  1. T

    Are kitchen sink apertures a standard size?

    We have a one a half bowl sink in a standard 100cm base unit. We want to replace the sink with a new one a half bowl sink in the same worktop. How likely is it that the new sink will fit in the same aperture with little or no cutting?
  2. A

    Shower waste - what size pipe?

    Hi, I have a new shower tray to install that has come with a shower waste trap with 40mm output. The waste needs to run around 3.5m to 4m before connecting to vertical soil stack. I understand building regs require 50mm pipe to be used for this length of run? Do I therefore need a new trap with...
  3. dilligaf

    Can anyone tell me what size fitting this is?

    I bought a vacuum pump from ebay and I'm not sure what size the threaded adaptor is. I want something to convert it to fit a 1/8 bsp female tee piece which will fits my gauge as well. I tried to see if the 1/8 bsp tee piece would screw onto the pump but not quite and the threads are different...
  4. M

    What size lead lock to use

    Hello, I have a length of lead pipe to a garden tap. The lead pipe has been sweated to copper and this 15mm copper is connected to the tap. There is a leak in the lead pipe and I want to cut the lead pipe below the leak and to add a lead lock to connect 15mm copper to up to the tap. I believe...
  5. T

    Gas meter size advice before boiler swap.

    Hiya guys not been on in a while. I've picked up a little boiler change job for a chinese take away. The gas for the home above the takeaway is run from the same meter as the commercial kitchen, evidently before the interlock for the ventialtion. now I'am not a commercial catering engineer...
  6. E

    Quick kicthen sink measurement and size question

    Just wondered if I could have some quick advice re kitchen sink measurement as I want to be sure I buy the right sized replacement sink. I see that sink widths and lengths come in standard sizes, but when I measured my sink it falls between two of these standard sizes - i.e. 98.5cm length by...
  7. L

    THREAD SIZE FOR SHOWER/BATH MIXER

    I have currently a 10 yr old plus Thermostatic Bath Shower Mixer Model No: CD 324. Centre to centre of inlet is 180mm & full spec & dimensions are in this link: Nuie | Taps | Bar Showers | Thermostatic Bath Shower Mixer -...
  8. S

    What size tap is this?

    Hi, I am trying to fit a hosepipe to this tap (photo attached). I bought a 3/4 female adapter which is too big for the tap. I tried a 1/2 adapter too (shown on photo) but it is a fraction too small for the tap. Any advice welcome! Thanks
  9. G

    Service valve leaking, odd size

    Hi there, The service valve on the water line, for the cistern, is leaking. Struggling to find a replacement as it seems to be an odd size, 15mm compression fitting and 3/4 inch screw on, on the other side. Anyone know where I can get one? Google searches coming up blank.
  10. P

    22mm Fitting, thread size please ?

    Hello. Could anyone please advise ? What is the thread of a standard ( as used in UK ) 22mm compression fitting ? It appears to be 14 tpi but is slightly larger than 3/4 bsp. Thank you, Pete.
  11. K

    newcombi-boiler size in doubt

    just fitted a gloworm 24 kw into a flat with 6 rads one bathroom previous boiler were a 42 kw floor mounted ancient Worcester . client wanted wall mounted new boiler, only problem now is the flow rate too much for the boiler and full the water is luke warm did think of reducing the flow but...
  12. B

    New Kitchen Waste Run Correct Pipe Size

    Hello PFM's, I have the pleasure of doing my first waste run for a new kitchen installed in a flat and was hoping for some advice. I need a 6-metre run to the stack where I am going to mark my 1:40/1:110 and split the difference at a 1:80 gradient. It will be discharging the kitchen sink...
  13. A

    Air Release valve size for infra network.

    Hi all, I have more than 500meter potable water network line connecting to buildings, tanks say 25 branches which installed underground-main line starting from 125mm HDPE SDR11 to 40mm HDPE SDR11. What size of ARV to be used at ground level inside 600X600 ManHole.
  14. J

    Oil boiler size for large house

    Hi I’m looking to buy a new Combi oil boiler but don’t know what size to go for my old boiler was a Worcester heatslave 12/14 which was running originally 12 rads and one bathroom when I moved in. I then added a rad I believe it was to small to begin with as it was always breaking down it now...
  15. M

    Size of shower proformer in Wetroom - does size matter.

    Hi, I'm looking to change my downstairs bathroom to a Wetroom. It's currently an enclosed shower with a wooden floor on joists. I'm going to have the wooden floor remove and a Wetroom installed with a tiled floor. Please see picture of upstairs bathroom showing large tiles on the floor and...
  16. J

    Thermostatic Rad Valves, odd size Tails

    Hi first post here😀 I want to replace a couple of rad valves with TRVs but as you can see from the pic, the existing tails are bigger than it usual. All the valves I can find have 1/2” bsp Threads both sides, but I either need TRVs with one side to match the tails, or a reduced for the rad. Any...
  17. Stigster

    What size are the connections on these valves?

    From a thread where I've been helping someone with radiator valve problems. Looking at the pictures of thes towel rail valves I'm not 100% certain what size the connections are. Pretty sure it's 15mm coming in to the valve but is the rad-side connection 1/2" with a fat nut or 3/4"? If anyone...
  18. N

    Waste pipe size query

    Hi, I have a basin trap that has a 35mm chrome waste pipe supplied. I was wondering if this can converted to standard 32mm pipe as the chrome isn't long enough. I seems odd that the Chrome pipe isn't a standard size? Thanks
  19. G

    what size cable for 8.5kw shower

    Ive got an electric shower to replace, currenty 8.5 kw on a 6mm cable. Is it dumb to install 8.5kw on 6mm, im sure i used to do this years ago without thinking too hard about it. A quick bit of research recommends 7.5kw max rating. what would you do? Rewire for 10mm too expensive. Cheers.
  20. T

    Unvented cylinder size

    Hiya guys I currently specing a job for a 5 bedroom house with x5 ensuites. Could anyone advise me on sizing cals for unvented cylinders. Thank you