new gas meter) in the past said I had to have an air vent fitted in the lounge as gas fire required it, but then another engineer (British Gas) said if it is 7½ bar & below this is not necessary, so blocked the said up...
  5. AlexGas

    Plumbers escape after van catches fire...

    Plumbers escape after van catches fire in Southend street (From Echo)
  6. D

    Potterton 70 HE fire up problem

    First of all a Merry Christmas to all The boiler will start ok from cold but once it's been running a while it goes into the start up sequence with the pump and fan cutting in and then immediately off and keeps repeating this process until it eventually starts up. Both or either MRV's are...
  7. S

    Grant vortex eco utility 15-21 will not fire and there is water dripping from a few p

    I have got up this morning to a cold house and noticed the boiler was making a noise but was not firing, the oil tank is 3 quarters full and it worked perfectly the night before. The pressure gauge is reading 2.5 bar and the lockout switch is not illuminating. There is water dripping from a few...
  8. R

    Baxi Eco80 wont fire CH unless i turn on DHW tap

    I have an interesting problem with Baxi Eco80 boiler which i inherited when i moved into my flat a few month ago. At first i thought it was the thermostat so i recently replaced it with a 3rd Gen Nest. However its evidently not the thermostat. Problem occurs when the boiler has been idle...
  9. R

    Baxi Eco80 wont fire CH unless i turn on DHW tap.

    I have an interesting problem with Baxi Eco80 boiler which i inherited when i moved into my flat a few month ago. At first i thought it was the thermostat so i recently replaced it with a 3rd Gen Nest. However its evidently not the thermostat. Problem occurs when the boiler has been idle for...
  10. N

    Does anyone have experience of open fire back boiler plumbing?

    Hi all, wonder if there's a tradesman on here who has experience of open fires with back boilers. Just moved into A 1980's semi in a rural area, which has a traditional open fire. It obviously has a back boiler as there is a damper. There's a box-in at the side of the chimney breast. Two 22mm...
  11. M

    Fire resisting supports in escape routes

    Hello Please can you help a sparks we are not allowed to install cables in a fire route without metal supports, due to risk of firemen getting hurt after a fire etc. Is there any regs similar for plumbers? 521.11.201 Wiring systems in escape routes shall be supported such that they will not...
  12. J

    servicing a gas fire

    Hi all, I've got a theoretical question about servicing gas fires. When you take the gas fire out of the chimney (to do the smoke test, etc), do you routinely dismantle the pilot/burner pipes and injector and clean them as well? By blowing compressed air through the dismantled pipes? The gas...
  13. A

    Radiant gas fire

    Signs of schorching on carpet below wall hung gas radiant fire classification at risk?
  14. R

    Bird can fly into chimney serving open-vented gas fire!

    Is it usually considered acceptable for an open-vented gas fire (by which I mean one which vents its exhaust gases up a chimney by natural draught) to have a terminal that will allow a bird into the chimney? Got a phone call from my mother yesterday. She's not going to be able to meet me...
  15. R

    really need help on this fire!

    fitted an oxy-pilot on this fire back in march and the fire wont light again! supplied and fitted a new one and the fire still wont hold flame? the customer is giving me some real verbals for a job we did for free as part of a bigger job (only charged part price, you learn:yesnod:) now he said...
  16. M

    Power Flue Gas Fire - Lost Efficiency and Heat Output

    We have a Kinder Kalahari Power Flue Gas Fire which has a rated maximum heat output of 3.3kW. We inherited the fire three years ago when we moved to this house and the fire used to give off a good amount of heat. This was demonstrated by our dog getting so hot that he'd have to move to a cooler...
  17. Stanios

    Multipoint on fire

    Hi, got my badge thank you AP! My first post in the yellow badge area might seem abit silly but here it goes: Brittony 2 multipoint, burners producing flames out of places it shouldnt including large yellow ones going outside the heat exchanger i.e burning the case. Gasket that joins onto...
  18. Stanios

    Multipoint on fire

    First off Im gas safe Croppie gimme badge already! Just a quick one -Brittony 2 multipoint, burners producing flames out of places it shouldnt including large red ones going outside the heat exchanger i.e burning the case. Gasket that joins onto the burners has something that looks like loctite...
  19. D

    oxypilot problem on focal point fire

    i have an Ashleigh plus focal point gas fire , the pilot light only lights out of the hole that points onto the thermocouple , the hole that points to the gas burner under the coals doesnt light on ignition . This means the fire lights with a " woosh" when the gas finally ignites , and when the...
  20. S

    fire hose reels

    Trying to trace a cold main on a commercial refurb,gaffers away so on my todd for a few days,had nothing to with fire reels,2 questions,can you fit them in a building fed on a cold supply fed from plant room boosted cold feed,as at moment they are fed on the mains,but they want booster sets fitting.
Back
Top