logic | Page 6

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

logic

  1. A

    Logic Combi 35 low water pressure.

    Hi, I keep getting a F1 fault on my boiler for the last 6 months. Easy to reset to get my water and heating going again. Over the last week I’ve had water coming through the ceiling in my downstairs toilet. The paint is bubbling away and it’s in a straight line across the whole ceiling so I’m...
  2. R

    Problem with logic 35 water part 2

    Evening gents First off thanks for everyone who contributed on my first post. I’ve had a engineer out to look at the problem who spoke to ideal technical and he thinks it is either the heat exchanger or the diriviter valve. He is coming back with prices, although he did mention sometimes it’s...
  3. king of pipes

    Who does this on a logic + service

    This one got missed last year so full strip flush through the heat ex new electrodes and gaskets good for another year . Cheers kop
  4. D

    Ideal Logic 30kw boiler

    I'm in the market for a new boiler. Been recommended the above boiler by an installer. Is it any good or should I stick to Bosch Worcester?
  5. R

    Problem with hot water on logic combi 35

    hi Gents We are having issues with constant hot water flow with the above boiler. The boiler was serviced over a year ago and had the same issues , at that time the plumber thought the issue was the thermistors and they were changed. This seemed to help the problem but did not cure it and it...
  6. shaky

    Flow sensors ideal logic heat only

    Hi all how do some of you test flow sensors on an ideal logic Plus heat only boiler? Some boilers just 2 wire but the logic has a 3 wire sensor Thanks,
  7. Jock Spanners

    Ideal Logic Combi - Low Working Pressure

    Evening all, I've been to service an Ideal Logic Combi 30 today and when I tested the working pressure at the inlet it was only 10mb on maximum rate. The WP was 20mb at the meter. The analytics were spot on and the gas rate 3m/hr. The pipework is correctly sized and there doesn't appear to be...
  8. I

    LOGIC COMBI 30 BOILER PROBLEM

    The last few days noticed my upstairs radiators are heating up when any taps are turned on , could this be down to a valve not shuting properly . Anyone got an idea of the cost if its a valve needing replaced. Thanks Ian.
  9. P

    Ideal Logic Combi 24 problem

    Hello I am a plumber but not a gas safe plumber . I have recently changed a shower room into a bath room in my niece's house. The job went well but now we cannot get any hot water out of the boiler to any of the taps. This despite the fact that the heating is working. I have done nothing to...
  10. T

    Advice on buying Ideal Logic for my house

    Other than £75, whats the difference- Basically, which would you buy? I was going to order the cheapest on Monday Ideal Logic ESP1 24kW Combination Boiler Natural Gas ErP | Boilers Ideal Logic C24 Combination Boiler Natural Gas ErP | Boilers
  11. G

    Logic Combi 35 - constantly on regardless of thermostat settings

    Hi all, Just before Christmas I had an issue with my Logic Combi 35 whereby it was constantly calling for the central heating to be on. Even with my room thermostats set to 18 degrees, it was still heating the house to between 21 and 23 degrees. The only way to make the heat bearable was to...
  12. E

    logic plus combi no hot water or heating

    logic plus combi boiler I have no hot water or heating I have reset the boiler turned both dials off {water and heating} and turned both dials back on still nothing but each time I have switched them back on I keep getting a bubble noise
  13. N

    Ideal Logic gas valve fault

    Hi guys came across a strange one today and was wondering if anyone could shed some light cheers. Had a report of noise coming from boiler. Arrived on site and found when gas valve modulated to minimum rate it the diaphragm would vibrate and sounded like the titanic was arriving through the...
  14. P

    ldeal logic + 30kw combi

    ideal logic combi losing pressure daily. Initially i thought it was a leak on the system so all the pipework was checked and no leaks found The flow and return were isolated overnight with no demand and there was a pressure drop. I disconnected the condensate pipe and put a bucket under it but...
  15. D

    How do I start the heating without my thermostat (iIdeal logic combi 24 with prt2 thermostat)

    Help! I have a iIdeal logic combi 24 with prt2 thermostat. I've broken the thermostat and now it will not communicate with the boiler. How do I start the heating without the thermostat. The house is freezing and my pregnant wife is about to murder me.
  16. B

    Ideal logic ignition electrode gaskets

    Hi Just wondering if anyone knows if there is a replacement gasket for the ideal logic ignition electrodes without buying the full electrodes at £20 Noticed allot start to fall to bits after a while when servicing them. Also why's one graphite and one fiber. Thanks
  17. J

    Unconfigured PCB on ideal logic combi 30

    New member here. And I would appreciate some help re my ideal combi boiler. I have no water heating and no central heating working and getting F9 as the status in the boiler which according to the Manuel is an unconfigured PCB. I’ve tested the fuse and it was fine. I just wanted to ask would...
  18. J

    SAP says ideal logic combi and electric shower in 3 bed semi with 2 baths. Will it work?

    Hi, I'm a house builder and am putting together a spec for some new build semis. They're 1200 sq ft with 2 bathrooms, one main with shower of bath and one ensuite with just shower. A system boiler and tank means I fail the SAP test without some other expensive alterations. If we have a this...
  19. B

    Ideal Combi logic 30 F1 error

    Hello Yesterday I noticed that the boiler is displaying an f1 error. I have bled all radiators and checked the pressure, it is just above 1 bar. Can anyone suggest what else I could try please. Thanks in advance
  20. D

    Ideal logic combi 30 problems

    hi all Seem I've had a few problems lately with this little gem of a boiler, she's about 7 years old. Usual issues, pressure dropping, needed topping up every 3-4 days Not visible leaks detected. Then the hot stopped working so I changed the flow turbine which solved the problem also while I...